IEC-TR-61955-1998.pdf
《IEC-TR-61955-1998.pdf》由会员分享,可在线阅读,更多相关《IEC-TR-61955-1998.pdf(18页珍藏版)》请在三一文库上搜索。
1、TECHNICAL REPORT IEC 61955 First edition 1998-08 Primary batteries Summary of research and actions limiting risks to reversed installation of primary batteries Piles Rsum des recherches et des mesures de limitation des risques dus linstallation de piles avec polarit inverse Reference number IEC 6195
2、5:1998(E) Numbering As from 1 January 1997 all IEC publications are issued with a designation in the 60000 series. Consolidated publications Consolidated versions of some IEC publications including amendments are available. For example, edition numbers 1.0, 1.1 and 1.2 refer, respectively, to the ba
3、se publication, the base publication incorporating amendment 1 and the base publication incorporating amendments 1 and 2. Validity of this publication The technical content of IEC publications is kept under constant review by the IEC, thus ensuring that the content reflects current technology. Infor
4、mation relating to the date of the reconfirmation of the publication is available in the IEC catalogue. Information on the subjects under consideration and work in progress undertaken by the technical committee which has prepared this publication, as well as the list of publications issued, is to be
5、 found at the following IEC sources: IEC web site* Catalogue of IEC publications Published yearly with regular updates (On-line catalogue)* IEC Bulletin Available both at the IEC web site* and as a printed periodical Terminology, graphical and letter symbols For general terminology, readers are refe
6、rred to IEC 60050: International Electrotechnical Vocabulary (IEV). For graphical symbols, and letter symbols and signs approved by the IEC for general use, readers are referred to publications IEC 60027: Letter symbols to be used in electrical technology, IEC 60417: Graphical symbols for use on equ
7、ipment. Index, survey and compilation of the single sheets and IEC 60617: Graphical symbols for diagrams. * See web site address on title page. -,-,- TECHNICAL REPORT TYPE 3 IEC 61955 First edition 1998-08 Primary batteries Summary of research and actions limiting risks to reversed installation of p
8、rimary batteries Piles Rsum des recherches et des mesures de limitation des risques dus linstallation de piles avec polarit inverse Commission Electrotechnique Internationale International Electrotechnical Commission PRICE CODE IEC 1998 Copyright - all rights reserved No part of this publication may
9、 be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. International Electrotechnical Commission3, rue de Varemb Geneva, Switzerland Telefax: +41 22 919 0300e-mail: inmailiec.ch IEC web
10、 site http: /www.iec.ch F For price, see current catalogue 2 61955 IEC:1998 (E) CONTENTS Page FOREWORD .3 Clause 1 Scope .4 2 Reference documents .4 3 Background.4 4 General.5 4.1 Battery compartment guidelines .5 4.2 Clarification note to IEC 60086-15 4.3 Consumer information5 4.4 Concentricity of
11、the positive terminal 5 4.5 IEC 60086-5 Product safety standard for primary batteries.5 5 Conclusion6 Annex A (informative)Consumer information leaflet.7 Annex B (informative)Battery compartment guidelines.9 -,-,- 61955 IEC:1998 (E) 3 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ PRIMARY BATTERIES Sum
12、mary of research and actions limiting risks to reversed installation of primary batteries FOREWORD 1)The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of the IE
13、C is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, the IEC publishes International Standards. Their preparation is entrusted to technical committees; any IEC National Committ
14、ee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization for Standardization (ISO) in a
15、ccordance with conditions determined by agreement between the two organizations. 2)The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from
16、all interested National Committees. 3)The documents produced have the form of recommendations for international use and are published in the form of standards, technical reports or guides and they are accepted by the National Committees in that sense. 4)In order to promote international unification,
17、 IEC National Committees undertake to apply IEC International Standards transparently to the maximum extent possible in their national and regional standards. Any divergence between the IEC Standard and the corresponding national or regional standard shall be clearly indicated in the latter. 5)The I
18、EC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with one of its standards. 6)Attention is drawn to the possibility that some of the elements of this International Standard may be the subject of patent rights.
19、 The IEC shall not be held responsible for identifying any or all such patent rights. The main task of IEC technical committees is to prepare International Standards. In exceptional circumstances, a technical committee may propose the publication of a technical report of one of the following types:
20、type 1, when the required support cannot be obtained for the publication of an International Standard, despite repeated efforts; type 2, when the subject is still under technical development or where for any other reason there is the future but no immediate possibility of an agreement on an Internat
21、ional Standard; type 3, when a technical committee has collected data of a different kind from that which is normally published as an International Standard, for example “state of the art“. Technical reports of types 1 and 2 are subject to review within three years of publication to decide whether t
22、hey can be transformed into International Standards. Technical reports of type 3 do not necessarily have to be reviewed until the data they provide are considered to be no longer valid or useful. IEC 61955, which is a technical report of type 3, has been prepared by technical committee 35: Primary c
23、ells and batteries. The text of this technical report is based on the following documents: Committee draftReport on voting 35/1030/CDV35/1045/RVC Full information on the voting for the approval of this technical report can be found in the report on voting indicated in the above table. A bilingual ve
24、rsion of this report may be issued at a later date. -,-,- 4 61955 IEC:1998 (E) PRIMARY BATTERIES Summary of research and actions limiting risks to reversed installation of primary batteries 1 Scope This technical report provides information relevant to the safe design of batteries and battery powere