1、JAPANESE INDUSTRIAL STANDARD Translated and Published by Japanese Standards Association JIS K 0098:1998 Methods for determination of carbon monoxide in flue gas ICs 13.040.40 ; 71.040.40 Descriptors : carbon monoxide, exhaust gases, industrial air pollutants, gas analysis, gas chromatography, gas de
2、tectors, infrared radiation, determination of content Reference number : JIS K 0098 : 1998 (E) 6 s Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/12/2007 08:23:05 MDTNo reproduction or networking
3、permitted without license from IHS -,-,- - STD-JIS K 0098-ENGL 1998 Y933bO8 0551835 b38 M K 0098 : 1998 Foreword This translation has been made based on the original Japanese Industrial Standard revised by the Minister of International Trade and Industry through deliberations at Japanese Industrial
4、Standards Committee in accordance with the Industrial Standardization Law: Date of Establishment: 1970-05-01 Date of Revision: 1998-03-20 Date of Public Notice in Official Gazette: 1998-03-20 Investigated by: Japanese Industrial Standards Committee Divisional Council on Environment Technical Committ
5、ee on Air Quality - JIS K 0098:1998, First English edition published in 1998-10 Translated and published by: Japanese Standards Association 4-1-24, Akasaka, Minato-ku, Tokyo, 107-8440 JAPAN In the event of any doubts arising as to the contents, the original JIS is to be the final authority. c O JSA
6、1998 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. Printed in Japan Copyright Japanese Standards
7、 Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/12/2007 08:23:05 MDTNo reproduction or networking permitted without license from IHS -,-,- STDmJIS K DO9-ENGL 1998 W 4933b0 055183b 574 = JAPANESE INDUSTRIAL STANDARD JIS K 0098
8、 : 1998 Methods for determination of carbon monoxide in flue gas 1 Scope This Japanese Industrial Standard specifies the methods for determination of carbon monoxide in flue gas exhausted to flue, chimney, duct, etc., (hereafter referred to as “duct” ) following combustion of fuel, metal refining, c
9、hemical reaction process, Remarks : The normative references to this Standard are shown in Attached Table 1. etc. 2 Common items The common items concerned with chemical analysis, calibration method of gas analyzer, sampling method of flue gas, gas chromatographic analysis shall be in accordance wit
10、h JIS K 0050, JIS K 0055, JIS K 0095 and JIS K 0114 respec- tively. Remarks : Unit ppm in this standard shall be volppm. 3 tion and their outline shall be according to Table 1. Classification of analytical methods and their outline The methods for determina- Table 1 Classification of analytical meth
11、ods and their outlines Methods of determination Outlines of analytical method kpplicable :ondition Summary Sampling Range of deter- mination TCD: 0.1 % min. FID: O ppm to 2 O00 ppm Gas chroma- tography Obtain the concentration of carbon monoxide according to absolute working curve method by using a
12、gas chromatograph provided with thermal conductivity detector (TCD) or methana- tion reaction apparatus and hydrogen flame ionization detector (FID). The syringe meth- od or collecting bag method Gas-detector tube method Obtain the concentration of carbon monoxide by using a gas-detector tube type m
13、easuring device. The collecting bag method or gas- detector tube method 5 ppm to 100 ppm, 50 PP to 1 O00 ppm, 1 O00 ppm min. In accordance with 6 . 1 Infrared ab- sorption method Obtain the concentration of carbon monoxide by using infrared gas analyzer. The collecting bag method or continu- ous mea
14、surement (O ppm to 250 ppm) up to (O % to 1 %) Controlled potential elec- trolysis Obtain the concentration of carbon monoxide by using a controlled potential elec- trolysis analyzer. The collecting bag method or continu- ous measurement (O ppm to 20 ppm) up to (O % to 3 %) In accordance with 8.1 4
15、Gas sampling method Gas sampling method shall be as follows. 4 . 1 Sampling position of gas for analysis shall be selected the point where the typical gas is collected, for example the position where the flow rate Sampling position of gas Copyright Japanese Standards Association Provided by IHS unde
16、r license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/12/2007 08:23:05 MDTNo reproduction or networking permitted without license from IHS -,-,- STD-JIS K 0098-ENGL 3798 D 4933b08 0553837 400 m 2 K 0098 : 1998 of gas does not remarkably change. 4 . 2 Classificatio
17、n of gas sampling method Gas sampling method shall be according to the syringe method and collecting bag method. However, gas sampler may be used for the gas detector tube method. 4 . 3 Method with the syringe This method shall be applied for the gas chromatograph method. c 4 . 3 . 1 method shall be
18、 as follows. Device and apparatus Device and apparatus which is used with the syringe (1) Syringe The syringe having a capacity of 100 ml specified in JIS T 3201. Volumet- ric error for the instrument shall be examined according to 9 . 3 . 1 in JIS K 0050. (2) Gas sampling apparatus Gas sampling app
19、aratus shall have the mechanism as shown in Fig. 1 and provided with the following requirements. (a) Use the gas sampling tube for example glass tube, stainless steel tube, quartz tube, or fluoride resin tube which are not corroded by coexisting component in flue gas, (b) For prevention of the dust
20、to mix with the sample gas, put filter medium into suitable portion of the gas sampling tube. (c) Fearing that the moisture in sample gas might become condense, heat the sam- pling tube at approx. 120 C. (d) For connection of tubes at heating part, use ground glass joint or silicone rubber tube. 4 .
21、 3 . 2 Operation of sampling The sampling of gas with the syringe method shall be carried out according to the following procedure. The symbols of the apparatus shown in following sentences are the same ones in Annex Fig. 1. Turn the three way stop cock (G) to the horizontal direction () and start t
22、he suc- tion pump. Connect the syringe (H) removed injection needle with three way stop cock (G) by rubber tube. Open the three way stop cock (G) in all directions ( e ) . Repeat suction and pushing-out of the syringe (H) several times to displace the in- side of the syringe sufficiently with sample
23、 gas. Take the sample gas in the syringe (H). Close the three-way cock, and remove the syringe. Quickly attach the needle to the syringe and stick a rubber piece to the needle tip. Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=
24、Wing, Bernie Not for Resale, 03/12/2007 08:23:05 MDTNo reproduction or networking permitted without license from IHS -,-,- 3 K 0098 : 1998 A : Gas sampling tube B : Insulating material C : Filter medium D : Heater E : Silicone rubber F : Trap G : Three-way cock H : Syringe I : Desiccant J : Suction