UL-325-BULLETINS-2003.pdf
《UL-325-BULLETINS-2003.pdf》由会员分享,可在线阅读,更多相关《UL-325-BULLETINS-2003.pdf(44页珍藏版)》请在三一文库上搜索。
1、Subject 325 333 Pfingsten Road Northbrook, IL 60062 December 4, 2003 TO: SUBJECT: Industry Advisory Conference of UL for Electric Door and Gate Operators; Standards Technical Panel (STP) for Door, Drapery, Gate, Louver, and Window Subscribers to ULs Standards Service for Other Interested Parties Ope
2、rators and Systems, STP 325; Door, Drapery, Gate, Louver, and Window Operators and Systems; Comments and Substantive Changes Received on the ANSI Canvass of Proposed Requirements for the Fifth Edition of the Standard for Door, Drapery, Gate, Louver, and Window Operators and Systems, 325; SUMMARY OF
3、TOPICS This bulletin proposes the following changes in requirements: I) Revisions to address the risk of injury to persons crawling under a stopped, partially open garage door. COMMENTS DUE: January 2,2004 The attached comment matrix provides the comment dispositions from the canvass of the proposal
4、 bulletin dated June 16, 2003. The ballots were due to the Secretary by September 5, 2003. The matrix contains all of the comments that were received in regards to Topic 2. Where a comment has resulted in a proposed change, the proposal is included in Appendix B. The revised effective date is noted
5、in Appendix C. Questions regarding interpretation of requirements should be directed to the responsible UL Staff. Please see Appendix D of this bulletin regarding designated responsibility for the subject product categories. If you wish to change your vote in light of the dispositions/actions or the
6、 proposed changes, please respond to us in writing by January 2, 2004. If we do not hear from you by this date, your original vote will be maintained. UL has considered the comments received in response to Topic 1 of the June 16, 2003 bulletin, and at the request of the submitter, has decided to wit
7、hdraw the proposals from ANSI consideration. Topic 1 proposed for the addition of definitions for the terms ”control,” ”reset control,” and ”reset input” and Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Res
8、ale, 09/03/2007 01:12:16 MDTNo reproduction or networking permitted without license from IHS -,-,- SUBJECT 325 -2- DECEMBER 4,2003 revision of paragraphs 31 .I .5 and 56.8.4 to clarify the intent with respect to the various types of controls. The proposals, along with the comments received, will be
9、sent back to the original submitter for possible further development. The voting for Topic 2 presently is as follows: 13 affirmative, 10 negatives, 3 abstentions, and 6 unreturned ballots. Once UL has determined that consensus has been achieved regarding the ANSI approval of the proposed revisions t
10、o UL 325 in Topic 2 and the STP concurs with the actions/ dispositions, UL plans to adopt the revised version of UL 325 as an ANSI standard. You have the right to appeal this action on a procedural basis through ULs Appeals Process. If you wish to appeal, please respond by December 26, 2003. Please
11、note only appeals based on procedural issues will be heard, technical issues should be resolved at the consensus body level. Guidelines on how to register an appeal can be obtained at http:/ or by contacting the STP Secretary. UL appreciates the time and effort you have put forth to review this stan
12、dard, and look forward to your continued participation in this UL/ANSI standard activity. UNDERWRITERS LABORATORIES INC. REVIEWED BY: AMY K. WALKER Secretary for STP 325 Project Engineer Standards Department Phone: (847) 664-2023 Fax: (847) 313-2023 E-mail: Amy.K.W http:/ JOE MUSS0 Chair for STP 325
13、 Global Standards Department Phone: (847) 664-2964 Fax: (847) 313-2964 E-mail: Joseph.R.M Copyright O 2003 Underwriters Laboratories Inc. SR: DES bul-20030801 Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Re
14、sale, 09/03/2007 01:12:16 MDTNo reproduction or networking permitted without license from IHS -,-,- SUBJECT 325 -Al- DECEMBER 4,2003 APPENDIX A COMMENT MATRIX The Table below provides the comment dispositions from the Ballot of BSRUL325, Topic 2 of proposal bulletin dated June 16, 2003. The Standard
15、 for Door, Drapery, Gate, Louver, and Window Operators and Systems The rows in the comment resolution matrix can be defined as follows: Commenter Paragraph / Text Reference Comment Suggested Revision By Commenter Response Action/Disposition Name of person who submitted comment. Indicates the specifi
16、c reference for the comment. This comment matrix presents the verbatim text of the comment. The proposed revision corresponding to the comment received. Rationale of the action/disposition after reviewing the comment. The recommended decision to the comment. - -I- - Commenter ParaaraDh / Text Refere
17、nce Comment Suggested Revision By Commenter Response Action/Disposition Commenter Paragraph / Text Reference - Stopped, Partially Open Garage Door John R. Murphy Topic 2 The CPSC staff believes that for inherent entrapment protection systems the standard should require four inches of reversal rather
18、 than the two inches currently specified on the ballot. In the case of soft tissue, it may be possible to compress the tissue over two inches before the inherent system is triggered to recognize an obstruction. A reversal of more than two inches may be necessary to completely free an entrapped perso
19、n. No specific revision provided. The intent of the proposal was for the 2-inch reversal to visually indicate to someone that the door was reversing off of an obstruction and thereby reduce the risk of a panic situation. The STP task group, which included a human factor engineer, fully discussed the
20、 2-inch parameter and consensus was reached that 2 inches would be an adequate reversal distance. In addition, a 2-inch reversal is consistent with what is presently required for gate operators. Disagree with comment. No revision proposed. Larry D. Murphy Table Continued on Next Page Copyright Under
21、writers Laboratories Inc. Provided by IHS under license with ULLicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 09/03/2007 01:12:16 MDTNo reproduction or networking permitted without license from IHS -,-,- SUBJECT 325 Comment Suggested Revision By Commenter Response -A2- Table Co
22、ntinued ParaaraDh 32.2.1 : This paragraph removes the time for an operator to coming up to speed prior to sensing the obstruction. This physical requirement of the system is recognized as the standard allows for 1 foot of travel from the full upmost position prior to the 2 second time limit. We coul
23、d support this change if the time were changed to 3 seconds to allow for the system to achieve its operating condition. There is also no clear definition of what is meant by ”shall initiate reversal of the door.” No specific revision provided. It is ULs understanding that both comments are concerned
24、 with regards to a clearer definition of what constitutes initiation of a reversal. Therefore. UL is DroDosina to clarifv that reversal should DECEMBER 4,2003 Action/Disposition be triggered by thesensing of the bstructioh by the operator. Proposed revision based on comment. (See Topic 1 of Appendix
- 配套讲稿: