BS-6226-1982 EN-50032-1980.pdf
《BS-6226-1982 EN-50032-1980.pdf》由会员分享,可在线阅读,更多相关《BS-6226-1982 EN-50032-1980.pdf(14页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS 6226:1982 EN 50032: 1980 Specification for Low voltage switchgear and controlgear for industrial use Inductive proximity switches Definitions, classification and designation This European Standard EN 50032 was given as from 30 July 1982 the status of a British Standard UDC 621.31
2、6.542.9:621.3.011.3:621.3.027.2:001.4 Licensed Copy: sheffieldun sheffieldun, na, Tue Dec 05 07:19:03 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 6226:1982 This British Standard was published under the authority of the Board of BSI and comes into effect on 30 July 1982 BSI 10-1999 The following BS
3、I references relate to the work on this standard: Committee reference PEL/10 Draft for comment 78/23247 DC ISBN 0 580 12776 1 Cooperating organizations The European Committee for Electrotechnical Standardization (CENELEC), under whose supervision this European Standard was prepared, comprises the Na
4、tional Committees of the following countries. AustriaLuxemburg BelgiumNetherlands DenmarkNorway FinlandPortugal FranceSpain GermanySweden GreeceSwitzerland IrelandUnited Kingdom Italy Amendments issued since publication Amd. No.Date of issueComments Licensed Copy: sheffieldun sheffieldun, na, Tue De
5、c 05 07:19:03 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 6226:1982 BSI 10-1999i Contents Page Cooperating organizationsInside front cover Text of EN 500323 National appendix A8 National appendix B8 Publications referred toInside back cover Licensed Copy: sheffieldun sheffieldun, na, Tue Dec 05 07
6、:19:03 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 6226:1982 ii BSI 10-1999 A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself con
7、fer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, the EN title page, pages 2 to 8, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. Th
8、is will be indicated in the amendment table on the inside front cover. Licensed Copy: sheffieldun sheffieldun, na, Tue Dec 05 07:19:03 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 50032 Edition 1 October 1980 UDC 621.316.542.9:621.3.011.3:621.3.027.
9、2:001.4 Key words: Electrical switchgear and controlgear, industrial use, low voltage, proximity switches, inductive proximity switches, operating distance, operating frequency English version Low voltage switchgear and controlgear for industrial use Inductive proximity switches Definitions, classif
10、ication and designation Appareillage industriel basse tension Dtecteurs de proximit inductifs Dfinitions, classification et dsignation Industrielle Niederspannungs-Schaltgerte Induktive Nherungsschalter Begriffe, Einteilung, Bezeichnung This European Standard was accepted by CENELEC on 1980-10-02. T
11、he CENELEC members are bound to adhere to the CENELEC Internal Regulations which specify under which conditions this European Standard has to be given, without any alteration, the status of a national standard. Up-to-date lists and bibliographical references concerning such national standards may be
12、 obtained on application to the CENELEC General Secretariat or to any CENELEC member. This European Standard is established by CENELEC in three official versions (English, French, German). A translation made by another member under its own responsibility, in its own language, and notified to CENELEC
13、 has the same status. CENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Ireland, Italy, Luxemburg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical
14、Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels Copyright reserved to all CENELEC members Licensed Copy: sheffieldun sheffieldun, na, Tue Dec 05 07:19:03 GMT+00:00 2006, Uncontro
15、lled Copy, (c) BSI EN 50032:1980 BSI 10-1999 2 Contents Page 1Scope3 2General definitions3 3Definitions of geometrical characteristics3 4Definitions of electrical characteristics4 5Classification5 Annex Diagrammatic representation of operating distances7 Table 1 Designation code6 Licensed Copy: shef
16、fieldun sheffieldun, na, Tue Dec 05 07:19:03 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 50032:1980 BSI 10-19993 This European Standard has been prepared by the CENELEC Technical Committee 17X. 1 Scope This standard defines terms related to contactless inductive proximity switches, with one sensin
17、g face, and specifies the classification and designation to be used for such switches. 2 General definitions 2.1 inductive proximity switch an inductive proximity switch is a device producing a high frequency electromagnetic field in a sensing zone and having an electric contactless output the outpu
18、t signal is determined by the pressure or the absence in the electromagnetic field of a metallic object of sufficient size 2.2 sensing face the sensing face is a flat surface of the proximity switch through which the high frequency electromagnetic field emerges NOTEThe sensing face is marked by the
19、manufacturer. 2.3 reference axis a reference axis is an axis perpendicular to the sensing face and passing through its centre 2.4 target a target is an object used for making comparative measurements of the operating distance, its characteristics are specified in the standard EN 50010 the target pla
20、ne shall be maintained parallel to the sensing face of the proximity switch 2.5 free zone The free zone is a volume around the proximity switch which shall be kept free from any material capable of affecting the characteristics of the proximity switch. 2.5.1 non-damping material a non-damping materi
21、al is a material which has a negligible influence on characteristics of a proximity switch 2.5.2 embedded in metal proximity switch a proximity switch is “embedded in metal” when any metallic piece can be put around, below and up to the sensing face plane, without influencing its characteristics 2.5
22、.3 not embedded in metal proximity switch a proximity switch is “not embedded in metal” if it is necessary to have a free zone around the sensing face in order to maintain its characteristics 3 Definitions of geometrical characteristics 3.1 operating distance s (see Annex) The operating distance is
23、the distance at which the target approaching the sensing face causes the output signal to change. Licensed Copy: sheffieldun sheffieldun, na, Tue Dec 05 07:19:03 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 50032:1980 4 BSI 10-1999 3.1.1 rated operating distance sn the rated operating distance is a
24、 conventional quantity used to designate the operating distance. It does not take into account either manufacturing tolerances or variations due to external conditions such as voltage and temperature 3.1.2 effective operating distance sr the effective operating distance is the operating distance of