UL-44-BULLETINS-2007.pdf
《UL-44-BULLETINS-2007.pdf》由会员分享,可在线阅读,更多相关《UL-44-BULLETINS-2007.pdf(126页珍藏版)》请在三一文库上搜索。
1、FOR INTERNAL UL OR CSDS USE ONLY NOT FOR OUTSIDE DISTRIBUTION Subject 44 May 4, 2007 SUMMARY OF TOPICS The following changes in requirements are being proposed: 1. For Preliminary Review Only: Major Revisions to UL 44 Based on Publication of UL 2556, and other Revised Construction, Performance, and
2、Marking Requirements Including but not Limited to the Following Signifi cant Changes: Deletion of all Figures, Several Tables, Annex H, and all of the Test Methods, and Extensive Revision of the Test Requirements Section; Deletion of Requirements for Lead-Alloy Conductors; Various Revisions to Marki
3、ng Requirements Including Those for Aluminum Conductors, Clarifi cation of Country-Specifi c Marking Requirements, and Addition of a Marking for Cables not Intended for Outdoor Use; Revision to the Mandrel Diameter and Related Testing Requirements; Reinstatement of Previously Deleted Requirements fo
4、r Thickness of Overall Jacket on Deep Well Pump Cables; Clarifi cation to Several Tables Addressing Various Requirements for Types RW75, RW90, RWU75, and/or RWU90 cables; and Miscellaneous Editorial Wording Revisions COMMENTS DUE: June 18, 2007 This proposal is for review and comment only (no ballot
5、 at this time). Please note that comments on a preliminary review document will not receive a response from the proposal author through CSDS. Instead, the proposal author is asked to review the comments received during the preliminary review and adjust the proposals and/or supporting rationale as th
6、e author determines to be appropriate. The preliminary review process is an informal mechanism that provides authors with the opportunity to refi ne their proposals before the proposals advance in ULs standards development process. Normally, the next step in the process is the more formal STP ballot
7、 and stakeholder review process. Only comments newly posted during the more formal STP ballot and stakeholder review process will be addressed and responded to. For your convenience in review, proposed additions to existing requirements are shown underlined and proposed deletions are shown lined-out
8、. Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 05/15/2007 23:37:37 MDTNo reproduction or networking permitted without license from IHS -,-,- FOR INTERNAL UL OR CSDS USE ONLY NOT FOR OUTSIDE DISTRIBU
9、TION 1. For Preliminary Review Only: Major Revisions to UL44 Based on Publication of UL 2556, and other Revised Construction, Performance, and Marking Requirements Including but not Limited to the Following Signifi cant Changes: Deletion of all Figures, Several Tables, Annex H, and all of the Test M
10、ethods, and Extensive Revision of the Test Requirements Section; Deletion of Requirements for Lead-Alloy Conductors; Various Revisions to Marking Requirements Including Those for Aluminum Conductors, Clarifi cation of Country-Specifi c Marking Requirements, and Addition of a Marking for Cables not I
11、ntended for Outdoor Use; Revision to the Mandrel Diameter and Related Testing Requirements; Reinstatement of Previously Deleted Requirements for Thickness of Overall Jacket on Deep Well Pump Cables; Clarifi cation to Several Tables Addressing Various Requirements for Types RW75, RW90, RWU75, and/or
12、RWU90 cables; and Miscellaneous Editorial Wording Revisions RATIONALE Proposal submitted by: Mike Leibowitz, NEMA, on behalf of the CANENA Wire and Cable THSC These proposals were submitted by the CANENA Technical Harmonization Subcommittee (THSC) 20, Building Wire and Cable, the working group respo
13、nsible for the trinational Standard for Thermoset- Insulated Wires and Cables, UL 44. The rationale for each proposed change is provided in the summary table below. The THSCs proposal also incorporates proposed revisions from R. Konnick, Rockbestos to revise Tables 11, 15, and 19 to include Type RW7
14、5. Mr. Konnicks proposal was presented to, and accepted by, the THSC. Note: The proposal includes only those requirements from UL 44 which are proposed to be revised. ClauseAmendmentRationale Clause 3, General 3.2.1Add references to the trinational test methods standards These are needed as UL 44 no
15、w references those standards 3.2.2Delete reference to ASTM B 189The standard no longer recognizes lead alloy coated wires Clause 4, Conductors 4.1.1Reorganization of requirementEditorial 4.1.2Indicate national differences in the aluminum conductors permitted In Mexico, aluminum conductors can be AA
16、8000 series alloy or 1350, while in Canada and the U.S., these must be AA 8000 series alloy 4.1.4.2Delete references to lead-alloy conductorsThe standard no longer recognizes lead alloy coated wires 4.2.1.1Change meet to comply withEditorial 4.7Add requirements for protective materials applied betwe
17、en the jacket and insulated conductors Recognizes the introduction of new protective materials in the marketplace 4.10.1Correct the reference to requirements for evaluating new materials Editorial 4.10.2Remove references to Annex H.The standard does not recognize conductors having insulation thickne
18、sses other than those specifi ed in the NEC. Change meet to comply withEditorial 4.11.1, 4.11.2Change meet to comply withEditorial Clause 5, Test Requirements 5.2.3Replace the reference to clause 8.2 with a reference to the trinational test methods standard The method is now found in UL 2556; CSA C2
19、2.2 No. 2556; NMX-J-556-ANCE MAY 4, 2007SUBJECT 44-2- Table Continued on Next Page Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 05/15/2007 23:37:37 MDTNo reproduction or networking permitted without
20、 license from IHS -,-,- FOR INTERNAL UL OR CSDS USE ONLY NOT FOR OUTSIDE DISTRIBUTION Table Continued ClauseAmendmentRationale 5.3.1.1Revise the clause to apply to either solid or stranded conductors, rather than solid and “all other” conductors There are no known constructions other than solid and
21、stranded Replace the reference to clause 8.3.1 with a reference to the trinational test methods standard The method is now found in UL 2556; CSA C22.2 No. 2556; NMX-J-556-ANCE 5.3.2Add “(3.31 8.37 mm2(12 8 AWG) conductors only” to the title To clarify the size range to which the test applies Reword
22、the requirements and remove the national deviation for Mexico The requirements are reworded for clarifi cation. The national deviation for Mexico is removed since the test now appears in UL 2556 / CSA C22.2 No. 2556 / NMX-J-556-ANCE and applies in all countries. 5.4.1.1Replace the reference to claus
23、e 8.4 with a reference to the trinational test methods standard. The method is now found in UL 2556; CSA C22.2 No. 2556; NMX-J-556-ANCE Add, “Composite insulation systems shall be tested as a unit.” To clarify that components of composite systems should not be separated 5.5.1Change meet to comply wi
24、thEditorial 5.5.2.1Replace the reference to clause 8.5 with a reference to the trinational test methods standard. The method is now found in UL 2556; CSA C22.2 No. 2556; NMX-J-556-ANCE 5.6Replace the reference to clause 8.6 with a reference to the trinational test methods standard. The method is now