JIS-H-1650-1988-R2004-ENG.pdf
《JIS-H-1650-1988-R2004-ENG.pdf》由会员分享,可在线阅读,更多相关《JIS-H-1650-1988-R2004-ENG.pdf(8页珍藏版)》请在三一文库上搜索。
1、J I S Hm1650 B8 = 4933bOB 0051328 5 f- ., UDC 669.296 t 669.296.5 : 543 JIS. JAPANESE INDUSTRIAL STANDARD General Rules for Chemical Analysis of Zirconium and Zirconium Alloys o Translated and Published by Japanese Standards Association Printed in Japan Copyright Japanese Standards Association Provi
2、ded by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/10/2007 23:37:47 MSTNo reproduction or networking permitted without license from IHS -,-,- J I S H*3650 8 1 4 E 4933b08 0053329 7 E In the event of any doubt arising, the original Standard in Jap
3、anese is to be final authority. . Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/10/2007 23:37:47 MSTNo reproduction or networking permitted without license from IHS -,-,- J I S H*1bSO 88 4933608
4、0051330 3 E UDC 669.296+669.296.5):543 I JAPANESE INDUSTRIAL STANDARD J I S General Rules for Chemical Analysis of H 1650-1988 Zirconium and Zirconium Alloys 1. Scope This Japanese Industrial Standard specifies general rules common to the chemi- cal analysis of zirconium and zirconium alloys. 2. Def
5、initions The definitions of principal terms used in this Standard shall be in accordance with JIS K 0211 and JIS Z 8402. 3. General Matters General matters common to the methods for chemical analysis shall be in accordance with JIS K 0050, JIS K 0115, JIS K 0116, JIS K O119 and JIS K 0121. 4. Sampli
6、ng and Treating of Analytical Sample 4.1 Sampling 4.1.1 Preparation Method for Chlorine Analysis Sample of Sponge Zirconium The preparation method of chlorine analysis sample of sponge zirconium shall be as follows: (3) (4) Take a sample representing a lot from the lot and reduce it to about 1 kg. f
7、or particle size not to be biased, insert a punch thereinto from the upper side and execute compressing forming with a compressor. a pressure as little as possible to an extent that a compressed lump does not collapse. Then, put the reduced sample into a clean die taking care Make Take the compresse
8、d lump out from the die, attach it to the chuck of drilling machine, use a clean drill (25 mm in diameter) and drill it at a number of revolutions and a cutting speed to an extent that the sample is not overheated to be oxidized. Allow the number of increment to be sampled from the compressed lump t
9、o be three pieces. Do not use fats and oils and other lubricants in drilling operation and do not pour water to cool it. Discard chips of 5 to 10 mm in surface part of the compressed lump and collect chips obtained until the drill reaches a depth of 5 to 10 mm from the surface of the compressed lump
10、. Transfer the chips into a container made of zirconium or stainless steel and stamp it with a rod made of zirconium or stainless steel to granulated pieces of not more than 4760 pm specified in JIS Z 8801. Thereafter, remove mixed iron content by using a magnet. When the quantity of chips is much,
11、reduce it to about 20 g by using a riffle sampler or other method to prepare a test sample. Applicable Standards and Reference Standards: .See pages 3, 4 and 5 e Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not fo
12、r Resale, 03/10/2007 23:37:47 MSTNo reproduction or networking permitted without license from IHS -,-,- 2 H 1650-1988 4.1.2 Preparation Method for Analysis Sample (Excluding That for Determina- tion of Chlorine) of SDonne Zirconium The meDaration method for an analvsis AV sample (excluding that for
13、determination of chodne) of zirconium shall be ai follows: (1) Take a sample representing a lot from the lot and reduce it to about 1 kg. Then, divide the reduced sample by using a riffle sampler, prepare six samples of about 150 g, fuse each of them by vacuum arc and prepare six pieces of zirconium
14、 buttons of about 50 mm in diameter and 10 mm in thickness. (2) Remove the adhering substances on a surface by using a brush or the like. After washing with acetone, cut a surface layer of 1 to 2 mm by using a lathe to be removed. Allow X-ray fluorescence analysis to be carried out by using those bu
15、tton samples. (3) Sample chips from the cut surface of each button sample by drilling to reaching 1 to 2 mm from the back surface in accordance with 4.1.1 (2), as appropriate. However, use a drill of 25 mm in diameter and allow the number of increment to be sampled from one piece of button to be one
16、 increment. (4) Transfer the chips into a container made of zirconium or stainless steel, and stamp it with a rod made of zirconium or stainless steel, or otherwise cut it to granulated pieces of not more than about 5 mm by using a cutter or the like. content and sufficiently mix it. a magnet to pre
17、pare an analysis sample, Preparation Method for Analysis Sample of Zirconium and Zirconium Thereafter, combine one lot Remove mixed iron content by using 4.1.3 Alloy Ingot nium alloy ingot shall be as follows: The preparation method for analysis sample of zirconium and zirco- (1) Carry out surface c
18、utting over whole the side of an ingot with a lathe and remove the contaminated portion of the surface. (2) Cut the ingot at three positions at the same interval with a lathe excepting portion of 5 cm wide from both sides on the side and sample about 50 g of chips respectively from said three positi
19、ons, (3) Treat respective chips in accordance with 4.1.2 (4), as appropriate, to prepare an analysis sample. 4.1.4 Preparation Method for Analysis Sample of Zirconium and Zirconium The preparation method for analysis sample of zirconium Alloy Work Materials and zirconium alloy work materials shall b
20、e as follows: (1) Remove adhering substances on a surface by using a brush or the like. After cleaning, take chips by cutting or disconnecting them by using tools such as a lathe, metal scissors, etc. (2) Treat the sampled chips in accordance with 4.1.2 (4), as appropriate, and take them as an analy