1、BRITISH STANDARD BS 6955-22: 1997 ISO 5347-22: 1997 Methods for Calibration of vibration and shock pick-ups Part 22: Acceleration resonance testing General methods ICS 17.160 Licensed Copy: sheffieldun sheffieldun, na, Tue Dec 05 05:17:30 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 6955-22:1997 Th
2、is British Standard, having been prepared under the direction of the Engineering Sector Board, was published under the authority of the Standards Board and comes into effect on 15 June 1997 BSI 02-1999 ISBN 0 580 27569 8 National foreword This British Standard reproduces verbatim ISO 5347-22:1997 an
3、d implements it as the UK national standard. The UK participation in its preparation was entrusted to Technical Committee GME/21, Mechanical vibration and shock, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enq
4、uiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The Br
5、itish Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or using the “Find” facility of the BSI Standards Electronic Catalogue. A British
6、 Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front c
7、over, an inside front cover, pages i and ii, the ISO title page, page ii, pages 1 to 3 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publ
8、ication Amd. No.DateComments Licensed Copy: sheffieldun sheffieldun, na, Tue Dec 05 05:17:30 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 6955-22:1997 BSI 02-1999i Contents Page National forewordInside front cover Forewordii 1Scope1 2Normative reference1 3Apparatus1 4Procedure2 Figure 1 Acceleromet
9、er transverse resonance frequency testing2 Figure 2 Accelerometer resonance frequency testing3 Licensed Copy: sheffieldun sheffieldun, na, Tue Dec 05 05:17:30 GMT+00:00 2006, Uncontrolled Copy, (c) BSI ii blank Licensed Copy: sheffieldun sheffieldun, na, Tue Dec 05 05:17:30 GMT+00:00 2006, Uncontrol
10、led Copy, (c) BSI Licensed Copy: sheffieldun sheffieldun, na, Tue Dec 05 05:17:30 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 6955-22:1997 ii BSI 02-1999 Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). Th
11、e work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-gov
12、ernmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. Draft International Standards adopted by the technical committees are circulated to the member bodies for
13、voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. International Standard ISO 5347-22 was prepared by Technical Committee ISO/TC 108, Mechanical vibration and shock, Subcommittee SC 3, Use and calibration of vibration and shock me
14、asuring instruments. ISO 5347 consists of the following parts, under the general title Methods for the calibration of vibration and shock pick-ups: Part 0: Basic concepts; Part 1: Primary vibration calibration by laser interferometry; Part 2: Primary shock calibration by light cutting; Part 3: Secon
15、dary vibration calibration; Part 4: Secondary shock calibration; Part 5: Calibration by Earths gravitation; Part 6: Primary vibration calibration at low frequencies; Part 7: Primary calibration by centrifuge; Part 8: Primary calibration by dual centrifuge; Part 9: Secondary vibration calibration by
16、comparison of phase angles; Part 10: Primary calibration by high impact shocks; Part 11: Testing of transverse vibration sensitivity; Part 12: Testing of transverse shock sensitivity; Part 13: Testing of base strain sensitivity; Part 14: Resonance frequency testing of undamped accelerometers on a st
17、eel block; Part 15: Testing of acoustic sensitivity; Part 16: Testing of mounting torque sensitivity; Part 17: Testing of fixed temperature sensitivity; Part 18: Testing of transient temperature sensitivity; Part 19: Testing of magnetic field sensitivity; Part 20: Primary vibration calibration by th
18、e reciprocity method; Part 21: Shock calibration using laser Doppler velocimeter; Part 22: Accelerometer resonance testing General methods. Descriptors: Vibration, mechanical shock, measurement, measuring instruments, accelerometers, sensors, calibration. Licensed Copy: sheffieldun sheffieldun, na,
19、Tue Dec 05 05:17:30 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 6955-22:1997 BSI 02-19991 1 Scope ISO 5347 comprises a series of documents dealing with methods for the calibration of vibration and shock pick-ups. This part of ISO 5347 lays down detailed specifications for the instrumentation and p
20、rocedures to be used for accelerometer resonance testing. It applies to rectilinear accelerometers of the piezoresistive, piezoelectric and variable capacitance types in the frequency range 50 Hz to 200 kHz. The procedures are in general contrary to those described in ISO 5347-14 which is limited to
21、 undamped accelerometers. The frequency response of a piezoelectric accelerometer depends on the value of the (lowest) resonance frequency of the instrument when mounted on the structure to be tested. It does not appear possible to specify a test which will determine this frequency for all installat
22、ions of a given accelerometer. This procedure gives the accelerometer resonance frequency under a set of standard reproducible conditions, with the understanding that the resonance frequency in actual use will in all probability be appreciably different (generally lower, by a factor depending on the
23、 mass and compliance of the test structure and the method of attachment). The procedure is not suitable for evaluating the mounted resonance frequency for a field of application; a suitable method is given in ISO 5348. 2 Normative reference The following standard contains provisions which, through r
24、eference in this text, constitute provisions of this part of ISO 5347. At the time of publication, the edition indicated was valid. All standards are subject to revision, and parties to agreements based on this part of ISO 5347 are encouraged to investigate the possibility of applying the most recen