1、UDC 681.114:626.02 JIS JAPANESE I NDUSTRIAL STANDARD Divers watches - Classification and performance I 7 - - Translation without guarantee In the event of any doubt arising, the original I I I standard in Japanese is to be evidence Translated Japanese Standards Association 1-24, Akasaka 4, Minato-ku
2、 Tokyo 107 Japan 0 JSA, 1993 PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/10/2007 22:18:17 MSTNo reproduction or networking permitted without license from IHS -,-,- UDC 68
3、1.114: 626. 02 JAPANESE INDUSTRIAL STANDARD J I S Divers watches - Classification and performance 3 7023-1993 1. Scope This Japanese Industrial Standard specifies the classification and performance of watches used for diving (hereafter called “divers watches”) in which time management is necessary.
4、Remarks 1. This Standard does not apply to the watches used in skin div- ing. 2. The following standards me cited in this Standard: JIS B 7001 Testing methods for watches and clocks JIS B 7010 Nomenclature for parts of watches and clocks 3. Corresponding International Standard to this Standard is gi
5、ven as follows: IS0 6425: 1984 Divers watches 2. Definition of terms definitions in JIS B 7010 apply, and the rest of the terms shall be as follows: For the main terms used in this Standard the air diving breathe. mixed-gas diving comprised of an inert gas like helium and oxygen, is used to breathe.
6、 Shallow sea diving in which compressed air is used to Deep sea diving in which high-pressure mixed-gas saturation diving high pressure mixed-gas. time pre-selecting device display device to set time measurement, water resistibility to overpressure of water into the watch when it is subjected to wat
7、er pressure. immersion resistibility into the watch when it is immersed in water. water resistibility of operating parts The ability to prevent the penetra- tion of water into the watch when operating parts are subjected to external force in water. thermal shock resistibility water into the watch wh
8、en it is subjected to sudden changes of temperature in water. Deep sea diving in which divers are saturated with A device that uses a rotating bezel, digital The ability to prevent the penetration The ability to prevent the penetration of water The ability to prevent the penetration of resistance to
9、 helium atmospheres when the watch is subjected for a long time to a high-pressure mixed gas comprised primarily of helium. The ability to function normally even Related standard: JIS 3 7021 Classification and water resistibility of water resistant watches for general use PROTECTED BY COPYRIGHT Copy
10、right Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/10/2007 22:18:17 MSTNo reproduction or networking permitted without license from IHS -,-,- 2 I 3 7023-1993 Type (10) residual effect (il) rate The differ
11、ence of rates before and after testing. The measurement of watch precision in a short time, and the conversion of that measurement into a numerical value indicating the amount of gain or loss per day. Us e Depth grade 3. Classification types depending on the purpose for which they are used. As shown
12、 in Table 1, divers watches are classified into two Type 2 Table 1. Classification and uses of divers watches Watches used for mixed-gas diving such as saturation diving and the like. 200 m and over every 100 m Watches used for air diving such as scuba diving and the like m, 150 m, 2oo Remarks: Scub
13、a diving is defined as “water diving in which breathing apparatus consisting of gas tank, regulator, etc. are provided for personal use.“ 4. Performance 4.1 General provided with the performance specified in clauses 4.2 to 4.11. However, clause 4.11 does not apply to type 1 divers watches. Type 1 di
14、vers watches and type 2 divers watches shall be 4.2 Visibility when tested according to clause 6.4.1. The following things shall be clearly visible on divers watches (1) Indicated time (2) (3) Elapsed time or remaining time on the time pre-selecting device Running of watch (movement of the second ha
15、nd, blinking of the second colon, etc.) 4.3 Antimagnetic property Divers watches shall meet the following require- ments when tested in accordance with Annex 3 (Testing of antimagnetic property) of JIS B 7001. (1) (2) The watch doesnt stop during magnetizing test. Residual effect of mechanical watch
16、es shall be below the following values. (a) (b) For movements with a casing diameter exceeding 920 mm (round type) or an area exceeding 314 rnm2 (all other types): For movements with a casing diameter of 020 mm or less (round type) or an area of 314 mm2 or less (all other types): 30 s/day 45 s/day 4
17、.4 Shock resistance Divers watches shall meet the following requirements when tested in accordance with Annex 4 (Testing of shock resistance) of JIS B 7001. PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=W
18、ing, Bernie Not for Resale, 03/10/2007 22:18:17 MSTNo reproduction or networking permitted without license from IHS -,-,- 3 B 7023-1993 (1) (2) The watch doesnt stop when subjected to physical shocks. Residual effect of the watch shall be below the following values. (a) Mechanical watch: 60 s/day (b
19、) Quartz watch: 2 s/day The function shall not show changes by shock. (3) 4.5 Salt water resistance The case and attachments of divers watches shall not show signs of rust or the like and their moving parts shall function normally after testing has been performed in accordance with 6.4.3. 4.6 merged
20、 such as the time pre-selecting device and the switch for internal light shall function normally when tested in accordance with 6.4.4. Operation in water The essential mechanism to be operated when sub- 4.7 Resistance to an external force 4.7.1 Attachments displaced when the watch is tested in accor
21、dance with 6.4.2. No item shall become detached from the watch or be 4.7.2 Water resistance of operating parts (crowns and other operating parts) No condensation shall be observed on the interior surface of the glass and the mechanism shall function normally when tested in accordance with 64.6. Rema
22、rks: The watch shall be considered to pass the test if the condensation disappears within 60 s when tested according 6.4.9. Hereafter, this criterion shall apply to all cases of condensation. 4.8 Resistance to thermal shock on the interior surface of the glasses and shall function normally when test
23、ed in accordance with 6.4.5. Divers watches shall not show condensation 4.9 show condensation on the interior surface of the glasses and shall function normally when tested in accordance with 6.4:.7. Resistance to water overpressure and tightness Divers watches shall not 4,lO Immersion resistibility
24、 Divers watches shall not show condensation on the interior surface of the glasses and shall function normally when tested in accordance with 6.4.8. 4.11 Resistance to helium atmospheres result in the abnormality of mechanism such as failure of the function, detachment of the glasses, etc. when test