SDI-108-2004.pdf
《SDI-108-2004.pdf》由会员分享,可在线阅读,更多相关《SDI-108-2004.pdf(4页珍藏版)》请在三一文库上搜索。
1、TECHNICAL DATA SERIES S D I STEEL DOOR INSTITUTE 30200 DETROIT ROAD CLEVELAND, OHIO 44145 STEEL DOOR INSTITUTE 2004 Steel Door Institute 108 - 04 Recommended Selection and Usage Guide for Standard Steel Doors SDI-108 Recommended Selection and Usage Guide for Standard Steel Doors Purpose To establish
2、 guide criteria for the selection and usage of 1-34“ and 1-38“ standard steel doors. Selection Standard steel doors are classified in four lev- els: Level 1 1-34“ and 1-38“ standard duty, Level 2 1-34“ heavy duty, Level 3 1-34“ extra heavy duty and Level 4 1-34“ maximum duty. Each of the four levels
3、 noted above offer a range of construction models and designs to meet archi- tectural requirements for preference and appearance. The standard steel door construction models are full flush, seamless and, stile and rail. Recommended minimum gauge requirements for the various levels and models of stan
4、dard steel doors are indicated in table 1. Usage Selection of standard steel doors for general usage is made by analyzing criteria such as frequency of use, including subjection to and degree of possible abuse. Other criteria to be considered in door selec- tion are: conformance to local building co
5、des and fire code regulations; sound attenuation and/or insulation requirements; and architectural design and appear- ance. Table 2 is a reference aid matching standard duty, heavy duty, extra heavy duty and maximum duty doors with general usage requirements within the classification of buildings. W
6、here optional door lev- els and models are indicated, further analysis on an individual job basis is recommended. When unusual or special door usage conditions are encountered, contact a representative member of the Steel Door Institute for consultation and guidance. Table 1 Standard steel door grad
7、es and models LevelModel Full Flush or Seamless Construction MSG No.IP inSI mm 1 Standard Duty 1 200.0320.8 Full Flush 2Seamless 2 Heavy Duty 1 180.0421 Full Flush 2Seamless 3 Extra Heavy Duty 1 160.0531.3 Full Flush 2Seamless 3*Stile flush panels, when specified, are 18 gauge. For complete standard
8、 steel door construction specifications and available sizes, refer to Steel Door Institute Technical Data Series, ANSI A250.8-03 (SDI-100), “Recommended Specifications for Standard Steel Doors and Frames” and ANSI A250.4-01 “Test Procedure and Acceptance Criteria for Physical Endurance for Steel Doo
9、rs, Frames, Frame Anchors and Hardware Reinforcings.” Table 2 Suggested door levels and applications Building Types Standard Steel Door LevelsDoor Design Nomenclature Level 1 Standard Duty Level 2 Heavy Duty Level 3 Extra Heavy Duty Level 4 Maximum Duty 1-38“1-34“ only1-34“ only1-34“ only FGVFGNL Ap
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SDI 108 2004
链接地址:https://www.31doc.com/p-3794083.html