BS-6272-1982 EN-50042-1980.pdf
《BS-6272-1982 EN-50042-1980.pdf》由会员分享,可在线阅读,更多相关《BS-6272-1982 EN-50042-1980.pdf(14页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS 6272:1982 EN 50 042 Specification for Low voltage switchgear and controlgear for industrial use Terminal marking Terminals for external associated electronic circuit components and contacts This European Standard EN 50 042 was given as from 30 September 1982 the status of a Briti
2、sh Standard UDC 621.316.54:621.3.027.2:621.315.684:003.62 Licensed Copy: sheffieldun sheffieldun, na, Tue Dec 05 07:19:27 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 6272:1982 This British Standard was published under the authority of the Board of BSI and comes into effect on 30 September 1982 BSI
3、 07-1999 The following BSI references relate to the work on this standard: Committee reference PEL/10 Draft for comment 79/24447 DC ISBN 0 580 12788 5 Cooperating organizations The European Committee for Electrotechnical Standardization (CENELEC), under whose supervision this European Standard was p
4、repared, comprises the National Committees of the following countries: AustriaLuxemburg BelgiumNetherlands DenmarkNorway FinlandPortugal FranceSpain GermanySweden GreeceSwitzerland IrelandUnited Kingdom Italy Amendments issued since publication Amd. No.Date of issueComments Licensed Copy: sheffieldu
5、n sheffieldun, na, Tue Dec 05 07:19:27 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 6272:1982 BSI 07-1999i Contents Page Cooperating organizationsInside front cover Foreword2 Text of EN 50 0423 National appendixA8 National appendix B8 Publications referred toInside back cover Licensed Copy: sheffie
6、ldun sheffieldun, na, Tue Dec 05 07:19:27 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 6272:1982 ii BSI 07-1999 A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a Brit
7、ish Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, the EN title page, pages 2 to 8, an inside back cover and a back cover. This standard has been updated (see copyright date) and may h
8、ave had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Licensed Copy: sheffieldun sheffieldun, na, Tue Dec 05 07:19:27 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 50 042 Edition 1 December 1980 UDC
9、: 621.316.54:621.3.027.2:621.315.684:003.62 Key words: Electrical switchgear and controlgear, low voltage, industrial use, terminals, marking, external contacts, external electronic components English version Low voltage switchgear and controlgear for industrial use Terminal marking Terminals for ex
10、ternal associated electronic circuit components and contacts Appareillage industriel basse tension Marquage des bornes Bornes pour les composants de circuit lectronique et pour les contacts extrieurs associs Industrielle Niederspannungs-Schaltgerte Anschlussbezeichnungen Klemmen zum Anschluss zugehr
11、iger, aussenliegender elektronischer Bauelemente und Kontakte This European Standard was accepted by CENELEC on 1980-12-11. The CENELEC members are bound to adhere to the CENELEC Internal Regulations which specify under which conditions this European Standard has to be given, without any alteration,
12、 the status of a national standard. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CENELEC General Secretariat or to any CENELEC member. This European Standard is established by CENELEC in three official versions (English, Fre
13、nch, German). A translation made by another member under its own responsibility, in its own language, and notified to CENELEC has the same status. CENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Ireland, Italy, Luxemburg, N
14、etherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels Copyr
15、ight reserved to all CENELEC members Licensed Copy: sheffieldun sheffieldun, na, Tue Dec 05 07:19:27 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 50 042 BSI 07-1999 2 Foreword Switchgear and controlgear may be given a terminal marking in accordance with the general rules of the European Standard EN
16、 50 005. This standard gives additional requirements. Contents Foreword2 1Scope3 2Marking of terminals for external associated electronic circuit components and contacts3 3Marking of terminals of a complete device5 Licensed Copy: sheffieldun sheffieldun, na, Tue Dec 05 07:19:27 GMT+00:00 2006, Uncon
17、trolled Copy, (c) BSI EN 50 042 BSI 07-19993 1 Scope This standard applies to switching devices which are able to operate only when completed with external associated electronic circuit components and contacts. The rules in this standard apply only to terminals for external associated electronic cir
18、cuit components and contacts. These are a supplement to the general rules for the marking: of control supply terminals (see EN 50 005, clause 3.1), and of terminals for internal auxiliary contact elements (see EN 50 005, clause 4.2). The use of this standard is recommended where terminal marking is
19、a requirement of the relevant standard for switching devices or is usual practice. 2 Marking of terminals for external associated electronic circuit components and contacts Terminals for external associated electronic circuit components and contacts shall be marked in the following alpha-numerical m
20、anner. 2.1 Marking of terminals for external associated impedances 2.1.1 The two terminals for an external associated impedance Z shall be marked Z1 and Z2. 2.1.2 For an impedance Z with tappings, the terminals for the tappings shall be marked in sequential order Z3, Z4, etc. 2.1.3 In case of more t
21、han one impedance, the terminals shall be marked by using the letter Z and two-figure numbers, the first figure being a sequence number. Licensed Copy: sheffieldun sheffieldun, na, Tue Dec 05 07:19:27 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 50 042 4 BSI 07-1999 2.1.4 For particular application
22、 to a control system associated with thermistors for built-in thermal protection of rotating electrical machines, the rules for terminal marking T1, T2, . . . or 1T1, 1T2, . . . and 2T1, 2T2, . . . are given in IEC Publication 34-11 (1978), clause 6.2.1. 2.2 Marking of terminals for external associa
23、ted contacts 2.2.1 The two terminals for an external associated make or break contact or a group of contacts shall be marked Y1 and Y2. NOTE 1A bridge between two terminals is considered as a permanently closed contact and the corresponding terminals shall be marked Y1 and Y2. Licensed Copy: sheffie