《SDI-111-2000.pdf》由会员分享,可在线阅读,更多相关《SDI-111-2000.pdf(20页珍藏版)》请在三一文库上搜索。
1、TECHNICAL DATA SERIES S D I STEEL DOOR INSTITUTE 30200 DETROIT ROAD CLEVELAND, OHIO 44145 STEEL DOOR INSTITUTE 2004 Steel Door Institute 111 - 00 Recommended Selection and Usage Guide for Standard Steel Doors, Frames and Accessories A. Recommended Standard Steel Door Frame Details B. Recommended Sta
2、ndard Details for Dutch Doors C. Recommended Louver Details for Standard Steel Doors D. Recommended Door, Frame and Hardware Schedule for Standard Steel Doors and Frames E. Recommended Guidelines for the Use of Gasketing and Thresh- olds for Standard Steel Doors and Frames F. Recommended Existing Wa
3、ll Anchors for Standard Steel Doors and Frames G. Recommended Standard Preparation for Double Type (Interconnected) Locks on Standard Steel Doors and Frames H. High Frequency Hinge Preparations for Frames A.Recommended Standard Steel Door Frame Details B.Recommended Standard Details for Dutch Doors
4、C.Recommended Louver Details for Standard Steel Doors D.Recommended Door, Frame and Hardware Schedule for Standard Steel Doors and Frames E.Recommended Guidelines for the Use of Gasketing and Thresholds for Standard Steel Doors and Frames F.Recommended Existing Wall Anchors for Standard Steel Doors
5、and Frames G.Recommended Standard Preparation for Double Type (In- terconnected) Locks on Standard Steel Doors and Frames H.High Frequency Hinge Preparations for Frames The information that follows represents the Standard Steel Door and Frame Industrys considered views on a number of details normall
6、y encountered in building plans and speci- fications. The SDI recommends that they be followed except when very unusual details necessitate special drawings. The enclosed may be used as a reference document or added directly to the job drawings. SDI-111 TECHNICAL DATA SERIES Recommended Standard Ste
7、el Door Frame Details S D I STEEL DOOR INSTITUTE 30200 DETROIT ROAD - CLEVELAND, OHIO 44145 111-A 4“ Block with 1/2“ Plaster Minimum 1/4“ (9.5mm) Maximum 3/4“ (19.0mm) Minimum 1/4“ (9.5mm) Maximum 3/4“ (19.0mm) Throat Opening 2“ (50.8mm) Dimension “A” Jamb Depth Double Rabbet Frame Face Cased Openin
8、g Backbend Soffit Rabbet Stop Single Rabbet Frame Double Rabbet Backbend Return Single Rabbet Slip-On Drywall Frame Knocked Down (Butted) May be Horizontal or Vertical Handing Chart Inside KS RHRB KS R.H. Outside KS Inside Outside LHRB L.H. KS Inside KS LHRB ACTIVE KS L.H. ACTIVE Outside Inside Outs
9、ide KS RHRB ACTIVE KS R.H. ACTIVE KS Indicates Keyed Side of Lockset Knocked Down (Mitered) Set Up Spot Welded Set Up Arc Welded and Ground Smooth Slip on drywall (frame is installed after the wall has been erected). Corner may be screwed together; snap locked, or a slip fit design. Butted Masonry,
10、Brick Tile or Concrete Block4“ Block and Brick Combination Stucco 2 x 4 Wood Stud with 3/4“ Gypsum Board & Plaster 3-1/4“ Steel Stud with 3/4“ Plaster on Metal Lath 3“ (76.2 mm) Precast Gypsum Tile with 5/8“ (15.8 mm) Plaster 1“ Gypsum Core with 5/8“ Gypsum Board with 1/2“ or 5/8“ Gypsum Board 1-5/8
11、“ Steel or Wood Stud with 1/2“ or 5/8“ Gypsum Board 2-1/2“ or 3-5/8“ Steel Stud with Two Layers of 5/8“ Gypsum Board Each Side 2-1/2“ or 3-5/8“ Steel or Wood Stud with 1/2“ or 5/8“ Gypsum Board Existing Masonry or Concrete 2 x 4 Wood Stud with 3/4“ Plaster on Metal Lath 2 x 4 Wood Stud with 3/4“ Pla
12、ster on Metal Lath 2“ Corner Tile and 4“ Block Combination STANDARD FRAME DETAILS Standard Profiles Hardware Locations Corners COMMON WALL CONDITIONS Drywall Note: Center Hinge Omitted on 6-8“ (2032mm), 1-3/8“ (34.5mm) Doors, Unless Specified. Center-Line Hinges Center-Line Lock Strike & Panic Exit
