《HD-383-S2-A2-1993.pdf》由会员分享,可在线阅读,更多相关《HD-383-S2-A2-1993.pdf(6页珍藏版)》请在三一文库上搜索。
1、- CENELEC Rue d e Stassart. 35 - B 1050 Bruxelles TBI (+ 32 2) 519 68 7 1 - Fax (f 32 2) 519 69 19 Teletex 206 2210097 C E N C E L - T x 172210097 = 3404583 0060942 771 I N F O R M A T I O N SHEET 1 HD 363 S Z I A Z Issue 1 1 9 9 3 - 0 3 - 1 7 1 March 1 9 9 3 Conductors o f insulated cables First su
2、pplement: Guide to the dimensional limits of circular conductors Ames des cibles isols Premier complement: Guide pour les limites dimensionnelles des imes circulaires Leiter fr Kabel und isolierte Lei tungan Erste Ergnzung: Richtlinien fr dio dimentionsmiigen Grenzen von Rundleitsrn RO: IEC 228:19?8
3、 + I E C 228A:1982, modified Related to Directive: - This amendment consists o f the following: - Title Page - Text prepared by CENELEC Technical Connittee TC 20 date of ratification : 1992-12-09 date o f announcement : 1993-06-01 date o f withdrawal : 1993-12-01 date o f latest publication : 1993-1
4、2-01 LIST OF NATIONAL STANDARDS IS GIVEN OVERLEAF - 3404583 00b0943 608 H A R M O N I Z E D N A T I O N A L S T A N D A R D S HO 3 8 3 C Z : 1 9 8 6 I A L : 1 9 9 3 A T : BE : CH : DE : OK : ES : F I : FR : GB : GR : I : IS : I f : LU : NL : NO : P I : SE : NOS No standard SP Standard i n preparatio
5、n NR Standard under revision DOCUMENT DHARMONISATION HARMONISIERUNGSDOKUMENT March 1993 UDC 6 2 1 . 3 1 5 . 2 1 6 2 1 . 3 1 5 . 3 4 2 6 2 1 . 3 1 5 . 5 5 - 0 3 4 . 3 - 0 3 . 3 - 0 3 4 . 7 1 - 1 1 . 1 Descriptors: Insulated cables, flexible cords, conductors, dimensions, requirements, classification,
6、 copper, aluminium conductors ENCLISH VERSION Conductors of inrulrtod C 8 b l . S First supplomont: Guido to tho diiinnrionrl limits o f circular conductors Ames dos ciblos isoles Promier compliment: Guido pour les limitos dimonrionnollor dos amos circuairor Leiter fr Kib01 und isoliorto Lei tungon
7、Erst. Erginzung: Richtlinion fr die dimonrionsmibigen Gronzon von Runloitorn This amendment A2 modifies the Harmonization Document HD 383 S2:1986. It was approved by CENELEC on 1992-12-09. CENELEC members aro bound to comply with tho CEN/CENELEC Inernal Regulations which stipulate the conditions f o
8、 r implementation o f this amendment on a national level. Up-to-date lists and bibliographical references concerning national implementation may be obtained on application to the Central Secrotrriat or to rny CENELEC membor. This amendment exists in three official versions (English, French and Germa
9、n). CENELEC members are the national eectrotechnical corninittees of Austria, Belgium, Dmmrrk, Finland, Franco, 6ermany, Greeco, Iceland, Ireland, Italy, Luxembourg, Nrthorlands, Norway, Portugal, Spain, Swoden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standard
10、ization Comit Europen de Normalisation Electrotechniqur Europaischer Komiteo fr Elektrotechnische Normung Contrrl Socrotrriat: ruo do Strsrrrt 35, 8-1050 8rurtolr 1993 Copyright reserved to CENELEC members Ref. No. HO 383 S2:1986/A2:1993 E A = 3404583 00b0945 480 Page 2 HD 383 52:1986/A2:1993 FOREWO
11、RD This amendment was prepared by CENELEC Technical Committee TC 20, Electric cables. It was submitted to the CENELEC Unique Acceptance Procedure (UAP) in March 1992 and was approved by CENELEC as amendment A2 to HD 383 S2 on 9 December 1992. The following dates were fixed: - latest date of announce
12、ment of the amendment at national level - latest date of publication of a harmonized national standard - latest date of withdrawal of conflicting national standards (doa) 1993-06-01 (dop) 1993-12-01 (don) 1993-12-01 For products which have complied with HD 383 S2:1986 and its amendment A1:1989 befor
13、e 1993-12-01, as shown by the manufacturer or by a certification body, this previous standard may continue to apply for production until 1994-12-01. A H 3404583 0060946 317 Introduct ion Clause 4.1.1 Clause 4.2.1 misQ Table I Table II Page j HD 383 S2:i986/A2:1993 Replace the eighth paragraph by the
14、 following text: The same resistance values are specified for plain aluminium conductors and for aluminium alloy conductors. To achieve this standardisation of resistance, there may be a variation in wire sizes used for the same nominal cross-sectional areas according to the particular material used
15、. Replace the text by the following: The conductors may consist of: - plain or metal-coated annealed copper - or plain aluminium or aluminium alloy as specified for the different types of conductor in Clause 4. The term metal-coated means coated with a thin layer of suitable metal, such as tin, tin
16、alloy or lead alloy. Replace the text by the following: Conductors shall consist of: - plain or metal-coated annealed copper; - or plain aluminium or aluminium alloy. Replace the first paragraph by the following: Conductors shall consist of: - plain or metal-coated annealed copper; - or plain alumin
17、ium or aluminium alloy. The second paragraph remains without change. On top of page 17 delete the following text: Plain or metal-coated or metai-clad or metal-coated metal-clad. Replace the heading of column four by: Aluminium conductors, circular or shaped Replace the heading of column 10 by: Aluminium conductor m 3404583 00b0947 253 m - . - - Table V Extend the table with the following values: 31 0.958 32 0.954 33 0.951 34 O. 947 35 0.943
链接地址:https://www.31doc.com/p-3768833.html