BS-5566-1978 IEC-60532-1976.pdf
《BS-5566-1978 IEC-60532-1976.pdf》由会员分享,可在线阅读,更多相关《BS-5566-1978 IEC-60532-1976.pdf(18页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS 5566:1978 IEC 532:1976 Recommendations for Installed exposure rate meters, warning assemblies and monitors for X or gamma radiation of energy between 80 keV and 3 MeV UDC 614.876:539.16.074 + 621.039.4.004.4:654.9 Licensed Copy: sheffieldun sheffieldun, na, Fri Dec 01 13:58:41 GM
2、T+00:00 2006, Uncontrolled Copy, (c) BSI BS 5566:1978 This British Standard, having been prepared under the direction of the Nuclear Engineering Standards Committee, was published under the authority of the Executive Board on 31 August 1978 BSI 12-1999 The following BSI references relate to the work
3、 on this standard: Committee reference NCE/2 Draft for comment 74/43126 DC ISBN 0 580 101202 5 Cooperating organizations The Nuclear Engineering Standards Committee, under whose direction this British Standard was prepared, consists of representatives from the following Government department and sci
4、entific and industrial organizations: Association of Consulting Engineers* British Electrical and Allied Manufacturers Association (BEAMA) British Insurance (Atomic Energy) Committee Electricity Supply Industry in England and Wales* Health and Safety Executive* Hevac Association Institution of Mecha
5、nical Engineers Institution of Nuclear Engineers* Lloyds Register of Shipping National Radiological Protection Board* Scientific Instrument Manufacturers Association* United Kingdom Atomic Energy Authority* Water-tube Boilermakers Association The organizations marked with an asterisk in the above li
6、st, together with the following, were directly represented on the committee entrusted with the preparation of this British Standard: Association of University Protection Officers British Industrial Measuring and Control Apparatus Manufacturers Association British Institute of Radiology British Nucle
7、ar Forum British Steel Industry Business Equipment Trade Association Control and Automation Manufacturers Association (BEAMA) Electronic Engineering Association Hospital Physicists Association Ministry of Defence Society for Radiological Protection Individual companies Amendments issued since public
8、ation Amd. No.Date of issueComments Licensed Copy: sheffieldun sheffieldun, na, Fri Dec 01 13:58:41 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 5566:1978 BSI 12-1999i Contents Page Cooperating organizationsInside front cover National forewordii 1Scope1 2Object1 Section 1. Terminology 3Degrees of r
9、equirements1 4Definitions applicable to this standard1 5Test nomenclature2 Section 2. General requirements 6General2 7Alarms2 8Alarm threshold3 9Classification3 Section 3. General test procedures 10Basic tests3 11Point of test4 12Background radiation4 13Statistical fluctuations4 14Reference gamma ra
10、diation4 Section 4. Radiation characteristics 15Accuracy of response to reference gamma radiation6 16Variation of response with radiation energy7 17Variation of response with angle of incidence8 18Beta radiation8 19Neutron radiation8 Section 5. Electrical characteristics 20Statistical fluctuations8
11、21Response time9 22Interrelationship between response time and statistical fluctuations9 23Zero drift9 24Alarm threshold drift10 25Warm-up10 26Mains voltage10 Section 6. Safety characteristics 27Overload characteristics11 28Ease of decontamination11 Section 7. Environmental characteristics 29Ambient
12、 air temperature11 30Relative humidity11 31Atmospheric pressure11 32Sealing12 Section 8. Documentation to be supplied 33Identification certificate12 Table I Reference conditions and standard test conditions4 Table II Tests performed under standard test conditions5 Table III Tests performed with vari
13、ation of influence quantities6 Publications referred toInside back cover Licensed Copy: sheffieldun sheffieldun, na, Fri Dec 01 13:58:41 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 5566:1978 ii BSI 12-1999 National foreword This British Standard is identical with IEC Publication 532 “Installed exp
14、osure rate meters, warning assemblies and monitors for X or gamma radiation of energy between 80 keV and 3 MeV”. The standard has been prepared under the direction of the Nuclear Engineering Standards Committee and the UK took part in the work of IEC sub-committee 45B that prepared IEC 532. The form
15、al decisions or agreements of the IEC on technical matters, prepared by technical committees on which all the national committees having a special interest therein are represented, express, as nearly as possible, an international consensus of opinion on the subjects dealt with. They have the form of
16、 recommendations for international use and they are accepted by the national committees in that sense. Cross-references. For each of the following International Standards referred to in the text, there is an equivalent British Standard; these are as listed below: NOTEThe reference to IEC 293, for wh
17、ich there is no corresponding British Standard, constitutes informative matter only, but since no mandatory requirements are involved, the validity of this British Standard is not affected. Additional information. The text of the International Standard uses the Rntgen (symbol: R) as the unit of expo
18、sure. While the use of this unit is expected to continue for some time, it is intended that it will eventually disappear in favour of the SI unit of exposure, the coulomb per kilogram (symbol: C/kg). The conversion equation is: 1 R = 258 4C/kg. A British Standard does not purport to include all the
19、necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. International StandardCorresponding British Standard IEC 38:1975BS 77:1958 Voltages for a.c. tra
20、nsmission and distribution systems (Related) IEC 68BS 2011 Basic environmental testing procedures (Identical) IEC 231:1967 IEC 231A:1969 BS 4877:1972 Recommendations for general principles of nuclear reactor instrumentation (Technically equivalent) IEC 278:1968BS 4308:1968 Documents supplied with el
21、ectronic measuring instruments (Identical) Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 12, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be i
22、ndicated in the amendment table on the inside front cover. Licensed Copy: sheffieldun sheffieldun, na, Fri Dec 01 13:58:41 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 5566:1978 BSI 12-19991 1 Scope This standard applies to installed exposure rate meters, warning assemblies and monitors, defined in
23、 Section 1, and intended to measure the exposure rate due to X or gamma radiation of energy between 80 keV and 3 MeV for the purposes of radiation protection. NOTEAssemblies of this type are commonly defined as area radiation monitors. They are normally employed to determine continuously the radiolo
24、gical situation in working areas in which the radiation field may change with time, for example nuclear reactors, particle accelerators, hot laboratories, fuel reprocessing plants, etc., and to provide alarms when the radiation field goes outside predetermined limits. This standard does not apply to