13、Device Strike Center-Line Deadlock Strike Up to 11-3/4“ (298.4 mm) Door Opening Height Equal Equal 40-5/16“ (1023.9mm) 48“ (1219mm) Up to 13“ (330.2mm) Door Opening Width Continuous Arc Weld Inside or Outside Mitered and Arc Welded Door Thk.Dim. “A” 1-3/8“ (38.9mm)1-9/16“ (39.6mm) 1-3/4“ (44.4mm)1-1
14、5/16“ (49.2mm) 2“ Solid Plaster with 1/2“ Gypsum Board Core Butted Masonry, Tile or Concrete Block 3-1/4“ Wire Steel Stud with 3/4“ Plaster on Metal Lath Rubber SilencersGasket Frame Surface Mounted Weatherstrip Surface Applied Pressure Sensitive Weatherstrip Masonry Wire AnchorWood Stud AnchorSteel
15、 Stud AnchorExisting Wall Anchor Adjustable Base AnchorWood Stud Base AnchorTypical Mullion Sections with Base Anchor Hospital Stop Mortise HingeStrike Surface Hardware Reinforcement. Weld-in Reinforcement Shown, Loose Reinforcing Sleeve Available for Field Installation. SPECIAL FRAME CONSTRUCTION D
16、ETAILS AND TYPICAL HARDWARE PREPARATIONS Anchor Details Special Frame DetailsHardware Preparations Masonry Tee Anchor Plaster Partition Anchor (Ceiling Strut Optional) AMWELD BUILDING PRODUCTS INC. P.O. Box 267 Garrettsville, OH 44231 (330) 527-4385 FAX (330) 527-4510 BENCHMARK COMMERCIAL DOORS Divi
17、sion of General Products Co., Inc. P.O. Box 7387 Fredericksburg, VA 22404-7387 (540) 898-5800 FAX (540) 898-5894 CECO DOOR PRODUCTS A United Dominion Company 750 Old Hickory Boulevard One Brentwood Commons, Suite 150 Brentwood, TN 37027-4502 (615) 661-5030 FAX (615) 370-5299 For more information on
18、steel doors and frames, contact any of the following members of the Steel Door Institute: CURRIES COMPANY P.O. Box 1648 Mason City, IA 50402-1648 (641) 423-1334 FAX (641) 423-9104 DEANSTEEL MANUFACTURING CO. 111 Merchant Street San Antonio, TX 78204-1496 (210) 226-8271 FAX (210) 226-0913 THE KEWANEE
19、 CORPORATION P.O. Box 309 Kewanee, IL 61443-0309 (309) 853-4481 FAX (309) 853-5466 MESKER DOOR, INC. 3440 Stanwood Boulevard Huntsville, AL 35811-9021 (256) 851-6670 FAX (888) 851-7896 PIONEER INDUSTRIES INC. 401 Washington Avenue Carlstadt, NJ 07072 (201) 933-1900 FAX (201) 933-9580 REPUBLIC BUILDE
20、RS PRODUCTS 155 Republic Drive McKenzie, TN 38201-0580 (901) 352-3383 FAX (901) 352-3001 SECURITY METAL PRODUCTS CORP. 5700 Hannum Avenue Suite 250 Culver City, CA 90230 (310) 641-6690 FAX (310) 641-6601 STEELCRAFT IR Security & Safety 9017 Blue Ash Road Cincinnati, OH 45242 (513) 745-6400 FAX (513)
21、 745-6446 S T E E L D O O R I N S T I T U T E 30200 DETROIT ROAD CLEVELAND, OHIO 44145 440/899-0010 fax 440/892-1404 www.steeldoor.org TECHNICAL DATA SERIES S D I STEEL DOOR INSTITUTE 30200 DETROIT ROAD - CLEVELAND, OHIO 44145 111-B Recommended Standard Details for Dutch Doors 3/4“ Max. (19mm) Optio
22、nal steel shelf Fasten w/ S.M.S. in field * 39“ Min. (991mm) * 28 1/2“ Min. (724mm) CLStrike Flush steel door “A” “A” Mortise or surface dutch door bolt Lock set ELEVATION NON-FIRE RATED PLAN SECTION “A” - “A” Shelf may be field installed either side 6-8“ (2032mm), 7-0“ (2134mm), 7-2“ (2184mm), 7-10
23、“ (2388mm) & 8-0“ (2438mm) Steel door frame 1 3/4“ (44mm) Flush steel door 10“ Max. (254mm) Finished floor 5 1/2“ Max. (140mm) 5 1/2“ Max. (140mm) Steel bracket * 39“ Min. (991mm) Steel Shelf (optional) *Location is generally 40“ by may vary as indicated by specifier to suit local accessibility code
24、s. Single point latches Shelf (optional) Flat astragalFlat astragal Top door latches into top of bottom door Bottom door latches into frame strike jamb ELEVATION FIRE RATED ELEVATION FIRE RATED Shelf (optional) 30200 DETROIT ROAD CLEVELAND, OHIO 44145 440/899-0010 FAX 440/892-1404 www.steeldoor.org
25、STEEL DOOR INSTITUTE AMWELD BUILDING PRODUCTS INC. P.O. Box 267 Garrettsville, OH 44231 (330) 527-4385 FAX (330) 527-4510 BENCHMARK COMMERCIAL DOORS Division of General Products Co., Inc. P.O. Box 7387 Fredericksburg, VA 22404 (540) 898-5800 FAX (540) 898-5894 CECO DOOR PRODUCTS A United Dominion Co
