ISO-11075-1993.pdf
《ISO-11075-1993.pdf》由会员分享,可在线阅读,更多相关《ISO-11075-1993.pdf(12页珍藏版)》请在三一文库上搜索。
1、, INTERNATIONAL STANDARD IS0 11075 First edition 1993-07-01 Aerospace - Aircraft de-icing/anti-icing Newtonian fluids, IS0 type I Akonautique et espace - Liquides newtoniens IS0 type I de d 1 - l/2 % Alclad 2024-T35 1 Plate). AMS 4049H, Aluminium Alloy Sheet and Plate, Alclad, 5.6Zn - 2.5Mg - 1.6Cu
2、- 0.23Cr (Alclad 7075-T6 Sheet,-T651 Plate), Solution and Precipitation Heat Treated. AMS 4376E, Magnesium Alloy Plate, 3.OAI - l.OZn (AZ3 I B-H26), Cold Rolled and Partially Annealed. AMS 4911 F, Titanium Alloy Sheet, Strip, and Plate, 6AI - 4V, Annealed. AMS 6350H, Steel Sheet, Strip and Plate, 0.
3、950 - 0.20Mo (0.28-0.33C). I) To be published. (Revision of IS0 3104.1976) 2) To be published. 3) This publication is available from the OECD, 2, rue And Acrylic sheets, panes and moulded parts; Technical specification.8) WL 5.1416:1992, Aerospace; acrylic material, cast, crosslinked, in 5.14 7 5 ma
4、terial, biaxially stretched and crack propagation resistant.s) 3 Definitions For the purposes of this international Standard, the following definitions apply. 3.1 Newtonian fluid: Fluid whose viscosity is shear independent and time independent. The shear rate of a Newtonian fluid is directly proport
5、ional to the shear stress. A Newtonian fluid will begin to move immedi- ately upon application of a stress; it has no yield stress which must be achieved before flow begins. 3.2 lot: All compound produced in a single pro- duction run from the same batches of raw materials under the same fixed condit
6、ions and presented for vendor s inspection at one time. NOTE 1 The compound may be packaged in smaller quantities under the basic lot approval provided lot identifi- cation is maintained. 3.3 preproduction test: Test to determine con- formance to all technical requirements of this Inter- national St
7、andard. 3.4 acceptance test: Test performed to determine conformance to the requirements given in 4.2.6, 4.2.7 and 4.2.10. 3.5 periodic test: Test to determine conformance to the requirements given in 4.2.8.2 and 4.5. 4 Performance requirements 4.1 Composition The fluid shall contain a freezing-poin
8、t depressant. The composition of the fluid shall otherwise be at the manufacturer s discretion. The fluid may contain ad- ditives, provided the requirements of this International Standard are met. When glycols are used as the freezing-point depressant, the fluid shall include an inhibitor to mini- m
9、ize the potential fire hazard resulting from the inter- action between aqueous glycol solutions and noble 5) ASTM standards are available from American Society of Testing and Materials, 1916 Race Street, Philadelphia, PA 19103, USA 6) Available from Boeing Company. 7) US Government Publications are
10、available from the Commanding Officer, Naval Publications and Forms Center, 5801 Tabot Avenue, Philadelphia, PA 19120, USA. 8) Available from DIN (Deutsches lnstitut ftir Normung, e.V 1, Postfach, D-10772 Berlin, Germany 2 Copyright International Organization for Standardization Provided by IHS unde
11、r license with ISO Licensee=NASA Technical Standards 1/9972545001 Not for Resale, 04/23/2007 21:43:06 MDTNo reproduction or networking permitted without license from IHS -,-,- IS0 11075:1993(E) metal electrodes impressed with a direct current po- tential. Slippery conditions can be present following
12、 the de- icing procedure. Caution should be exercised, par- ticularly under low humidity or non-precipitating weather conditions. The fluid shall meet local re- quirements for pavement compatibility. NOTE 2 Pavement compatibility requirements will be specified after the US Federal Aviation Agency (F
