1、BRITISH STANDARD BS 5131-4.4: 1990 Methods of test for Footwear and footwear materials Part 4: Other components Section 4.4 Heel pin holding strength of fibreboard NOTEIt is recommended that this Section should be read in conjunction with BS 5131-0, published separately. Licensed Copy: sheffieldun s
2、heffieldun, na, Mon Dec 04 14:08:39 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 5131-4.4:1990 This British Standard, having been prepared under the direction of the Textiles and Clothing Standards Policy Committee, was published under the authority of the Board of BSI and comes into effect on 31 D
3、ecember 1990 BSI 10-1999 First published February 1975 Second edition December 1990 The following BSI references relate to the work on this standard: Committee reference TCM/39 Draft for comment 89/36227 DC ISBN 0 580 18822 1 Committees responsible for this British Standard The preparation of this B
4、ritish Standard was entrusted by the Textiles and Clothing Standards Policy Committee (TCM/-) to Technical Committee TCM/39, upon which the following bodies were represented: British Footwear Manufacturers Federation British Leather Confederation British Rubber Manufacturers Association British Stee
5、l plc Consumer Standards Advisory Committee of BSI Cork Industry Federation Footwear Components Federation Footwear Distributors Federation Institute of Trading Standards Administration Iron and Steel Trades Confederation Lancashire Footwear Manufacturers Association Mail Order Traders Association o
6、f Great Britain Ministry of Defence National Union of Footwear, Leather and Allied Trades Office of Fair Trading SATRA Footwear Technology Centre The following bodies were also represented in the drafting of the standard, through subcommittees and panels: British Adhesives and Sealants Association B
7、ritish Paper and Board Industry Federation British Plastics Federation Multiple Shoe Retailers Association RAPRA Technology Ltd. Amendments issued since publication Amd. No.DateComments Licensed Copy: sheffieldun sheffieldun, na, Mon Dec 04 14:08:39 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 5131
8、-4.4:1990 BSI 10-1999i Contents Page Committees responsibleInside front cover Forewordii 1Scope1 2Principle1 3Apparatus1 4Conditioning1 5Preparation of test specimens1 6Procedure1 7Expression of results3 8Test report3 Figure 1 Compression cage, combining the two parts of the attachment for the tensi
9、le testing machine2 Publication referred toInside back cover Licensed Copy: sheffieldun sheffieldun, na, Mon Dec 04 14:08:39 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 5131-4.4:1990 ii BSI 10-1999 Foreword This Section of BS 5131 has been prepared under the direction of the Textiles and Clothing
10、Standards Policy Committee. It supersedes BS 5131-4.4:1975, which is withdrawn. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself c
11、onfer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 4, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indica
12、ted in the amendment table on the inside front cover. Licensed Copy: sheffieldun sheffieldun, na, Mon Dec 04 14:08:39 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 5131-4.4:1990 BSI 10-19991 1 Scope This Section of BS 5131 describes a method for measuring the ability of a fibreboard to hold a heel p
13、in and to prevent the pin head from being pulled through the fibreboard. The procedure is applicable to fibreboard used in the seat of footwear with inside attached heels, and also to seat components where outside heel attachments are used and the heel pin is clenched. The method may also be applied
14、 to plastics shoe backparts. NOTEThe title of the publication referred to in this standard is given on the inside back cover. 2 Principle The force required to push a simulated heel pin head through the fibreboard is measured both for the dry and the wet fibreboard. 3 Apparatus 1) 3.1 Conditioning c
15、abinet or room, maintaining an atmosphere of 20 2 C and 65 2 % r.h. 3.2 Drill, fitted with twist drill bit of nominal diameter 2.05 mm, actual diameter between 2.040 mm and 2.065 mm inclusive. 3.3 Tensile testing machine, with a range of 0 kN to 2 kN (0 kgf to 200 kgf) and a jaw separation rate of 1
16、00 20 mm/min. 3.4 Attachment for the tensile testing machine, consisting of the following two essential parts. a) Rigid supporting plate for the test specimen, with a 12 1 mm diameter circular hole and a means of attachment to the upper clamp of the machine, so that the line of action of the force a
17、pplied during testing passes through the centre of the hole and is perpendicular to the plate. b) Fitting, providing a means of pushing a rod through the test specimen; the leading part of the rod consists of a 2.0 0.1 mm diameter shank, and the remainder a head of 4.06 0.05 mm diameter. The two sec
18、tions join at a shoulder in the form of a plane perpendicular to the axis of the rod. (These dimensions correspond to those of a 8 14 gauge heel pin.) The attachment is designed to ensure that the axis of the rod passes through the centre of the hole in the test specimen supporting plate. In order f
19、or the tensile testing machine to produce the compression forces, the above two parts of the attachment may conveniently be combined in the form of a compression cage, as illustrated in Figure 1. The rigid supporting plate (A) for the test specimen is suspended from the top clamp of the tensile test
20、ing machine. The fitting (B) is supported by the lower clamp so that the rod (C) (representing the gauge heel pin) is above the supporting plate for the test specimen, and the axis of the rod (C) passes through the centre of the circular hole (D). 3.5 Dial micrometer gauge, standing on a firm base a
21、nd dead-weight loaded such that the presser foot applies a pressure of 49 5 kPa (5.0 0.5 gf/mm2). The gauge has a presser foot which is flat, circular, and 10.0 mm in diameter. The gauge meets the accuracy requirements of BS 907 and has scale divisions of 0.01 mm. 4 Conditioning Place the fibreboard
22、 in the conditioning cabinet or room (3.1). After 48 h, cut the test specimens (see clause 5 for dimensions). 5 Preparation of test specimens Cut from the fibreboard two rectangular test specimens each approximately 80 mm by 20 mm, one test specimen for dry testing (see 6.1) and the other for wet te