26、mpany 750 Old Hickory Boulevard One Brentwood Commons, Suite 150 Brentwood, TN 37027 (615) 661-5030 FAX (615) 370-5299 For more information on steel doors and frames, contact any of the following members of the Steel Door Institute CURRIES COMPANY P.O. Box 1648 525 9th Street, SE Mason City, IA 5040
27、1 (641) 423-1334 FAX (641) 423-9104 DEANSTEEL MANUFACTURING CO. 111 Merchant Street San Antonio, TX 78204-1496 (210) 226-8271 FAX (210) 226-0913 THE KEWANEE CORPORATION P.O. Box 309 Kewanee, IL 61443 (309) 853-4481 FAX (309) 853-5466 MESKER DOOR, INC. 3440 Stanwood Boulevard Huntsville, AL 35811 (25
28、6) 851-6670 FAX (888) 851-7896 PIONEER INDUSTRIES INC. 401 Washington Avenue Carlstadt, NJ 07072 (201) 933-1900 FAX (201) 933-9580 REPUBLIC BUILDERS PRODUCTS 155 Republic Drive McKenzie, TN 38201-0580 (901) 352-3383 FAX (901) 352-3001 SECURITY METAL PRODUCTS CORP. 5700 Hannum Avenue Suite 250 Culver
29、 City, CA 90230 (310) 641-6690 FAX (310) 641-6601 STEELCRAFT IR Security & Safety 9017 Blue Ash Road Cincinnati, OH 45242 (513) 745-6400 FAX (513) 745-6446 TECHNICAL DATA SERIES S D I STEEL DOOR INSTITUTE 30200 DETROIT ROAD - CLEVELAND, OHIO 44145 111-C Recommended Louver Details for Standard Steel
30、Doors SDI 111-C Recommended Louver Details for Standard Steel Doors Function Louvers permit free air passage, controlling the volume by their size or design. They diffuse or con- trol direction of air flow by blade design. Insert louvers Louvers commonly used in standard steel doors are of the “inse
31、rt” type designed to be mounted into a cutout in the door and an overlapping frame. In- verted “V” blade, “Z” blade, inverted “Y” or chevron-type blade, lightproof, adjustable blade, grille type, and fus- ible link self-closing fire door type are available in a wide range of sizes. Also available fr
32、om some steel door manu- facturers is a pierced louver design. Insert louvers in- tended for exterior doors or other doors where security is a consideration should have fasteners or materials speci- fied accordingly. Note: If a louver door is required to provide security, the steel door manufacturer
33、 should be consulted. Bird or insect screens are available with many of the standard design louvers. Where specified, consult steel door manufacturer for availability. Weatherproof louvers True weatherproof designs do not exist. Some louvers are manufactured to provide a certain degree of rain prote
34、ction. Louver construction Standard louver frames are a minimum 20 gauge steel with louver blades of a mini- mum 24 gauge steel. The louver blades can be welded or tenoned to the frame and the entire assembly is gen- erally fastened to the door with moldings. Generally, one molding will be an integr
35、al part of the louver, while the other molding will be detachable. When louvers are in- stalled, the detachable moldings should be located on the room or non-security side of the door. Application: Inverted “V” blade and “Z” blade types allow maximum free air flow with minimum static pressure differ
36、ential. Inverted “Y” or chevron blade louver, while offering less free air space, offers a higher strength factor for schools and other areas where vandalism or hard usage may oc- cur. Lightproof louvers are used where light transmission must be avoided. These provide a minimal free air flow. Adjust
37、able blade louvers are used where air flow is var- ied in velocity and control of flow must be provided. Grille type louvers are normally associated with air con- ditioning, where air must be diffused in random flow, avoid- ing higher velocity air flow patterns. Fusible link louvers are used in fire
