1、J IS JAPANESE I N DUSTRIAL STA N DA R D Translated and Published by Japanese Standards Association Methods of radiographic examination for welded joints in aluminium ICs 19.100; 25.160.40; 77.150.10 Reference number : JIS Z 3105 : 2003 (E) PROTECTED BY COPYFUGHT 16 S Copyright Japanese Standards Ass
2、ociation Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/13/2007 23:09:27 MDTNo reproduction or networking permitted without license from IHS -,-,- Z 3105 : 2003 Foreword This translation has been made based on the original Japanese Indus
3、trial Standard revised by the Minister of Economy, Trade and Industry through deliberations at the Japanese Industrial Standards Committee, as the result of proposal for revision of Japanese Industrial Standard submitted by The Japan Light Metal Welding and Construction Association (JLWA) with the d
4、raft being attached, based on the provision of Article 12 Clause 1 of the Industrial Standardization Law applicable to the case of revision by the provision of Article 14. Consequently JIS Z 3105 : 1993 is revised, and further, JIS Z 3108 : 1986 and JIS Z 3109 : 1988 are withdrawn and integrated int
5、o this Standard. Date of Establishment: 1968-09-01 Date of Revision: 2003-03-20 Date of Public Notice in Official Gazette: 2003-03-20 Investigated by: Japanese Industrial Standards Committee Standards Board Technical Committee on Welding JIS Z 3105 : 2003, First English edition published in 2004-05
6、Translated and published by: Japanese Standards Association 4-1-24, Akasaka, Minato-ku, Tokyo, 107-8440 JAPAN In the event of any doubts arising as to the contents, the original JIS is to be the final authority. O JSA 2004 All rights reserved. Unless otherwise specified, no part of this publication
7、may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. Printed in Japan PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee
8、=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/13/2007 23:09:27 MDTNo reproduction or networking permitted without license from IHS -,-,- Z 3105 : 2003 1 2 3 4 5 6 6.1 6.2 6.3 6.4 6.5 6.6 7 7.1 7.2 7.3 7.4 8 9 9.1 9.2 10 11 Contents Page Scope Normative references Definitions Type o
9、f image quality of radiographs Test engineer Radiographic devices and attachment . Radiographic devices . Photo-sensitive materials . Penetrameter Contrastmeter Viewing illuminator Densitometer Photographing method of the radiographs . Combination of the radiation sources and the sensitive materials
10、 Symbols . Irradiation field . Photographing method Necessary conditions of radiographs Observation of radiographs . Viewing illuminator Observation method Classification method of defect image . Records Annex 1 (normative) Photographing method for fusion welded butt joint of aluminium plates and ne
11、cessary conditions of radiographs . 1 1 1 1 2 2 2 2 2 2 3 3 3 3 3 3 3 3 4 4 4 4 4 6 PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/13/2007 23:09:27 MDTNo reproduction or net
12、working permitted without license from IHS -,-,- Z 3105 : 2003 Annex 2 (normative) Photographing method for circumferential welded joint of aluminium pipe and tubes, and necessary conditions of radiographs . 10 Annex 3 (normative) Photographing method for T welded joint of aluminium plates, and nece
13、ssary conditions of radiographs . 19 Annex 4 (normative) Classification method of defect images by the radiographs . 23 (ii) PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/1
14、3/2007 23:09:27 MDTNo reproduction or networking permitted without license from IHS -,-,- JAPANESE INDUSTRIAL STANDARD JIS Z 3105 : 2003 Methods of radiographic examination for welded joints in aluminium 1 Scope This Japanese Industrial Standard specifies the methods of radiographic examination for
15、welded joints of aluminium and aluminium alloys (hereafter referred to as “aluminium”), where the X-ray or yray (hereafter referred to as “radiation”) is carried out by the direct photographing method with the industrial X-ray film. 2 Normative references The following standards contain provisions w
16、hich, through reference in this Standard, constitute provisions of this Standard. The most recent editions of the standards (including amendments) indicated below shall be applied. JIS H 4000 JIS K 7627 JIS Z 2300 JIS Z 2306 JIS Z 3861 JIS Z 4560 JIS Z 4561 JIS Z 4606 Aluminium and aluminium alloy s
17、heets and plates, strips and coiled sheets Non-destructive testing-Industrial radiographic films-Part 1 : Clas- sification of film systems for industrial radiography Terms and definitions of nondestructive testing Radiographic image quality indicators for non-destructive testing Standard qualificati
18、on procedure for radiographic testing technique of welds Industrial y-ray apparatus for radiography Viewing illuminators for industrial radiograph Industrial X-ray apparatus for radiographic testing 3 Definitions 2300 and the following definitions apply. a) For the purposes of this Standard, the def
19、initions given in JIS Z thickness of base metal Nominal thickness of aluminium plate to be used. In the case where the thickness of the base metal is different for fusion welded butt joint, the small thickness shall be used. test part Parts where the weld metal and the heat affected zone for test ta
20、r- get. b) 4 Type of image quality of radiographs The image quality of the radiograph is classified into 6 classes such as Class A, Class B, Class PO, Class P1, Class P2 and Class F. These image qualities shall be applied according to table 1 for each shape of the welded joints. PROTECTED BY COPYRIG
21、HT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/13/2007 23:09:27 MDTNo reproduction or networking permitted without license from IHS -,-,- 2 Z 3105 : 2003 Table 1 Applicable range for image qual
22、ity of radiographs Shape of welded joint Class P1 Class P2 5 Test engineer The engineers to carry out the radiographic test shall be those who have passed the test specified in JIS Z 3861 or those with the capability equal to or higher than them. 6 Radiographic devices and attachment 6.1 The radiogr
23、aphic devices shall be an X-ray devices specified in JIS Z 4606, and a y-ray devices specified in JIS Z 4560 or the devices with the performance equal to or higher than those. Radiographic devices 6.2 Photo-sensitive materials Industrial X-ray film (hereafter referred to as “film”) shall be used fil
24、m system Class Tl (low sensitivity, super ultra-fine particles), Class T2 (low sensitivity, ultra-fine particles), Class T3 (medium sensitivity, fine particles), or Class T4 (high sensitivity, fine particles) specified in JIS K 7627. A lead foil intensifying screen shall be used for the intensifying