BS-5452-1977.pdf
《BS-5452-1977.pdf》由会员分享,可在线阅读,更多相关《BS-5452-1977.pdf(16页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS 5452:1977 Specification for Hospital hollow-ware made of plastics material UDC 615.478.77:678.5 Licensed Copy: sheffieldun sheffieldun, na, Fri Dec 01 13:49:16 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 5452:1977 This British Standard, having been prepared under the direction
2、of the Surgical Instruments and Medical Appliances Standards Committee, was published under the authority of the Executive Board on 28 February 1977 BSI 11-1999 The following BSI references relate to the work on this standard: Committee reference SGS/7 Draft for comment 75/62412DC ISBN 0 580 09571 1
3、 Cooperating organizations The Surgical Instruments and Medical Appliances Standards Committee, under whose supervision this British Standard was prepared, consists of representatives from the following Government departments and professional and industrial organizations: Association of Anaesthetist
4、s of Great Britain and Northern Ireland Association of British Sterilizer Manufacturers British Dental Association British Institute of Surgical Technicians* British Medical Association British Paediatric Association British Rubber Manufacturers Association Limited British Surgical Trades Associatio
5、n (Inc.)* Department of Health and Social Security* Disposable Hypodermic and Allied Equipment Manufacturers Association Medical Defence Union Medical Protection Society Medical Sterile Products Association Ministry of Agriculture, Fisheries and Food Ministry of Defence* Queens Institute of District
6、 Nursing* Royal College of Midwives* Royal College of Obstetricians and Gynaecologists* Royal College of Surgeons of Edinburgh* Royal College of Veterinary Surgeons Royal Institute of Public Health and Hygiene Scientific Instrument Manufacturers Association of Great Britain The organizations marked
7、with an asterisk in the above list, together with the following, were directly represented on the committee entrusted with the preparation of this British Standard: Association of Sterile Supply Administrators British Aluminium Holloware Manufacturers Association British Paper Box Association Britis
8、h Plastics Federation Institute of Purchasing and Supply Royal College of Nursing and National Council of Nurses of the UK Royal College of Physicians of London Stainless Steel Fabricators Association Amendments issued since publication Amd. No.Date of issueComments Licensed Copy: sheffieldun sheffi
9、eldun, na, Fri Dec 01 13:49:16 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 5452:1977 BSI 11-1999i Contents Page Cooperating organizationsInside front cover Forewordii 1Scope1 2References1 3Dimensions1 4Materials1 5Design1 6Freedom from toxicity2 7Finish and workmanship2 8Covers2 9Impact resistance
10、2 10Effect of sterilization2 11Resistance to handling under load2 12Marking2 Appendix A Method of test for sterilization4 Appendix B Method of test under load4 Figure 1 Rectangular instrument tray5 Figure 2 Typical compartmented instrument tray6 Figure 3 Kidney dish7 Figure 4 Typical wash bowl8 Figu
11、re 5 Lotion bowls8 Figure 6 Gallipots9 Figure 7 Jugs9 Figure 8 The “envelope” fold10 Table 1 Dimensions of plastics hollow-ware3 Publications referred toInside back cover Licensed Copy: sheffieldun sheffieldun, na, Fri Dec 01 13:49:16 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 5452:1977 ii BSI 11
12、-1999 Foreword This British Standard was prepared at the request of the British Plastics Federation and authorized by the Surgical Instrument and Medical Appliances Standards Committee of BSI. The standard has been prepared to establish acceptance standards for plastics hollow-ware for use in hospit
13、als and other health service areas. Requirements for quality and finish are laid down to ensure that articles give a satisfactory performance for their stated use within the range of this specification. BS 1823 deals with stainless steel hollow-ware for use in hospital operating theatres and wards.
14、At elevated temperatures, plastics material may suffer deformation under stress and care should be taken in the packaging of the articles and in the loading of them into the sterilization chamber. When flammable anaesthetics are used, hollow-ware from plastics materials capable of generating and ret
15、aining electrostatic surface charges should not be brought within 0.25 m of any part of an anaesthetic breathing circuit. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance wi
16、th a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 10, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had a
17、mendments incorporated. This will be indicated in the amendment table on the inside front cover. Licensed Copy: sheffieldun sheffieldun, na, Fri Dec 01 13:49:16 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 5452:1977 BSI 11-19991 1 Scope This British Standard specifies requirements for hospital holl
18、ow-ware made of plastics materials. Provision is made for the following nominal sizes: 2 References The titles of the publications referred to in this standard are listed on the inside back cover. 3 Dimensions The dimensions of each plastics utensil (excluding jugs) shall be as given in Table 1. 4 M
19、aterials The hollow-ware shall be made from suitable plastics material, which shall comply with the requirements of clauses 10 and 11. 5 Design 5.1 General 5.1.1 The design shall be such as to prevent utensils from jamming together if stacked. 5.1.2 The base shall be designed to prevent suction on f
20、lat surfaces and to allow for drainage in the inverted position. 5.2 Rectangular instrument trays 5.2.1 Size designation. The size of rectangular instrument trays shall be designated by the nominal internal length and nominal internal width as shown in Table 1 and Figure 1. 5.2.2 Size range. The ran
21、ge of sizes shall be as given in Table 1. 5.2.3 Design. The design and dimensions of rectangular instrument trays shall be in accordance with Figure 1 and Table 1. 5.3 Compartmented instrument tray 5.3.1 Size. The size of the compartmented instrument tray shall be designated by the nominal overall d
22、imensions as shown in Table 1 and Figure 2. 5.3.2 Design. The design and dimensions of the compartmented instrument tray shall generally be in accordance with Figure 2. The tray shall have four compartments. 5.4 Kidney dishes 5.4.1 Size designation. The size of kidney dishes shall be designated by t
23、he nominal length between the rim centres as shown in Table 1 and Figure 3. 5.4.2 Size range. The range of sizes of kidney dishes shall be as given in Table 1. 5.4.3 Design. The design and dimensions of kidney dishes shall be in accordance with Figure 3 and Table 1. 5.5 Wash bowl 5.5.1 Size. The siz
24、e of the wash bowl shall be as given in Table 1 and illustrated in Figure 4. 5.5.2 Design. The design and dimensions of the wash bowl shall be in accordance with Figure 4 and Table 1. 5.6 Lotion bowls 5.6.1 Size designation. The size of lotion bowls shall be designated by the nominal internal diamet
- 配套讲稿: