JIS-K-0089-1998-R2008-ENG.pdf
《JIS-K-0089-1998-R2008-ENG.pdf》由会员分享,可在线阅读,更多相关《JIS-K-0089-1998-R2008-ENG.pdf(13页珍藏版)》请在三一文库上搜索。
1、STD-JIS K 0087-ENGL 1998 W 4933b08 0553793 58b E JIS JAPAN ESE I NDUSTRIAL STANDARD Translated and Published by Japanese Standards Association JIS K 0089:1g98 Methods for determination of acrolein in flue gas c L i ICs 13.040.40; 71.040.40 Descriptors : benzene, exhaust gases, gas analysis, aldehyde
2、s (aliphatic), industrial air pollutants, industrial wastes, sampling methods, spectrophotometry, gas chromatography, determination of content Reference number : JIS K 0089 : 1998 (E) 7s Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001,
3、 User=Japan, IHS Not for Resale, 02/16/2008 02:21:13 MSTNo reproduction or networking permitted without license from IHS -,-,- K 0089 : 1998 Foreword This translation has been made based on the original Japanese Industrial Standard revised by the Minister of International Trade and Industry through
4、deliberations at Japanese Industrial Standards Committee in accordance with the Industrial Standardization Law: Date of Establishment: 1975-08-01 Date of Revision: 1998-03-20 Date of Public Notice in Official Gazette: 1998-03-20 Investigated by: Japanese Industrial Standards Committee Divisional Cou
5、ncil on Environment Technical Committee on Air Quality JIS K 0089:1998, First English edition published in 1998-10 Translated and published by: Japanese Standards Association 4-1-24, Akasaka, Minato-ku, Tokyo, 107-8440 JAPAN b In the event of any doubts arising as to the contents, the original JIS i
6、s to be the final authority. O JSA 1998 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. Printed in
7、 Japan Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Japan, IHS Not for Resale, 02/16/2008 02:21:13 MSTNo reproduction or networking permitted without license from IHS -,-,- JAPANESE INDUSTRIAL STANDARD JIS K 0089 : 1998 Method
8、s for determination of acrolein in flue gas 1 Scope This Japanese Industrial Standard specifies methods for determination of acrolein (acrylaldehyde) in flue gas. Remarks i In this Standard, flue gas means ones which are generated by being ac- companied with works for production or use of acrolein i
9、n the manufac- turing processes of various chemicals and exhausted out to flue, chim- ney or duct. 2 The normative references to this Standard are shown in Attached Ta- ble l. 2 Common items The common items concerned with chemical analysis, sampling method of flue gas, gas chromatographic analysis
10、and molecular absorptiometric analy- sis shall be in accordance with JIS K 0050, JIS K 0095, JIS K 0114 and JIS K 0116 respectively. 3 methods and their outlines shall be as shown in Table 1. Classification of analytical methods and their outlines Classification of analytical Table 1 Classification
11、of analytical methods and their outlines Classifica- tion of analytical methods Gas chro- matogra- PhY Hexylre- sorcinol absorpti- ometry Outline of analytical method Summary Collect the sample gas in a vacuum collecting bottle, condense at low tempera- ture or as it is and inject the gas into the g
12、as chro- matograph with hydrogen flame ionization detector. Determine acrolein with chromatogram obtained. After absorbing acrolein in flue gas into a absorption solution, develop the col- our by heating and meas- ure the absorbance (605 nm) of this solution. Sampling Vacuum collecting bottle method
13、 Absorption bottle method Absorption solution : Mixed solution of trichloroacetic acid, mercury ( II ) chloride and 4-hexylresorcinol Volume : 50 ml Range of deter- mination (PPd 0.01 ppm to 1 O00 PPm (For i 1 of sam- pling gas) 5 to 2 O00 (For 20 1 of sampling gas) Applica- tion re- quirement In ac
14、cor- dance with 6 . 2 . 1 4 Gas sampling method Gas sampling method shall be as follows. Sample gas shall be collected at least two times as a rule in a same position within adjacent times and analyzed respectively . Copyright Japanese Standards Association Provided by IHS under license with JSALice
15、nsee=IHS Employees/1111111001, User=Japan, IHS Not for Resale, 02/16/2008 02:21:13 MSTNo reproduction or networking permitted without license from IHS -,-,- STDoJIS K 0089-ENGL 1998 Li933b08 0553794 295 2 K 0089 : 1998 4.1 Sampling position of gas for analysis shall be selected the point where the t
16、ypical gas is collected, for example the point where the flow rate of gas does not remarkably change. Sampling position os gas 4.2 Classification of sampling methods There are two types of method. One is for 1 1 or under (vacuum collecting bottle method) and the other for approx. 20 1 (absorption bo
17、ttle method). 4.3 When sampling gas volume is 1 1 or under This method shall be applied for the gas chromatography. 4.3.1 Vacuum collecting bottle The vacuum collecting bottle, as shown in Fig. 4 (b-2) of JIS K 0095, which is 1 I of inner capacity with a fluoride resin valve requiring no grease and
18、with a silicone rubber plug (l). Note (l) The inside of the bottle shall be washed previously with a detergent. When low temperature concentration method is employed, inner volume of the bottle shall be measured. 4.3.2 Sampling of gas Before sampling of the gas, air in the vacuum collecting bottle s
19、hall be evacuated. When sampling of gas is carried out, open the valves of the bottle and introduce the sample gas from the gas sampling tube (Approx. 2 mm to 3 mm inner diameter ) through a dehumidification tube (). Note (9 Temperatures of atmosphere and flue gas shall be measured prelimi- narily.
20、Those data can be used when the correction is required. Except where the flue gas temperature is remarkably high, atmospheric tem- perature may use as the temperature of sample gas at the time of Sam- pling. 4.4 When sampling gas volume is approx. 20 1 Hexylresorcinol absorptiometry. This method sha
21、ll be applied for the 4.4.1 Reagents and preparation of reagent solution (1) Reagents (a) Water A2 grade specified in J l S K 0557. (b) Ethanol specified in JlS K 8102. (c) 4-hexylresorcinol (melting point 68 “c to 70 “c) (d) Mercury (II) chloride specified in JlS K 8139. (e) Trichloroacetic acid sp
22、ecitied in JlS K 8667. (2) Preparation of absorption stack solution Preparation of stock solution for absorp- tion shall be as follows. Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Japan, IHS Not for Resale, 02/16/2008 02:21:1
23、3 MSTNo reproduction or networking permitted without license from IHS -,-,- STDOJIS K 0087-ENGL 1978 W 4933b08 0.553795 121 W 3 K 0089 : 1998 (a) 4-hexylresorcinol solution After dissolving 5 g of 4-hexylresorcinol (melting point 68 “C to 70 O C ) in 5 ml of ethanol, dilute to 10 ml with ethanol. (b
24、) Mercury ( II ) chloride solution Dissolve 3 g of mercury ( II ) chloride of guaranteed grade in ethanol and dilute to 100 ml with ethanol. (c) Trichloroacetic acid saturated solution Add 10 ml of water to 100 g of trichloro- acetic acid, and dissolve by heating on a water bath ( 3 ) (). Notes (3)
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JIS 0089 1998 R2008 ENG