IEC-61076-2-107-2007.pdf
《IEC-61076-2-107-2007.pdf》由会员分享,可在线阅读,更多相关《IEC-61076-2-107-2007.pdf(36页珍藏版)》请在三一文库上搜索。
1、 IEC/PAS 61076-2-107 Edition 1.0 2007-12 PUBLICLY AVAILABLE SPECIFICATION PRE-STANDARD Connectors for electronic equipment Product requirements Part 2-107: Circular connectors Detail specification for circular hybrid connectors M12 with electrical and fibre-optic contacts with screw-locking IEC/PAS
2、61076-2-107:2007(E) Copyright International Electrotechnical Commission Provided by IHS under license with IECLicensee=IHS Employees/1111111001, User=Japan, IHS Not for Resale, 12/17/2007 18:42:26 MSTNo reproduction or networking permitted without license from IHS -,-,- THIS PUBLICATION IS COPYRIGHT
3、 PROTECTED Copyright 2007 IEC, Geneva, Switzerland All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or
4、IECs member National Committee in the country of the requester. If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information. IEC Central Of
5、fice 3, rue de Varemb CH-1211 Geneva 20 Switzerland Email: inmailiec.ch Web: www.iec.ch About the IEC The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related technologies. Ab
6、out IEC publications The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the latest edition, a corrigenda or an amendment might have been published. ? Catalogue of IEC publications: www.iec.ch/searchpub The IEC on-line Catalogue enables
7、you to search by a variety of criteria (reference number, text, technical committee,). It also gives information on projects, withdrawn and replaced publications. ? IEC Just Published: www.iec.ch/online_news/justpub Stay up to date on all new IEC publications. Just Published details twice a month al
8、l new publications released. Available on-line and also by email. ? Electropedia: www.electropedia.org The worlds leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions in English and French, with equivalent terms in additional languages. Also
9、known as the International Electrotechnical Vocabulary online. ? Customer Service Centre: www.iec.ch/webstore/custserv If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service Centre FAQ or contact us: Email: csciec.ch Tel.: +41 22 919 02
10、 11 Fax: +41 22 919 03 00 Copyright International Electrotechnical Commission Provided by IHS under license with IECLicensee=IHS Employees/1111111001, User=Japan, IHS Not for Resale, 12/17/2007 18:42:26 MSTNo reproduction or networking permitted without license from IHS -,-,- IEC/PAS 61076-2-107 Edi
11、tion 1.0 2007-12 PUBLICLY AVAILABLE SPECIFICATION PRE-STANDARD Connectors for electronic equipment Product requirements Part 2-107: Circular connectors Detail specification for circular hybrid connectors M12 with electrical and fibre-optic contacts with screw-locking INTERNATIONAL ELECTROTECHNICAL C
12、OMMISSION V ICS 31.220.10 PRICE CODE ISBN 2-8318-9501-4 Copyright International Electrotechnical Commission Provided by IHS under license with IECLicensee=IHS Employees/1111111001, User=Japan, IHS Not for Resale, 12/17/2007 18:42:26 MSTNo reproduction or networking permitted without license from IHS
13、 -,-,- 2 PAS 61076-2-107 IEC:2007(E) CONTENTS FOREWORD.4 1 General information7 1.1 Scope7 1.2 Recommended method of termination .7 1.3 Ratings and characteristics .7 1.3.1 Electrical contacts .7 1.3.2 Optic contacts .8 1.4 Normative references 8 1.5 Marking .9 1.6 Safety aspects.9 2 Technical infor
14、mation .9 2.1 Terms and definitions9 2.1.1 Mounting orientation9 2.2 Survey of styles and variants.9 2.2.1 Fixed connectors .9 2.2.2 Free connectors 10 2.2.3 Adaptor .11 3 Dimensions 12 3.1 General.12 3.2 Interface dimensions .12 3.2.1 Pin front view plug connector.12 3.3 Engagement (mating) informa
15、tion13 3.4 Gauges for electric contacts14 4 Characteristics .15 4.1 Climatic category.15 4.2 Electrical characteristics (only electrical contacts).15 4.2.1 Rated voltage Impulse voltage Pollution degree.15 4.2.2 Voltage proof.15 4.2.3 Current-carrying capacity.15 4.2.4 Contact resistance.16 4.2.5 In
16、sulation resistance16 4.3 Optic characteristics (only optic contacts)16 4.4 Mechanical16 4.4.1 IP degree of protection 16 4.4.2 Mechanical operation 16 4.4.3 Insertion and withdrawal forces .16 4.4.4 Contact retention in insert16 4.4.5 Polarizing method17 4.4.6 Vibration (sinusoidal).17 5 Test sched
17、ule.17 5.1 General.17 5.1.1 Arrangement for contact resistance measurements17 5.1.2 Arrangement for dynamic stress tests (vibration) .18 5.2 Test schedule19 5.2.1 Test group P Preliminary 19 5.2.2 Test group AP Dynamic/ Climatic21 Copyright International Electrotechnical Commission Provided by IHS u
18、nder license with IECLicensee=IHS Employees/1111111001, User=Japan, IHS Not for Resale, 12/17/2007 18:42:26 MSTNo reproduction or networking permitted without license from IHS -,-,- PAS 61076-2-107 IEC:2007(E) 3 5.2.3 Test group BP Mechanical endurance.25 5.2.4 Test group CP Electrical load .28 5.2.
19、5 Test group DP Chemical resistivity .29 5.2.6 Test group EP Connection method tests .30 BIBLIOGRAPHY .31 Figure 1 Fixed connector, electrical female contacts, single hole mounting thread M16 1,5 mounting orientation.10 Figure 2 Fixed connector, electrical female contacts, for feed through, single h
20、ole mounting thread M16 1,5 .10 Figure 3 Free connector, straight version, with locking nut, male contacts .11 Figure 4 Adaptor, straight version, without locking nut .11 Figure 5 - Pin front view plug connector12 Figure 6 Engagement (mating) information 13 Figure 7 Gauge dimensions .14 Figure 8 Con
21、tact resistance arrangement.18 Figure 9 Dynamic stress test arrangement A18 Figure 10 Dynamic stress test arrangement B18 Table 1 Styles of fixed connectors .9 Table 2 Styles of free connectors.10 Table 3 Styles of adaptors .11 Table 4 Dimensions connectors Type D in mated position13 Table 5 - Gauge
22、s14 Table 6 Climatic Category15 Table 7 Rated voltage Impulse voltage Pollution degree 15 Table 8 Voltage proof.15 Table 9 Number of mechanical operations .16 Table 10 Insertion and withdrawal forces .16 Table 11 Number of test specimens .17 Table 12 Test group P .19 Table 13 Test group AP .21 Table
23、 14 Test group BP .25 Table 15 Test group CP .28 Table 16 Test group DP .29 Table 17 Test group EP .30 Copyright International Electrotechnical Commission Provided by IHS under license with IECLicensee=IHS Employees/1111111001, User=Japan, IHS Not for Resale, 12/17/2007 18:42:26 MSTNo reproduction o
24、r networking permitted without license from IHS -,-,- 4 PAS 61076-2-107 IEC:2007(E) INTERNATIONAL ELECTROTECHNICAL COMMISSION _ CONNECTORS FOR ELECTRONIC EQUIPMENT PRODUCT REQUIREMENTS Part 2-107: Circular connectors Detail specification for circular hybrid connectors M12 with electrical and fibre-o