38、 doors where flames and intense heat passage must be controlled. The link release temperature recommended is 135F (57C). These louvers must be labeled and may not exceed 24“ x 24“. Fusible link louvers are allowed only at the bot- tom of fire doors. Since closing is heat activated, these louvers are
39、 not to be used on smoke control doors. Pierced louvers, available from some steel door manu- facturers, offer a flush condition and may be furnished with internal insect screens. Louvers are formed by em- bossing the door face sheets. Louver size determinations As a guide, the following approximate
40、 percentages of lou- ver size may be used to determine the free area in a given size louver: Pierced louver20% Inverted “V” inserted louver50 60% Inverted “Y” (chevron) inserted louver40 60% “Z” type inserted louver40 45% Adjustable inserted louver40 50% Lightproof inserted louver20% Fusible link in
41、serted louver45% The above percentages assume there is no air pressure drop from one side of the door to the other. On air condi- tion grilles an air pressure drop is normal. An average 70% of the grille size can be used in computing free area on doors with air condition grilles. The percentages not
42、ed above are approximates. Con- sult the individual manufacturers literature for the spe- cific sizes and ratings normal to their program. A combination of glass lites and louvers is common in steel door work. Care should be taken to avoid specify- ing too long a narrow lite when a louver or grille
43、occurs in the bottom of the same unit. In addition, handicap codes may dictate the location of the louver relative to the bot- tom of the door. Standard steel doors can be provided with a variety of louver designs and sizes. This publication contains explanations and details of louver designs that a
44、re most commonly available within the standard door industry. When specified, doors shall be provided with louvers at the bottom and/or top. The choice of which to use must be determined by the architect on aesthetic, functional, and economic grounds. Inverted “V” BladeInverted “Y” BladeChevron or H
45、ood-Type Blade Lightproof“Z” BladeGrille Operating lever Fusible Link Insect screen (optional) Pierced Cross Section Details Full louver doors A minimum 5“ (127.0mm) rail occurs at the top and at the vertical edge of this type unit, a 8“ (203.2mm) minimum rail occurs at the bottom. The percentages n
46、oted above on inserted louvers also apply to this type of door. Pierced louvers are not available on full louvered doors. Consult with door manufacturer for exact stile/rail dimensions. Finish The finish is to be prime painted, except when the louver is used in a factory prefinished door, in which c
47、ase the louver will be finish painted with a color to match the door. For exterior doors, zinc coated louvers are available where specified. The purpose of this publication is to establish a guide for architects and those responsible for scheduling doors, frames, and hardware requirements. Although
48、primarily designed for steel doors and frames, this suggested schedule is flexible enough to list total door and frame requirements of a complete job. Items not specifically covered in the schedule may be listed in the “Remarks” and extra columns near the end. TECHNICAL DATA SERIES S D I STEEL DOOR
49、INSTITUTE 30200 DETROIT ROAD - CLEVELAND, OHIO 44145 111-D Recommended Door, Frame and Hardware Schedule for Standard Steel Doors and Frames General Notes: (1)If a fire door is required, it is to be designated in the “Label” column of schedule with appropriate hourly rating. Also, note in the “Remarks” col- umn whether door is to have an Underwriters Laboratories (UL) Factory Mutual (FM), or Warnock Hersey (WHI) label. (2)Thresholds, when required, are to be noted in “Hardware” column of schedule. (3)Any special item not listed in schedule