13、AA) has established a standardized test method. 4.2 Properties The fluid shall have 4.2.1 Flash point the following properties. The flash point shall not be lower than 100 “ C (212 “ F), determined in accordance with IS0 2719. 4.2.2 Specific gravity The specific gravity shall be within f I,5 % of th
14、e nominal value, determined in accordance with IS0 3675. 4.2.3 Storage stability The fluid as delivered shall offer enough stability to guarantee 2 years storage in an airport environment. Compliance with this requirement shall be demon- strated by testing the fluid in accordance with ASTM F 1104. T
15、he fluid shall show neither separation from exposure to heat or cold nor an increase in turbidity greater than a freshly-made control sample diluted 1 + 1 with ASTM D 1193 Type IV water. The hot test shall be conducted at 80 “ C f 2 “ C (176 “ F f 3,6 “ F) for a duration of 30 d. The cold test shall
16、 be conducted for a duration of 30 d. 4.2.4 Hard water compatibility The fluid diluted 1 + 1 with standard hard water (as specified in 4.2.4.1) when submitted to the stability test specified in 4.2.4.2, shall not show any insoluble deposit or increase in turbidity greater than the freshly made contr
17、ol sample diluted 1 + 1 with ASTM D 1193 Type IV water. The pH of the tested sample shall be within st 0,5 of the initial value. 4.2.4.1 Composition of standard hard water Dissolve 400 mg f 5 mg of calcium acetate (CH,COO),Ca.2H,O and 280 mg b) fluid diluted 1 + 1 with ASTM D 1193 Type IV wa- ter. 4
18、.3.1 Corrosion of metal surfaces 4.3.1 .l Sandwich corrosion Specimens, after test, shall not show a sandwich corrosion rating worse than 1 or worse than reagent water, when tested in accordance with ASTM F 1110. 4.3.1.2 Total immersion corrosion The fluid shall neither show evidence of corrosion no
19、r cause a change in mass per unit area of any test panel greater than that given in table 1, when tested in ac- cordance with ASTM F 483. Table 1 - Maximum permitted daily change in mass per unit area Maximum Test panel Relevant standard permitted daily change mg/cm Aluminium alloy, anodized in acco
20、rdance with AMS 2470 AMS 4037 0,3 Aluminium alloy AMS 4041 0,3 Aluminium alloy AMS 4049 0,3 Magnesium alloy, dichromate treated in ac- AMS 4376 02 cordance with AMS 2475 Titanium alloy AMS 4911 O,l Carbon steel, temper 5 ASTM A 109 W Steel, cadmium plated, in accordance with BAC 5718 AMS 6350 0,3 4.
21、3.1.3 Low-embrittling cadmium plate Test panels coated with low-embrittling cadmium plate shall not show a daily change in mass per unit area greater than 0,3 mg/cm* in accordance with ASTM F 1111. 4.3.1.4 Stress corrosion resistance 4.3.1.5 Hydrogen embrittlement The fluid shall be non-embrittling,
22、 when tested in ac- cordance with ASTM F 519 using a test specimen of either type la, Ic or 2a. 4.3.2 Effect on plastic 4.3.2.1 Effect on acrylic material The fluid, when heated to 65 “ C + 2 “ C (149 “ F f 3,6 “ F), shall not craze, stain or discolour DIN 65 321, stretched WL 5.1416 acrylic materia
23、l when tested in accordance with ASTM F 484. 4.3.2.2 Effect on polycarbons The fluid shall not craze, stain or discolour MIL-P-83310 polycarbonate plastic when tested using the general procedure specified in ASTM 484 except that the specimen shall be stressed for 30 min of: 2 min to an outer fibre s
24、tress level of 13,793 MPa (2 000 psi). 4.3.3 Effect on painted surfaces 4.3.3.1 A painted surface, to which the fluid has been applied for 7 d at 22 “ C (71,6 “ F), shall withstand a load of 1 200 g when tested in accordance with IS0 1518. 4.3.3.2 The fluid, heated to 65 “ C f 2 “ C (149 “ F f 3,6 “