JIS-R-7231-1971-ENG.pdf
《JIS-R-7231-1971-ENG.pdf》由会员分享,可在线阅读,更多相关《JIS-R-7231-1971-ENG.pdf(11页珍藏版)》请在三一文库上搜索。
1、JIS R*7231 71 W 4933b08 00701bb I9 I- l UDC 661.666-404.9: 620.1: 621.365.036.61 JAPANESE INDUSTRIAL STANDARD Testing Method for Solderberg Paste JIS R 723 1 - 1 9 7 1 Translated and Published by Japanese Standards Association 5 E P - 4 Printed in Japan 7s (.+ Copyright Japanese Standards Associatio
2、n Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/12/2007 08:54:16 MDTNo reproduction or networking permitted without license from IHS -,-,- J I S R*7231 71 4933608 0070167 3 0 a- l Translation without guarantee In the event of any doubt
3、arising, the original standard in Japanese is to be evidence R 7231-1971 Japanese Text Established by Minister of International Trade and Industry Date of Establishment: September 1, 1964 Date of Revision: July 1, 1972 Investigated by: Japanese Industrial Standards Committee Technical Committee on S
4、olderberg Paste (Chairman: YAMAUCHI Shunkichi) Divisional Council on Ceramics (Chairman: YOSHIKI Bumpei) This English translation is published by: Japanese Standards Association 1-24, Akasaka 4, Minato-ku, I Tokyo 107 Japan 1975 0 Copyright Japanese Standards Association Provided by IHS under licens
5、e with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/12/2007 08:54:16 MDTNo reproduction or networking permitted without license from IHS -,-,- J I S R*7231 7 1 4933bOA 00701bA 5 UDC 661.666-404.9:620.1:621.365.036.61 JAPANESE INDUSTRIAL STANDARD Testing Method for Solde
6、rberg Paste J I S R 7231-1971 I . Scope This Japanese Industrial Standard specifies testing method for solderberg paste, hereinafter referred to as the “pastell. aluminium electrolysis. Provided that, exclusive of the paste used for 2. Test Item 2. I 2.2 Physical Testing Method Softening point Chemi
7、cal Testing Method Ash content, moisture content, volatile matter 3 , Sampling Method 3.1 Lot Size One lot size shall be 10 to 15t. quantity is less than I Ot, the total quantity shall be made as one lot. Provided that, in case of total 3.2 Sampling from Lot 4 increments shall be sampled at random f
8、rom one lot. The size of one increment shall be about Ikg. 4. Sample Preparation Method Increments sampled in accordance with 3 shall be collected from each lot and divided in two, and be made as samples for following chemical testing and physical testing. 4.1 Sample Preparation Method for Chemical
9、Testing 4. I .I CrushingdReduction Sample for chemical testing shall be crushed to 15mm o r less, and then crushed to 5mm or less on the rubbing board. The crushed sample shall be made reduction to about lkg by the use of riffle sampler, and further, after crushed to 2mm o r less, shall be divided i
10、nto two samples of about 500g each. 4. I ,2 Sample for Analysis One of samples obtained in 4. I .I shall be crushed so as to pass the 2000 p sieve, mixed thoroughly and allotted to the sample for moisture content measurement, and the other one shall be after made reduction to about 125g by the use o
11、f riffle sampler, crushed to 0,5mm o r less, and further, shall be made reduction by riffle sampler, mixed thoroughly and allotted to the sample for analysis of volatile matter and ash content. 4.2 SamiJle Preparation Method for Physical Testing 4.2.1 CrushingqReduction Sample for physical testing s
12、hall be crushed with caution to about 25mm o r less, not to break the blending particles as far as possible, and shall be made reduction to about 500g by means of conical quartering. Applicable Standards: JIS K 2275-Method of Test for Water in Crude Oil and Petroleum Products (Distillation Method) J
13、IS K 2422-Methods for Testing Tar Acids JIS K 2432-Xylene (Xylole) JIS K 2433-Solvent Naphtha JIS M 881 2-Method for Ultimate Analysis of Coal and Coke Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale,
14、03/12/2007 08:54:16 MDTNo reproduction or networking permitted without license from IHS -,-,- - . J I S R*7231 7 1 m 4933b08 00701b 7 m 2 R 7231-1971 4.2.2 Forming of Sample Shall conform to as follows. (I) Sample prepared in 4.2. I shall be put in the steel sheet vessel of length 160mm, width 125mm
15、, depth 50mm. (2) The dryer (Appendix I) specified in 2.2(2) of JIS M8812-Method for Ultimate Analysois of Coal and Coke, shall be set previously at the temperature within 100 to 140 C which is suitable for forming, the vessel of (1) containing the sample shall be put in it, and shall be softened th
16、e sample by heating. Moreover, the heating temperature shall be clarified on the report, After softened the sample, take out the vessel containing sample, mingle thoroughly and then weigh about 65g quickly, insert it into metallic mold heated previously at 90 to 100C, and shall make forming of diame
17、ter 25mm, iength about 80mm by loading about 5Okg with a push rod, After cooling, take it out from the metallic mold, and shall be made as the sample of softening point test. Samples shall be formed 3 pieces (Attached Fig. I ) . (3) 5. Chemical Testing Method 5.1 Estimation Method of Ash Content O 5
18、. I . I Summary Sample shall be incinerated by heating at 800 C in air, and shall be made as ash content by the percentage of quantity of residual ash against the sample, 5. I . 2 Apparatus Shall conform to 3.2 of JIS M 881 2-Method for Ultimate Analysis of Coal and Coke, 5. I .3 Operation Operation
19、 shall conform to the following methods. Weigh accurately about Ig of sample into the incineration vessel previously set as constant weight, and spread thinly. (I) (2) Put the incineration vessel into previously measured isothermal zone of electric furnace set at room temperature, (3) Slightly open
20、the door of the electric furnace and pass the current to furnace, raise the temperature to 5OO0C in about 60 minutes, after that, raise to 8OO0C in 30 to 60 minutes and keep at 800 5 10C. Generally, the keeping time may be one hour, but in case when the incineration is considered as difficult it sha
21、ll be 2 to 3 hours. The incineration vessel shall be taken out when the incineration is finished, and shall be cooled, at first on cold metallic plate for 1 O minutes, and then in the desiccator for 15 to 20 minutes. (4) (5) After cooled immediately the quantity of ash shall be obtained by weighing.
22、 5, I , 4 Calculation be rounded off to the second figure. Ash content shall be obtained by the following formula and shall W cl=- x 100 where, o: ash content (%) s: weight of sample (g) zu: weight of quantity of ash (g) 5.1 ,5 Frequency of Analysis This operation shall be repeated two times in the
23、same analysis room, Moreover, it may be carried out in different electric furnaces at the same time but must not be carried out in the same electric furnace at the same time. In case when the difference between two measured values exceeds the tolerance(l), the opexation shall be made a new start. Co
24、pyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/12/2007 08:54:16 MDTNo reproduction or networking permitted without license from IHS -,-,- J I S R*7231 71 m 4933608 0070l170 3 m Ash content % 3 R 723