UL-609-BULLETINS-2004.pdf
《UL-609-BULLETINS-2004.pdf》由会员分享,可在线阅读,更多相关《UL-609-BULLETINS-2004.pdf(40页珍藏版)》请在三一文库上搜索。
1、Subjects 294 (205, 205A, 365, 603, 606, 609, 634, 636, 639, 681, 827, 864, 985, 1023, 1037, 1076, 1610, 1635, 1637, 1641) (in reply, refer to Subject 294) TO: 1655 Scott Blvd. Santa Clara, CA 95050 July 30, 2004 Standards Technical Panel (STP) for Burglary Protection Systems and Services, STP Standa
2、rds Technical Panel (STP) for Burglary Protection Equipment, STP 205A; Subscribers to ULs Standards Service for 205; Access Control System Units; Police Station Connected Burglar Alarm Units and Systems; Power Supplies for Use with Burglar-Alarm Systems; Linings and Screens for Use with Burglar-Alar
3、m Systems; Local Burglar Alarm Units and Systems; Connectors and Switches for Use with Burglar-Alarm Systems; Holdup Alarm Units and Systems; Intrusion-Detection Units; Installation and Classification of Burglar and Holdup Alarm Systems; Central-Station Alarm Services; Control Units and Accessories
4、for Fire Alarm Systems; Household Fire Warning System Units; Household Burglar-Alarm System Units; Antitheft Alarms and Devices; Proprietary Burglar Alarm Units and Systems; Central-Station Burglar-Alarm Units; Digital Alarm Communicator System Units; Home Health Care Signaling Equipment; Installati
5、on and Classification of Residential Burglar Alarm Systems; Other Interested Parties SUBJECT: Report of the Meeting of the Standards Technical Panels of UL for Burglary Protection Equipment and Burglary Protection Systems and Services; Summary of Topics The following topics were discussed at the mee
6、ting: 1. Comments received regarding the proposal bulletin dated September 29, 2003 2. Comments received regarding the ANSI ballot for UL 1641 dated October IO, 2003 3. Comments received regarding the ANSI ballot for UL 1037 dated March 19, 2004 4. Proposed revision to the Standard for Connectors an
7、d Switches for Use with Burglar- Alarm Systems, UL 634 5. ANSI Recognition update 6. Mechanical Strength Test for Metal Enclosures and Guards Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=Army Northwestern Div./7838506130, User=abc, abcdd Not for Resale, 09/1
8、0/2006 21:15:13 MDTNo reproduction or networking permitted without license from IHS -,-,- SUBJECT 294 -2- JULY 30,2004 7. Dielectric Voltage Withstand Test 8. Transient Test 9. Jarring Test IO. Fail Safe Egress I I . Remote Station Service 12. Request for Working Groups for UL 294 13. Manual backup
9、at subsidiary locations 14. Harmonization with IEC standards 15. False Alarms 16. Enhanced Call Verification 17. Voice Over Internet Protocol (VolP) 18. EMC/EM1 requirements 19. Proposed changes to the Standard for .:cess Con o 20. Signaling across the internet 21. Makeup of STP 205 and STP 205A Sys
10、tem Units, UL 294 22. Consistency of standards covered under STP 205 and STP 205A COMMENTS DUE: September 3,2004 A meeting of the Standards Technical Panels of UL for Burglary Protection Systems and Services, STP 205 and Burglary Protection Equipment, STP 205A was held on June 22 and 23, 2004 at the
11、 Hilton Northbrook. The purpose of the meeting was to discuss comments received on the Subject 1610 bulletin dated September 29, 2003, the STP 205 bulletin dated October IO, 2003 and the STP 205A bulletin dated March 19, 2004. The meeting was also held to discuss several proposals that were received
12、. Comments should be made in writing and may be sent by fax to (408) 556-6045 or by mail to the attention of Jeline Gonzaga at ULs Santa Clara office, 1655 Scott Blvd., Santa Clara, CA 95050. Comments may also be sent via E-mail to Jeline.G. Please reference all correspondence to Subject 294. Note a
13、ll comments received are public and may be circulated to others. If you respond by fax or E-mail, please include your full name and company name and address to ensure a reply. Attached as Appendices A, B, and C for your review and comment are the comment matrices for the proposal bulletins dated Sep
14、tember 29, 2003, October IO, 2003 and March 19, 2004, respectively. Attached as Appendices D - G for your review and comment are proposed requirements for UL 365, UL 1076, UL 1610 and UL 1641 as referenced in the comment matrices. Attached as Appendix H Copyright Underwriters Laboratories Inc. Provi
15、ded by IHS under license with ULLicensee=Army Northwestern Div./7838506130, User=abc, abcdd Not for Resale, 09/10/2006 21:15:13 MDTNo reproduction or networking permitted without license from IHS -,-,- SUBJECT 294 -3- JULY 30,2004 Standard UL 365 UL 609 UL 1023 UL 1076 UL 1610 UL 1635 UL 1641 is inf
16、ormation regarding Working Groups. Attached as Appendix I is a list of those who attended the meeting. Questions regarding interpretation of requirements should be directed to the responsible UL Staff. Yes No Abstain 29 3 O 28 2 O 16 O O 27 3 O 16 1 O 17 1 O 17 1 O The attached comment matrices prov
17、ide the proposed comment dispositions from the ballot of the proposal bulletins dated September 29, 2003, October IO, 2003 and March 19, 2004. The ballots were due to the Project Manager by November 28, 2003, December 9, 2003 and May 18, 2004 respectively. The matrices contain all of the comments th
18、at were received. The effective dates are the same as stated in the proposal bulletins dated September 29, 2003, October IO, 2003 and March 19, 2004 unless noted otherwise. UL has determined that consensus has been achieved regarding the ANSI approval of the proposed revisions to UL 365, UL 609, UL
19、1023, UL 1076, UL 1610, UL 1635 and UL 1641. The initial consensus count is as follows: If you wish to change your vote in light of the dispositions/actions or the proposed changes, please respond to us in writing by September 3, 2004. If we do not hear from you by this date, your original vote will
20、 be maintained. If the STP concurs with the dispositions/actions, UL plans to adopt the revised versions of UL 365, UL 609, UL 1023, UL 1076, UL 1610, UL 1635 and UL 1641 as ANSI standards. Once UL has determined that consensus has been achieved regarding the ANSI approval of UL 1037 and the STP con
21、curs with the actions/dispositions, UL plans to adopt the revised version of UL 1037 as an ANSI standard. The initial consensus count is 10 yes, 1 no, and O abstain. If you wish to change your vote in light of the dispositions/actions or the proposed changes, please respond to us in writing by Septe
22、mber 3, 2004. If we do not hear from you by this date, your original vote will be maintained. Anyone who has submitted an objection has the right to appeal this action on a procedural basis through ULs Appeals Process. If you wish to appeal, please respond by September 3,2004. Please note only appea
23、ls based on a procedural issue will be heard, technical issues should be resolved at the consensus body level. Guidelines on how to register an appeal can be obtained on http:/ ulstandardsinfonet.uI.com or by contacting the STP Project Manager. Please note that proposed requirements are of a tentati
24、ve and early nature and are for review and comment only. Current requirements are to be used to judge a product until these requirements are published in final form. * * * * * * The following report is not intended to be a verbatim transcript of the discussion at the meeting, but is intended to reco