JIS-B-9925-1997-R2003-ENG.pdf
《JIS-B-9925-1997-R2003-ENG.pdf》由会员分享,可在线阅读,更多相关《JIS-B-9925-1997-R2003-ENG.pdf(13页珍藏版)》请在三一文库上搜索。
1、 STD-JIS B 7725-ENGL l777 P q733bO8 055Lb38 585 P J IS I JAPANESE I N D USTR IAL STANDARD Translated and Published by Japanese Standards Association Light scattering automatic particle counter for liquid ICs 19.120 Descriptors : light, diffusion (waves), particle size measurement, liquids Reference
2、number : JIS B 9925 : 1997 (E) 7s Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/13/2007 07:28:18 MDTNo reproduction or networking permitted without license from IHS -,-,- B 9925 : 1997 Foreword T
3、his translation has been made based on the original Japanese Industrial Standard revised by the Minister of International Trade and Industry through deliberations at Japanese Industrial Standards Committee in accordance with the Industrial Standardization Law. Consequently JIS B 9925:1991 is replace
4、d with JIS B 9925:1997. Date of Establishment: 1991-03-01 Date of Revision: 1997-09-20 Date of Public Notice in Official Gazette: 1997-09-22 Investigated by: Japanese Industrial Standards Committee Divisional Council on General Machinery JIS B 9925 :1997, First English edition published in 1998-10 T
5、ranslated and published by: Japanese Standards Association 4-1-24, Akasaka, Minato-ku, Tokyo, 107-8440 JAPAN In the event of any doubts arising as to the contents, the original JIS is to be the final authority. L O JCA 1998 All rights reserved. Unless otherwise specified, no part of this publication
6、 may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. Printed in Japan Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111
7、001, User=Wing, Bernie Not for Resale, 03/13/2007 07:28:18 MDTNo reproduction or networking permitted without license from IHS -,-,- STD-JIS B 7725-ENGL 2777 m 4733bU U551bllD 133 m JAPANESE INDUSTRIAL STANDARD JIS B 9926: 1997 Light scattering automatic particle counter for liquid 1 Scope This Japa
8、nese Industrial Standard specifies light scattering automatic par- ticle counters for measurement of the size and number of particles in liquids (hereafter referred to as “particle counters” ). Remarks 1 These particle counters are used for counting particulates in liquids such as solvents, chemical
9、 solutions, and highly purified water. 2 The normative references to this Standard are as follows: JIS B 9920 Measuring methods for airborne particles in clean room and evaluating methods for air cleanliness of clean room JIS B 9921 Light scattering automatic particle counter JIS K 0554 Testing meth
10、ods for concentration of fine particles in highly purified water JIS Z 8103 Glossary of terms used in instrumentation JIS Z 8122 Contamination control-Vocabulary JIS Z 8901 Test powders and test particles 2 Definitions For the purpose of this Standard, the definitions specified in JIS B 9921, JIS Z
11、8103, JIS Z 8122 and JIS Z 8901, and the following definitions shall apply: (i) false count The counted value on the counter even though there is no particle within a measurable range in the measured liquid. flow cell A transparent flow passage used for irradiation of light beams to the specimen liq
12、uid. identification limit voltage The threshold voltage of an electronic circuit which selects pulse waves by means of peak voltage values. effective observation area In the flow cell, the area where the particles are to be actually counted. effective specimen flow rate The amount of the specimen li
13、quid passing the effec- tive observation area per unit time. (2) (3) (4) (5) 3 Classification Particle counters are classified into two types of the general type that the volume of the effective observation area does not depend on the particle size and the monitor type that depends thereon. 4 Princi
14、ple of measurement The sample liquid is introduced at a given flow rate into the flow cell from the specimen introducing inlet of the particle counter and then passed through the region irradiated by light beams. The light scattered by individual particle Copyright Japanese Standards Association Pro
15、vided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/13/2007 07:28:18 MDTNo reproduction or networking permitted without license from IHS -,-,- STD-JIS B 9925-ENGL 1997 m 4933b08 0551b4L 07T m Light source unit 2 B 9925 : 1997 Irradiation Scatter
16、ed light Photoelec- Pulse- height selecting system system - optical - Flow cell - receiving optical - - unit i t unit is converted to a pulse-form electric signal by a photoelectric element such as a photo- multiplier and the number of passing particles are obtained by counting the number of the pul
17、se-form signal obtained. In the general type particle counter, in order that a certain relation is made up be- tween the peak value of the pulse-form signal and the particle size, only the scattered light from the particles passing the irradiation area, where the strength of irradiated light is cons
18、idered to be approximately uniform is detected. The pulse-form signal is selected by comparing the peak value of the pulse-form signal with the identification limit voltage corresponding to the particle size and the number of particles at each divi- sion of particle size is obtained by counting the
19、number of particles of the selected pulse-form signal. The monitor type particle counter which is not composed in such a form that a cer- tain relation is made up between the peak value of the pulse-form signal and the parti- cle size is possible to give an approximately correct particle size distri
20、bution by setting up some kinds of identification limit to select the pulse-form signal, when the shape of the particle size distribution of the specimen particles is within a range assumed in advance. 5 Constitution An particle counter consists of a light source unit, irradiation optical system, li
21、quid-introducing system(), flow cell, optical system for receiving the scattered light, photoelectric conversion unit and pulse-height selecting unit. In addition to the above, where required, the counter is equipped with output terminals for particle pulse signals from the photoelectric conversion
22、unit and input terminals for false pulse sig- nals to the pulse-height selecting unit. An example of the constitution is shown in Fig.1. I I Note () Types of liquid introducing systems include the compression type using air pressure, the suction type which draws liquids by means of a cylinder or the
23、 like, and the self-flowing type which introduces liquids from the distribution pipe by utilizing the pressure in the pipe. Fig. 1 Example of constitution of light scattering automatic particle counter 6 Specification and performance 6.1 Specification 6.1.1 Indication of measured quantity The result
24、 of measurement shall be indicated with the concentration of particles of the specific particle size or larger or within a range Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/13/2007 07:28:18 MDT