1、E I A 3b2 b 9 3234b00 00b5933 2 9 r A N S I C83.56-1970 Approved January 22, 1970 American National Standards Institute HA STANDARD Recommended Test Method - Tensile Properties of Magnetic Tape RS-362 - Engineering Department ELECTRONIC INDUSTRIES ASSOCIATION Copyright Electronic Components, Assembl
2、ies however, serrated gips lined with thin rubber, crocus cloth or pressure sensitive tape may be needed for some specimens. Air-actuated grips are advantageous for materials that tend to “neck“ into the grips since uniform pressure is maintained throughout the test. 4.3 Specimen Cutter A device tha
3、t will give straight, clean, parallel edges with no nicks, uncut areas, or other imperfections shall be used for cutting the specimens to the proper width, where this is required. In most cases, the tape specimen will be tested in the width supplied. 4.4 Thickness Gauge A suitable thickness measurin
4、g device, capable of being read to 0,00002 inch (0.00050mm), shall be used for measuring the thickness of the specimens. Note: Where specimens of tape with a base thickness of 0.001 inch (0.025mm) or more are being tested a thickness measuring device capable of being read to 0.0001 inch (0.0025mm) m
5、ay be substituted. 4.5 Width Measuring Device A suitable width measuring device, capable of measuring to at least 0.003 inch (0.075mm) shall be used for measuring the width of the specimens. 5. CONDITIONS 5.1 All measurements shall be made under the following atmospheric conditions, 70 f 5F (21 k3“C
6、) 50 f 5Y RH Note: If it is anticipated that the tape will be used under conditions of temperature or humidity substantially different than the above, the measurements should be made under those conditions. 5.2 under which the measurement will be made. The specimens shall be freely exposed for at le
7、ast 12 hours to the atmospheric conditions , Copyright Electronic Components, Assemblies & Materials Association Provided by IHS under license with ECA Licensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/30/2007 20:06:37 MDTNo reproduction or networking permitted without license
8、from IHS -,-,- EIA 362 69 m 3234600 0065937 T m - RS-362 Page 3 6. TEST SPECIMENS 6.1 (1 75mm) long. The test specimens shall consist of strips of uniform width and thickness at least 7 inches 6.2 The tape specimens will be tested as received, subject to the following: a. inch (25.4mm). The width of
9、 the specimen shall not be less than 0.12 inch (3.0mm) or greater than 1.0 b. Tape specimens will be tested in the width supplied, subject to the limitations of step a. above. If the tape is wider than 1.0 inch, a specimen of suitable width shall be cut from the center of the tape. If the specimen i
10、s cut in a direction other than longitudinal, the direction of cutting shall be indicated in the report. The utmost care shall be exercised in cutting specimens to prevent nicks or tears which are likely to cause premature failure. Note: Microscopic examination of the specimens may aid in detecting
11、flaws due to sample or specimen preparation. c. specimen between the grips. The width shall be uniform to within +2% of the average width over the length of the d. within 10% of the average thickness over the length of the specimen between grips. Wherever possible, the test specimen shall be selecte
12、d so that thickness is uniform to 7. PRBCEDURE 7.1 Setting up film testing machine a. than one-third FSL. Select a full scale load value (FSL) such that the load at specimen rupture will be greater b. Set the rate of grip separation at 2.0 inches per minute (50mm per minute). Note: When testing tape
13、 made of film whose tensile properties are known to be strongly dependent upon the rate of elongation, the rate of grip separation used should be selected to simulate as closely as possible the rate of strain to which the tape may be subjected in use. c. Balance, zero and calibrate the load weight a
14、nd recording system by the methods described in ASTM E4. 7.2 Verifying width, thickness measuring devices a. Calibrate the thickness measuring device by the methods described in ASTM D374. b. Check the calibration of the width measuring device. Copyright Electronic Components, Assemblies & Materials
15、 Association Provided by IHS under license with ECA Licensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/30/2007 20:06:37 MDTNo reproduction or networking permitted without license from IHS -,-,- E I A 362 b m 323Vb00 OOb5938 I m 4 RS-362 Page 4 7.3 Measuring width of specimen a M
16、easure the width of the specimen at several points along its length to the nearest 0.003 inch (0.075mm). Compute the average of these values. Record the average width, rounded off to three significant figures. Check that the individual measurements are within +2% of the average value. 7.4 Measuring
17、thickness of specimen Measure the total thickness of the specimen at several points to the nearest 0.00002 inch (0.00050mm). Check that the thickness is uniform to within 10% of the average thickness. Note: Where specimens of tape with a base thickness of 0.001 inch (0.025mm) or more are being teste
18、d they may be measured to the nearest 0.0001 inch (0.0025mm). 7.5 Obtaining the load-extension curve a. Set the initial grip separation at 4.0 inches ( I OOmm). b. Place the test specimen in the grips of the testing machine so that it is centered in the grips with its long edges parallel to an imagi