IEC-62056-42-2002.pdf
《IEC-62056-42-2002.pdf》由会员分享,可在线阅读,更多相关《IEC-62056-42-2002.pdf(34页珍藏版)》请在三一文库上搜索。
1、INTERNATIONAL STANDARD IEC 62056-42 First edition 2002-02 Electricity metering Data exchange for meter reading, tariff and load control Part 42: Physical layer services and procedures for connection-oriented asynchronous data exchange Reference number IEC 62056-42:2002(E) Publication numbering As fr
2、om 1 January 1997 all IEC publications are issued with a designation in the 60000 series. For example, IEC 34-1 is now referred to as IEC 60034-1. Consolidated editions The IEC is now publishing consolidated versions of its publications. For example, edition numbers 1.0, 1.1 and 1.2 refer, respectiv
3、ely, to the base publication, the base publication incorporating amendment 1 and the base publication incorporating amendments 1 and 2. Further information on IEC publications The technical content of IEC publications is kept under constant review by the IEC, thus ensuring that the content reflects
4、current technology. Information relating to this publication, including its validity, is available in the IEC Catalogue of publications (see below) in addition to new editions, amendments and corrigenda. Information on the subjects under consideration and work in progress undertaken by the technical
5、 committee which has prepared this publication, as well as the list of publications issued, is also available from the following: IEC Web Site (www.iec.ch) Catalogue of IEC publications The on-line catalogue on the IEC web site (www.iec.ch/catlg-e.htm) enables you to search by a variety of criteria
6、including text searches, technical committees and date of publication. On-line information is also available on recently issued publications, withdrawn and replaced publications, as well as corrigenda. IEC Just Published This summary of recently issued publications (www.iec.ch/JP.htm) is also availa
7、ble by email. Please contact the Customer Service Centre (see below) for further information. Customer Service Centre If you have any questions regarding this publication or need further assistance, please contact the Customer Service Centre: Email: custserviec.ch Tel: +41 22 919 02 11 Fax: +41 22 9
8、19 03 00 INTERNATIONAL STANDARD IEC 62056-42 First edition 2002-02 Electricity metering Data exchange for meter reading, tariff and load control Part 42: Physical layer services and procedures for connection-oriented asynchronous data exchange PRICE CODE IEC 2002 Copyright - all rights reserved No p
9、art of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. International Electrotechnical Commission3, rue de Varemb Geneva, Switzerland Telefax: +41 22 919 0300e
10、-mail: inmailiec.ch IEC web site http:/www.iec.ch N For price, see current catalogue Commission Electrotechnique Internationale International Electrotechnical Commission 2 62056-42 IEC:2002(E) CONTENTS FOREWORD 4 1Scope.5 2Normative references .5 3Terms, definitions and abbreviations 6 4Overview 7 5
11、Service specification.8 5.1List of services 8 5.1.1Connection establishment/release related services8 5.1.2Data communication services 8 5.1.3Layer management services 8 5.2Use of the physical layer services .9 5.3Service definitions.9 5.3.1PH-CONNECT.request 9 5.3.2PH-CONNECT.indication .10 5.3.3PH
12、-CONNECT.confirm 10 5.3.4PH-ABORT.request .11 5.3.5PH-ABORT.confirm .11 5.3.6PH-ABORT.indication 11 5.3.7PH-DATA.request12 5.3.8PH-DATA.indication.12 6Protocol specification .13 6.1Physical layer protocol data unit13 6.2Transmission order and characteristics .13 6.3Physical layer operation descripti
13、on of the procedures .13 6.3.1General .13 6.3.2Setting up a physical connection .14 6.3.3The identification service.15 6.3.4Data communications 19 6.3.5Disconnection of an existing physical connection.19 Annex A (informative) An example: PH service primitives and Hayes commands 20 Annex B (informati
14、ve) Data model and protocol 25 Bibliography26 Figure 1 Typical PSTN configuration7 Figure 2 The location of the physical layer .8 Figure 3 Protocol layer services of the COSEM 3-layer connection oriented profile9 Figure 4 MSC for physical connection establishment15 Figure 5 MSC for IDENTIFY.request/
15、.response message exchange .17 Figure 6 Handling the identification service at the COSEM server side.17 Figure 7 Partial state machine for the client side physical layer18 Figure A.1 MSC for physical connection request 20 Figure A.2 Physical connection establishment at the CALLING station.21 Figure
16、A.3 MSC for physical connection establishment 22 Figure A.4 Data exchange between the calling and called stations.23 Figure A.5 MSC for a physical disconnection .24 Figure B.1 The three-step approach of COSEM .25 62056-42 IEC:2002(E) 3 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ ELECTRICITY METERING
17、 DATA EXCHANGE FOR METER READING, TARIFF AND LOAD CONTROL Part 42: Physical layer services and procedures for connection-oriented asynchronous data exchange FOREWORD 1)The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising all national electrot
18、echnical committees (IEC National Committees). The object of the IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, the IEC publishes International Standards. Their prepara
19、tion is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. The IEC collaborates closely
20、 with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2)The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an international consensus of opinion on the releva
21、nt subjects since each technical committee has representation from all interested National Committees. 3)The documents produced have the form of recommendations for international use and are published in the form of standards, technical specifications, technical reports or guides and they are accept
22、ed by the National Committees in that sense. 4) In order to promote international unification, IEC National Committees undertake to apply IEC International Standards transparently to the maximum extent possible in their national and regional standards. Any divergence between the IEC Standard and the
23、 corresponding national or regional standard shall be clearly indicated in the latter. 5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with one of its standards. The International Electrotechnical Com
24、mission (IEC) draws attention to the fact that it is claimed that compliance with this International Standard may involve the use of a maintenance service concerning the stack of protocols on which the present standard IEC 62056-42 is based. The IEC takes no position concerning the evidence, validit