1、 NORME INTERNATIONALE CEI IEC INTERNATIONAL STANDARD 61076-2-101 2003 AMENDEMENT 1 AMENDMENT 1 2006-02 Amendement 1 Connecteurs pour quipements lectroniques Partie 2-101: Connecteurs circulaires Spcification particulire pour les connecteurs circulaires M8 vis ou encliquetage, M12 vis pour applicatio
2、ns basse tension Amendment 1 Connectors for electronic equipment Part 2-101: Circular connectors Detail specification for circular connectors M8 with screw- or snap-locking, M12 with screw-locking for low voltage applications Pour prix, voir catalogue en vigueur For price, see current catalogue IEC
3、2006 Droits de reproduction rservs Copyright - all rights reserved International Electrotechnical Commission, 3, rue de Varemb, PO Box 131, CH-1211 Geneva 20, Switzerland Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmailiec.ch Web: www.iec.ch Commission Electrotechnique Internatio
4、nale International Electrotechnical Commission H CODE PRIX PRICE CODE 2 61076-2-101 Amend.1 CEI:2006 AVANT-PROPOS Cet amendement a t tabli par le sous-comit 48B: Connecteurs, du comit dtudes 48 de la CEI: Composants lectromcaniques et structures mcaniques pour quipements lectroniques. Le texte de ce
5、t amendement est issu des documents suivants: FDIS Rapport de vote 48B/1591/FDIS 48B/1618/RVD Le rapport de vote indiqu dans le tableau ci-dessus donnent toute information sur le vote ayant abouti lapprobation de cet amendement. Le comit a dcid que le contenu de cet amendement et de la publication d
6、e base ne sera pas modifi avant la date de maintenance indique sur le site web de la CEI sous “http:/webstore.iec.ch“ dans les donnes relatives la publication recherche. A cette date, la publication sera reconduite, supprime, remplace par une dition rvise, ou amende. _ Page 2 SOMMAIRE Ajouter le tit
7、re de lAnnexe B suivant: Annexe B Diamtre extrieur du corps du connecteur femelle Page 14 1.1 Domaine dapplication Ajouter le nouveau texte suivant, la fin de ce paragraphe: Elle sapplique galement aux connecteurs circulaires M12 4 ples codages intgrs (cest-dire codage-D) pour utilisation dans les e
8、nvironnements industriels des frquences de 100 MHz et au-del comme pour lEthernet industriel (voir Note 1), aux connecteurs circulaires M12 5 ples codage intgr (codage-B) pour utilisation dans les environnements industriels dans les bus de terrain comme le Profibus DP et lInterbus et aux connecteurs
9、 circulaires M12 5 ples codage intgr (codage-P) pour utilisation dans les applications basse tension comme interface 4 + PE avec un contact central ddi au PE comme contact squentiel (voir Note 2). 61076-2-101 Amend. 1 IEC:2006 3 FOREWORD This amendment has been prepared by subcommittee 48B: Connecto
10、rs, of IEC Technical Committee 48: Electromechanical components and mechanical structures for electronic equipment. The text of this amendment is based on the following documents FDIS Report on voting 48B/1591/FDIS 48B/1618/RVD Full information on the voting for the approval of this amendment can be
11、 found in the report on voting indicated in the above table. The committee has decided that the contents of this amendment and the base publication will remain unchanged until the maintenance result date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific
12、publication. At this date, the publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended. _ Page 3 CONTENTS Add the title of Annex B as follows: Annex B Diameter of the female connector body Page 15 1.1 Scope Add at the end of this Subclause, the following new text: It al
13、so applies to 4 pole M12 circular connectors with integrated codings (i.e. D-coding) for use in industrial environments at frequencies of 100 MHz and beyond like Industrial Ethernet (see Note 1), to 5 pole M12 circular connectors with an integrated coding (B-coding) for use in industrial environment
14、s in fieldbuses like Profibus DP and Interbus, and to a 5-pole M12 circular connectors with an integrated coding (P-coding) for use in low voltage applications as a 4 + PE interface, with a centre contact dedicated to PE as a first make last break contact (see Note 2). 4 61076-2-101 Amend.1 CEI:2006
15、 Les codages B, D et P empchent laccouplement de ces connecteurs cods mles ou femelles avec toute autre interface ainsi que laccouplement crois entre dispositifs codage B, D et P. NOTE 1 Les codages D pour dautres applications / gammes de frquences sont ltude. NOTE 2 Les valeurs nominales et les car
16、actristiques pour les versions 4 + PE (codage-P) et Profibus DP/ Interbus (codage-B) sont les mmes que pour la version 5 ples. Page 18 1.6 Dsignation de type CEI Ajouter une nouvelle lettre lextrmit droite de la dsignation de type: Lettre indiquant les dispositifs de codage Standard selon 61076-2-10
17、1:2003 (Ed 1) A Comme Profibus DP/Interbus . B A dterminer (prochaine dition) .C Comme Ethernet industrielD M12 avec contact de terre de protection (PE) P Page 20 1.7 Rfrences pour les commandes Remplacer les deux exemples par ce qui suit: EXEMPLE 1 fiche non dmontable. DMF 004 G1B 020 3A D Fiche M1
18、2 Modle MF, non dmontable, version sortie coude avec contacts femelles, 4 ples, anneau molet, finition des contacts en or, niveau de contrle B, longueur de cble 2,0 m, section de fil 0,34 mm, gaine de cble en PUR, codage D. EXEMPLE 2 fiche dmontable. DKM 004 GC3B D Fiche M12 Modle KM, dmontable, ver
19、sion sortie coude avec contacts femelles, 4 ples, anneau molet, sorties sertir, finition des contacts en tain, niveau de contrle B, codage D. -,-,- 61076-2-101 Amend. 1 IEC:2006 5 The B, D and P-codings prevent the mating of these coded male or female connectors to any other interfaces and cross mat
20、ing between B, D, and P-coding. NOTE 1 D-codings for other applications/frequency ranges are under consideration. NOTE 2 Ratings and characteristics for the 4+PE versions (P-coding) and Profibus DP/ Interbus (B-coding) are the same as for 5 pole version. Page 19 1.6 IEC Type designation Add, at the
21、right-hand side of the type designation, a new letter: Letter denoting coding devices Standard per 61076-2-101:2003 (Ed 1) A Like Profibus DP/Interbus B To be determined (next edition) C Like Industrial Ethernet.D M12 with protective earth contact (PE) P Page 21 1.7 Ordering information Replace the
22、two existing examples by the following: EXAMPLE 1 non-rewireable free connector. DMF 004 G1B 020 3A D Free connector M12 Style MF, non-rewireable, right angled version with female contacts, 4 poles, with knurled ring, gold contact finish, assessment level B, cable length 2,0 m, cross section of wire
23、 0,34 mm, PUR cable jacket, D-coding. EXAMPLE 2 rewireable free connector. DKM 004 GC3B D Free connector M12 Style KM, rewireable, right angled version with female contacts, with 4 poles, with knurled ring, crimp terminals, tin contact finish, assessment level B, D-coding. 6 61076-2-101 Amend.1 CEI: