1、NORME INTERNATIONALE INTERNATIONAL STANDARD CE1 IEC 61 184 1997 AMENDEMENT 2 AMENDMENT 2 2004-1 O Amendement 2 Douilles a baonnette Amendment 2 Bayonet lampholders O IEC 2004 Droits de reproduction rservs - Copyright - all rights reserved Intemational Electrotechnical Commission, 3, rue de VarembB,
2、PO Box 131, CH-I21 1 Geneva 20, Switzerland Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 O0 E-mail: inmailiec.ch Web: www.iec.ch E CODE PRIX Commission Electrotechnique Internationale PRICE CODE International Electrotechnical Commission MeXflyHapOflHa 3neKTpOTeXHLleCKa KOMMCCM Pourprix, voir c
3、atalogue en vigueur For price, see current catalogue Copyright International Electrotechnical Commission Provided by IHS under license with IECLicensee=NASA Marshall Space Flight Center/9972545001 Not for Resale, 03/07/2007 01:41:21 MSTNo reproduction or networking permitted without license from IHS
4、 -,-,- - 2 - AVANT-PROPOS FDIS Le prsent amendement a t .Ji par le sous-comit 3, dtudes 34 de la CEI: Lampes et quipements associs. Rapport de vote 61 184 amend.2 O CEI:2004 B: Culots et douillles, du comit Le rapport de vote indiqu dans le tableau ci-dessus donne toute information sur le vote ayant
5、 abouti lapprobation de cet amendement. Le comit a dcid que le contenu de cette publication ne sera pas modifi avant la date de maintenance indique sur le site web de la CE1 sous http:/webstore.iec.ch dans les donnes relatives la publication recherche. A cette date, la publication sera reconduite; s
6、upprime; amende. remplace par une dition rvise, ou Page 6 1 Gnralits 1 .I Domaine dapplication Remplacer la dernire phrase du troisime alina par ce qui suit: Les douilles destines tre utilises par les fabricants de luminaires exclusivement ne sont pas destines la vente au dtail. Page 8 1.2 Rfrences
7、normatives Remplacer la rfrence la CE/ 60664 par la nouvelle rfrence suivante: CE1 60664-1, Coordination de lisolement des matriels dans les systmes (rseaux) basse tension - Partie 1: Principes, prescriptions et essais Remplacer, la page 11, la rfrence la CE/ 60695-2-1/1 par la nouvelle rfrence suiv
8、ante: CE1 60695-2-11, Essais relatifs aux risques du feu - Partie 2-11: Essais au fil incandescent/chauffant - Mthode dessai dinflammabilit pour produits finis Copyright International Electrotechnical Commission Provided by IHS under license with IECLicensee=NASA Marshall Space Flight Center/9972545
9、001 Not for Resale, 03/07/2007 01:41:21 MSTNo reproduction or networking permitted without license from IHS -,-,- 61 184 amend.2 O IEC:2004 - 3 - FDIS FOREWORD Report on voting This amendment has been prepared by subcommittee 34B: Lamp caps and holders, of IEC technical committee 34: Lamps and relat
10、ed equipment. Full information on the voting for the approval of this amendment can be found in the report on voting indicated in the above table. The committee has decided that the contents of this publication will remain unchanged until the maintenance result date indicated on the I EC web site un
11、der “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publication will be reconfirmed; withdrawn; amended. replaced by a revised edition, or Page 7 1 General 1.1 Scope Replace the last sentence of the third paragraph by the following: Lampholders for use by l
12、uminaire manufacturers only are not for retail sale. Page 9 1.2 Normative references Replace the reference to IEC 60664 with the following new reference: IEC 60664-1, Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests Replace, on page 11, th
13、e reference to IEC 60695-2-1/1 with the following new reference: IEC 60695-2-1 1, Fire hazard testing - Part 2-1 1: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products Copyright International Electrotechnical Commission Provided by IHS under license with IECLice
14、nsee=NASA Marshall Space Flight Center/9972545001 Not for Resale, 03/07/2007 01:41:21 MSTNo reproduction or networking permitted without license from IHS -,-,- - 4 - 61 184 amend.2 O CEI:2004 Page 10 2 Dfinitions Ajouter la fin de cet article, en page 14, les nouvelles dfinitions suivantes: 2.22 cat
15、gorie de tenue aux chocs chiffre dfinissant une condition de surtension transitoire NOTE Les catgories de tenue aux chocs I, II, III et IV sont utilises. a) But de la classification des catgories de tenue aux chocs. Les catgories de tenue aux chocs servent diffrencier les diffrents degrs de validit
16、des quipements compte tenu des attentes requises en matire de continuit de service et de tolrance des risques de dfauts. En slectionnant les niveaux de tenue aux chocs des quipements, on peut raliser la coordination de lisolement peut tre ralise pour linstallation complte en rduisant le risque de df
17、aut un niveau acceptable qui servira de base dans la matrise de la surtension. Un chiffre plus lev dsignant la catgorie de tenue aux chocs indique une tenue aux chocs de lquipement plus leve et permet un plus grand choix de mthodes pour la matrise de la surtension. Le concept de catgorie de tenue au
18、x chocs est utilis pour les quipements directement aliments par le rseau. b) Description des catgories de tenue aux chocs. Un quipement de catgorie de tenue aux chocs I est un quipement destin a tre connect linstallation fixe des btiments. Des moyens de protection sont pris lextrieur de lquipement -
19、 soit dans linstallation fixe, soit entre linstallation fixe et lquipement - pour limiter les surtensions transitoires un niveau donn. Un quipement de catgorie de tenue aux chocs II est un quipement destin a tre connect linstallation fixe des btiments. Un quipement de catgorie de tenue aux chocs III
20、 est un quipement qui constitue une partie de linstallation fixe et des autres quipements dont le degr de validit attendu est plus lev. Un quipement de catgorie de tenue aux chocs IV est destin tre utilis proximit ou dans les installations lectriques des btiments en amont du tableau de distribution.
21、 2.23 circuit primaire circuit directement connect au rseau alternatif. II comporte, par exemple, les moyens de connexion au rseau alternatif, les enroulements primaires des transformateurs, moteurs et autres dispositifs en charge 2.24 circuit secondaire circuit qui na pas de connexion directe avec
22、le circuit primaire en tirant sa puissance dun transformateur, dun convertisseur ou dun systme disolation quivalent, ou dun accumulateur Exception: les autotransformateurs. Bien quayant une connexion directe avec le circuit primaire, leur partie connecte est galement considre comme un circuit second
23、aire au sens de la prsente dfinition NOTE - Les rgimes transitoires dans de tels circuits sont amortis par lenroulement primaire correspondant. Les ballasts inductifs rduisent galement la valeur de la tension des rgimes transitoires. En consquence, les composants situs aprs un circuit primaire ou ap
24、rs un ballast inductif peuvent tre adapts une catgorie de tenue aux chocs un niveau plus bas, cest-dire une catgorie de tenue aux chocs II. Copyright International Electrotechnical Commission Provided by IHS under license with IECLicensee=NASA Marshall Space Flight Center/9972545001 Not for Resale,