JIS-Z-8719-1996-R2007-ENG.pdf
《JIS-Z-8719-1996-R2007-ENG.pdf》由会员分享,可在线阅读,更多相关《JIS-Z-8719-1996-R2007-ENG.pdf(29页珍藏版)》请在三一文库上搜索。
1、JAPANESE INDUSTRIAL STANDARD JIS 2 87 19: 1996 Metamerism index - Evaluation method of degree of metamerism for change in illuminant (nm) 540 October, 2000 ERRATA - Error Correct 0.356 0.359 Page 10, In Attached Table 2-1-2, the values of fi of F6 for each wavelength indicated below shall be correct
2、ed: Page 24, In Attached table 5- 1- 1, the value of fi of C for the wavelength indicated below shall be corrected: I wavelength 1 c, .fi I Remarks: This erratum is for correcting the first edition of this Standard. Japanese Standards Association -9- Copyright Japanese Standards Association Provided
3、 by IHS under license with JSALicensee=IHS Employees/1111111001, User=Gearhard, Marcus Not for Resale, 06/01/2007 02:20:24 MDTNo reproduction or networking permitted without license from IHS -,-,- STD*JIS Z 8719-ENGL L77b = 4733b08 0538355 b74 - J IS JAPANESE I NDUSTRIAL STAN DAR D Translated and Pu
4、blished by Japanese Standards Association Metamerism index-Evaluation method of degree of metamerism for change in illuminant ICs 91. 100. 20 Descriptors : roofing tiles, heavy clay ceramics, clay minerals, tiles Reference number : JIS Z 8719 : 1996 (E) 15 S Copyright Japanese Standards Association
5、Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Gearhard, Marcus Not for Resale, 06/01/2007 02:20:24 MDTNo reproduction or networking permitted without license from IHS -,-,- Z 8719 : 1996 This translation has been made based on the original Japanese Industrial Standard
6、 revised by the Minister of International Trade and Industry through deliberations at Japanese Industrial Standards Committee in accordance with the Industrial Standardization Law: Date of Establishment: 1984-12-01 Date of Revision: 1996-07-01 Date of Public Notice in Official Gazette: 1996-07-01 In
7、vestigated by: Japanese Industrial Standards Committee Divisional Council on Basic Items JIS Z 8719:1996, First English edition published in 1997-06 Translated and published by: Japanese Standards Association 4-1-24, Akasaka, Minato-ku, Tokyo, 107 JAPAN i n the event of any doubts arising as to the
8、contents, the original JIS is to be the final authority. Q JSA 1997 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing fr
9、om the publisher. Printed in Japan Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Gearhard, Marcus Not for Resale, 06/01/2007 02:20:24 MDTNo reproduction or networking permitted without license from IHS -,-,- STD-JIS Z 8719-ENGL
10、 L79b m q933b08 0538157 Lib7 m JAPANESE INDUSTRIAL STANDARD JIS Z 8719:1996 Metamerism index-Evaluation method of degree of metamerism for change in illuminant 1 Scope This Japanese Industrial Standard specifies the evaluation method for degree of metamerism of a pair of samples(1) which the tristim
11、ulus values are in matching or approximately in matching even though the spectral characteristics are different (hereafter referred to as “metameric pair”) under an illuminant which is taken as a reference (hereafter referred to as “reference illuminant”) by degree that the tristimulus values come t
12、o unmatching when the illuminant is changed. Note (1) A pair of samples does not include the sample with light source and fluorescency . Remarks 1 The evaluation method of degree of metamerism for change in illuminant (hereafter referred to as “degree of illuminant metamer- ism”) specified in this S
13、tandard conforms with the evaluation method of degree of metamerism specified in 5.2 of Publication CIE No. 15.2 (1986) Colorimetry, 2nd ed. (hereafter referred to as “CIE No. 15.2”) the Commission International de 1Eclairage-CIE in short-recom- mended in 1986. 2 In addition to the evaluation method
14、 of degree of metamerism specified in this Standard, JIS Z 8718, Evaluation method ofdegree ofmetamer- ism for change in observers specifies the evaluation method of metamer- ism when changing the observer. 3 The following standards are cited in this Standard: JIS Z 8105 JIS Z 8701 JIS Z 8720 JIS Z
15、8722 JIS Z 8724 JIS Z 8725 P JIS Z 8730 Glossary of colour terms Colour specification-The CIE 1931 standard colorimet- ric system and the CIE 1964 supplementary standard colorimetric system Standard ill uminants and sources for colorimetry Methods of colour measurement-Reflecting or transmit- ting o
16、bjects Methods of measurement for light source colour Methods for determining distribution temperature and colour temperature or correlated colour temperature of light sources Colour specification-Colour differences of non-luminous object colours 2 Definitions For the purpose of this Standard, the f
17、ollowing definitions shall apply, and others be in accordance with JIS Z 8105. (1) degree of metamerism A degree of unmatching of tristimulus values of metameric pair under the observing condition different from the reference. (2) degree of illuminant metamerism A degree of metamerism when the illum
18、inant changes. Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Gearhard, Marcus Not for Resale, 06/01/2007 02:20:24 MDTNo reproduction or networking permitted without license from IHS -,-,- 2 Z 8719 : 1996 (3) metamerism index An
19、 index indicating degree of illuminant metamerism of the metameric pair. Remarks : When it is necessary to distinguish, “Illuminant” shall be described before the words “metamerism index”. 3 Reference illuminant and test illuminant 3.1 Reference illuminant For the reference illuminant, the standard
20、illuminant Da specified in JIS Z 8720 shall generally be used. Remarks : In the case where any other illuminant than the standard illuminant De5 is used for the reference illuminant, it shall be selected from the standard illuminants or supplementary standard illuminants specified in JIS Z 8720, and
21、 its type shall be stated clearly. 3.2 Test illuminant The test illuminant shall generally be selected from the stan- dard illuminant A in accordance with JIS Z 8720 or representative fluorescent lamps having relative spectral power distributions specified in Attached Table 1. In the case where any
22、other illuminant is used for the test illuminant its type shall be stated clearly. Remarks : In selecting the test illuminants of Attached Table 1, F6, F8 and F10 given in bold letters shall preferentially be selected. Informative reference : In the Commission International de 1Eclairage (CIE), F2,
23、F7 and F11 marked with * in Attached Table 1 are defined as to be selected preferentially. 4 Evaluation of degree of metamerism The degree of metamerism of metameric pair shall be evaluated by the metamerism index. The metamerism index shall be a colour difference of metameric pair in colour matchin
24、g under the reference illuminant, evaluated under the test illuminant. In the case where the metameric pair under the reference illuminant and the condition of the tristimulus values not in matching perfectly, the colour difference shall be obtained after a correction has been carried out so that it