ECA-EIA-364-111-2008.pdf
《ECA-EIA-364-111-2008.pdf》由会员分享,可在线阅读,更多相关《ECA-EIA-364-111-2008.pdf(20页珍藏版)》请在三一文库上搜索。
1、 EIA STANDARD TP-111 TEST PROCEDURE FOR DETERMINING THE TOTAL IONIC CONTAMINATION OF AN ELECTRICAL CONNECTOR OR SOCKET ASSEMBLY OR COMPONENT EIA-364-111 DECEMBER 2008 ANSI/EIA-364-111-2008 Approved: December 11, 2008 EIA-364-111 EIA Standards Electronic Components Association Copyright Electronic Co
2、mponents, Assemblies & Materials Association Provided by IHS under license with ECA Licensee=Boeing Co/5910770001 Not for Resale, 01/31/2009 04:22:05 MSTNo reproduction or networking permitted without license from IHS -,-,- NOTICE EIA Engineering Standards and Publications are designed to serve the
3、public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards a
4、nd Publications shall not in any respect preclude any member or nonmember of EIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than EIA members, whether
5、the standard is to be used either domestically or internationally. Standards and Publications are adopted by EIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, EIA does not assume any liability to any patent owner, nor does it assume any obligation
6、 whatever to parties adopting the Standard or Publication. This EIA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the EIA Standard and the IEC docum
7、ent can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulator
8、y limitations before its use. (From Standards Proposal No. 5164 formulated under the cognizance of the CE-2.0 National Connectors Standards Committee). Published by: ELECTRONIC COMPONENTS ASSOCIATION 2008 EIA Standards and Technology Department 2500 Wilson Boulevard Suite 310 Arlington, VA 22201 PRI
9、CE: Please call: Global Engineering Documents, USA and Canada (1-800-854-7179) http:/ All rights reserved Printed in U.S.A. Copyright Electronic Components, Assemblies & Materials Association Provided by IHS under license with ECA Licensee=Boeing Co/5910770001 Not for Resale, 01/31/2009 04:22:05 MST
10、No reproduction or networking permitted without license from IHS -,-,- PLEASE ! DONT VIOLATE THE LAW! This document is copyrighted by the EIA and may not be reproduced without permission. Organizations may obtain permission to reproduce a limited number of copies through entering into a license agre
11、ement. For information, contact: Global Engineering Documents 15 Inverness Way East Englewood, CO 80112-5704 or call USA and Canada (1-800-854-7179), International (303-397-7956) Copyright Electronic Components, Assemblies & Materials Association Provided by IHS under license with ECA Licensee=Boein
12、g Co/5910770001 Not for Resale, 01/31/2009 04:22:05 MSTNo reproduction or networking permitted without license from IHS -,-,- Copyright Electronic Components, Assemblies & Materials Association Provided by IHS under license with ECA Licensee=Boeing Co/5910770001 Not for Resale, 01/31/2009 04:22:05 M
13、STNo reproduction or networking permitted without license from IHS -,-,- CONTENTS Clause Page 1 Introduction . 1 1.1 Scope . 1 1.2 Object 1 1.3 Definition 1 2 Test resources 2 2.1 Equipment . 2 2.2 Material . 3 3 Test specimen 3 3.1 Description 3 3.2 Preparation 4 4. Test procedure . 4 4.1 Method A,
14、 Ionography 4 4.2 Method B, Ion chromatography 6 5 Details to be specified . 9 6 Test documentation . 10 Table 1 Common ions of interest . 9 i Copyright Electronic Components, Assemblies & Materials Association Provided by IHS under license with ECA Licensee=Boeing Co/5910770001 Not for Resale, 01/3
15、1/2009 04:22:05 MSTNo reproduction or networking permitted without license from IHS -,-,- (This page left blank) ii Copyright Electronic Components, Assemblies & Materials Association Provided by IHS under license with ECA Licensee=Boeing Co/5910770001 Not for Resale, 01/31/2009 04:22:05 MSTNo repro
16、duction or networking permitted without license from IHS -,-,- EIA-364-111 Page 1 TEST PROCEDURE No. 111 TEST PROCEDURE FOR DETERMINING IONIC CONTAMINATION OF AN ELECTRICAL CONNECTOR OR SOCKET ASSEMBLY OR COMPONENT (From EIA Standards Proposal No. 5164, formulated under the cognizance of EIA CE-2.0
17、Committee on National Connector Standards) 1 Introduction 1.1 Scope This standard establishes 2 methods for determining the total amount of extractable ionic contamination on the surface of an electrical connector or socket assembly or component. 1.1.1 Method A, Ionography A test method for quantify
18、ing the extractable ionic contamination on the surface of an electrical connector or socket assembly or component using an ionograph contamination measurement system as determined in sodium chloride (NaCl) equivalents. 1.1.2 Method B, Ion chromatography A test method for quantifying and identifying
19、the extractable ionic species on the surface of an electrical connector or socket assembly or component using an ion chromatograph system. Ion chromatography results are reported as parts per million as ionic species. 1.2 Object The object of this test procedure is to determine the amount of ionic c
20、ontamination that may be present on the surface of a connector or socket assembly or component (either plastic or metallic). The source of the contamination may be in the materials of construction or in residues from manufacturing processes. If excessive, the reliability of electronic equipment util
21、izing the connector or socket may be compromised. 1.3 Definitions 1.3.1 Total ionic contamination Soluble ionic species such as inorganic salts or weak organic acids 1.3.2 Connector or socket assembly Functional part consisting of conjoined components. Copyright Electronic Components, Assemblies & M
22、aterials Association Provided by IHS under license with ECA Licensee=Boeing Co/5910770001 Not for Resale, 01/31/2009 04:22:05 MSTNo reproduction or networking permitted without license from IHS -,-,- EIA-364-111 Page 2 1.3.3 Connector or socket component Individual piece of an assembly such as a hou
23、sing, a contact, a shield, a guide pin, a retention device, or other miscellaneous hardware. 1.3.4 Baseline Line where the test starts 1.3.5 NaCl equivalents Units of concentration of a species reported based on the equivalent weight of NaCl 1.3.6 Eluent The solvent used to carry the extracted ions
24、through the ion exchange chromatograph 1.3.7 Diluent Solvent used for dilutions 1.3.8 Column Analytical exchanger used in ion chromatography to separate ionic species 2 Test resources 2.1 Equipment The following equipment is required: 2.1.1 Method A, Ionography 2.1.1.1 Ionograph contamination measur