1、UDC 6 1 5 . 4 7 3 . 2 JIS JAPANESE I NDUSTRIAL STANDARD I n j e c t i o n Needles Jls T 3 1 0 1 - 1 9 7 9 (Reaffirmed: 1 9 8 5 ) -1 _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ - _ - - - - - - - - 1 Translation without guarantee In the event of any doubt arising, the original I I I I I standard i n Japanese is t
2、o be evidence ; _- J Transia ted Japanese Standards Association 1-24, Akasaka 4, Minato-ku Tokyo 107 Japan 8 JSA, 1987 PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/11/2007
3、 07:52:41 MDTNo reproduction or networking permitted without license from IHS -,-,- This English translation i s prepared at the expense of Japan External Trade Organization (JETRO) . PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS E
4、mployees/1111111001, User=Wing, Bernie Not for Resale, 03/11/2007 07:52:41 MDTNo reproduction or networking permitted without license from IHS -,-,- UDC 615.473.2 JAPANESE INDUSTRIAL STANDARD J I S Injection Needles T 3101-1979 (Reaffirmed: 1985) 1. Scope This Japanese Industrial Standard specifies
5、injection needles for the purpose of medical treatment, hereinafter referred to as the “injection needles“. Remark: The units and numerical values given in I 1 in this standard are in accordance with the International System of Units (SI), and are appended for reference. 2. Class, Dimension of Needl
6、e and Angle of Point The class, dimension of needle and angle of point shall be as given in Table 1. Applicable Standards: JIS G 4305-Cold Rolled Stainless Steel Plates and Sheets JIS G 4805-High Carbon Chromium Bearing Steels JIS H 3250-Copper and Copper Alloy-Rods and Bars JIS H 4160-Aluminium and
7、 Alluminium Alloy Foils PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/11/2007 07:52:41 MDTNo reproduction or networking permitted without license from IHS -,-,- 2 T 3101-19
8、79 +o M +O. o2 O. 8 : : : 0- 6-0: o1 0.7-0.01 Table 1. Class, Dimension of Needle and Angle of Point 30 f 1 18 33 i: 1 18 35 f 1 18 Class +O. 02 +o 02 1 . 0 : ; : ; ; +o o2 0.8-0. o1 0-8-0:01 1.5-0:01 H4 H5 H6 H7 so* 1.5 14 6 0 f l . S 14 60f 1.5 14 80 f 2 14 V6 v7 V8 +o 02 +o 02 0.4-0: o1 0- 5-0:oi
9、 o. 6+o.02 O. 6 : ; ; -0.01 0-7-0.01 +0.02 v 10 v 11 v 12 v 15 M8 MI 8 M 10 M 15 20 f 1 25 23 f 1 25 26 f 1 25 3 3 f 1 1 20 30f 1 I 20 L4 L6 L? Li 7 L8 s7 S I 7 S8 D4 D5 D6 DI 6 D7 Application Subcutaneous injection Intravenous injection Intravenous injection and blood transfusion (inclusive of thos
10、e attaching stable plate ) ntrmascular injection and pus aspiration Local anaesthesia and tor hinolo gy Local anaesthesia Local anaesthesia and itorhinology Locai anaesthesia Lumbar anaesthesia (hub 3haii be of mandolin with ugs) ;ocai anaesthesia in ientai surgery Cransmission anaesthesia n dentai
11、sermrv ,ocal anaesthesia in lentai surgery Note (l) The angle of point shows the standard. Remarks 1. In case of exports only, the class, dimension of needle, angle of point and dimension of hub recess, when specified specifically by the purchaser, may be modified in proportion to this standard. 2.
12、The shape of points shall be the two types of straight and curved forms, and the angle e of points conform to Fig. 1. PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/11/2007
13、07:52:41 MDTNo reproduction or networking permitted without license from IHS -,-,- 3 T 3101-1979 Outer diameter of needle mm Under O. 6 O. 6 and over Fig. f Shape of Point Pulling load kgf N 1 Z(19.61 3t29.4) Hub Straight form - 3 . Efficiency of Needle 3.1 Inner and Outer Surfaces shall be as follo
14、ws: - Curved .form a - The inner and outer surface of needle (1) The outer surface shall be smoothly finished free from unevenness and flaws. (2) The inner surface shall be free from flaws, polishing dust and adhe- sion of oxide flakes, dust, etc.- (3) The point shall be ground sharply and free from
15、 burrs. (4) When inspected in conformity to the method for inspection under 6.3 (1) , glycerin shall not develop a colour. 3.2 Elasticity of Needle When needles of outer diameter not more than 1. O mm is inspected in conformity to the method for test under 6.4, the needle shall return to the origina
16、l position. 3.3 Bending Strength of Needle The needle shail, when subjected to the test in conformity to the method for test under 6.5, shall not break. 3.4 Pulling Strength of Needle When tested in conformity to the method for test under 6.6, the needle shall withstand the numerical value specified
17、 in Tbale 2. Table 2. Pulling Strength PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/11/2007 07:52:41 MDTNo reproduction or networking permitted without license from IHS -,
18、-,- 4 T 3101-1979 3.5 Sharpness of Needle The needle shall, when being subjected to a test in compliance with method for test under 6.7, conform to the numerical value specified in Table 3. Table 3 Resistance for Class 1 penetration *f N H 4 H 5 H6 H7 15 O. 147) max. 1 5 O . 1 4 7 max. 17 O. 167) ma
19、x. 170.167) max. v 4 v7 V8 v 1 0 v 11 v 12 v 1 5 17 O. 1 6 7 1 max. 20 o. 1 9 6 1 max. 23 O . 2 2 6 1 max. 24 ( O . 2 3 5 1 max. 25 O . 245 max. 28 O . 275 max. 17 O. 167 max- M8 Mi 8 M 10 M 15 19 O . 1 8 6 1 max. 22 o. 2 1 6 1 max. 27 O. 2 6 5 1 max. 19 O. 186 max- L 4 L6 L7 LI 7 a s7 s i 7 S 8 D 4