1、FOR INTERNAL UL OR CSDS USE ONLY NOT FOR OUTSIDE DISTRIBUTION Subject 583 July 14, 2006 SUMMARY OF TOPICS The following changes in requirements are being proposed: 1. Addition of defi nitions for an arcing or sparking component and for a heat generating source 2. Editorial revisions to 3.1 3. Clarif
2、i cation of the construction requirement in 5.6 4. Revision to address requirements for cables that have abrasive resistant sleeves in 6.2 5. Revision to make the requirements identical for Type E, EE and ES trucks in 8.1 6. Revision to add more cord types to 8.8 7. Clarifi cation of 9.1 and 9.4 8.
3、Revision to modify the requirements for the wire size in 9.2 9. Addition of requirements for nonmetallic battery covers to 10.7 10. Revisions to the requirements for batteries in 11.1 and 11.3 11. Revisions to the requirements for battery leads in 12.1 12. Addition of requirements for external charg
4、ing cables in 13.6 13. Replacement of the requirements for power circuits with requirements for low-voltage limited energy circuits in Section 16 14. Revision to the abnormal operation test requirements in 19.1 15. Revisions to clarify the requirements in 19.2 16. Clarifi cation of the abnormal oper
5、ation requirements in 19.3 17. Revision to the temperature test requirements in 20.1.3 18. Revision to specify the duration of the temperature test in 20.1.4 19. Deletion of 20.1.5 20. Revisions to add requirements regarding thermal cut-back features in 20.1.6 Copyright Underwriters Laboratories Inc
6、. Provided by IHS under license with ULLicensee=Army Northwestern Div./7838506130 Not for Resale, 08/30/2006 05:58:13 MDTNo reproduction or networking permitted without license from IHS -,-,- FOR INTERNAL UL OR CSDS USE ONLY NOT FOR OUTSIDE DISTRIBUTION 21. Clarifi cation of the temperature test req
7、uirement in 20.1.7 22. Editorial correction for 21.1 23. Revisions to add requirements for protective devices in 21.2, 23.1.1 and 25.2 24. Revisions to the dielectric voltage withstand test requirements in 22.1 25. Revisions to the burnout requirements in 24.7 26. Editorial revision to 31.3 STP BALL
8、OTS DUE: August 14, 2006 COMMENTS DUE: August 28, 2006 These proposals are the result of the STP 583 meeting held on August 30 and 31, 2005 at ULs Northbrook office. There are still outstanding proposals for UL 558 and UL 583 that continue to be worked on by the following task groups: 1. FUEL SYSTEM
9、 REQUIREMENTS FOR UL 558 TASK GROUP Objective: To revise requirements involving the engine system (including fuel pumps, fuel lines, etc.). 2. FLAMMABILITY OF NONMETALLIC MATERIALS (INCLUDING ACOUSTICAL MATERIAL, PLASTICS, ETC.) IN UL 558 AND UL 583 TASK GROUP Objective: To develop proposals for non
10、metallic materials in the engine compartment. 3. EXHAUST SYSTEM AND INTAKE SYSTEM TESTS FOR UL 558 TASK GROUP Objective: To develop proposals to revise the exhaust system and intake system tests (including the backfi re defl ection tests). If you are interested in joining any of these task groups, p
11、lease contact the Project Manager (Megan.M.C) or the Chair for STP 583 (Sonya.M.B). Other proposals that have been submitted via ULs Collaborative Standards Development System (CSDS) will be distributed for preliminary review and comment prior to ballot. For your convenience in review, proposed addi
12、tions to existing requirements are shown underlined and proposed deletions are shown lined-out. 1. Addition of defi nitions for an arcing or sparking component and for a heat generating source RATIONALE Proposal submitted by: Christopher Merther, Industrial Truck Association Defi nitions are needed
13、for an arcing or sparking component and a heat generating source. PROPOSAL 2.4.3 ARCING OR SPARKING COMPONENT A component that emits arcs or sparks under normal operating conditions (e.g. motor brushes or contactor). JULY 14, 2006SUBJECT 583-2- Copyright Underwriters Laboratories Inc. Provided by IH
14、S under license with ULLicensee=Army Northwestern Div./7838506130 Not for Resale, 08/30/2006 05:58:13 MDTNo reproduction or networking permitted without license from IHS -,-,- FOR INTERNAL UL OR CSDS USE ONLY NOT FOR OUTSIDE DISTRIBUTION 2.4.4 HEAT GENERATING SOURCE A non-arcing/non-sparking compone
15、nt that has a stabilized temperature greater than 158F (90C) during normal operation. 2. Editorial revisions to 3.1 RATIONALE Proposal submitted by: Christopher Merther, Industrial Truck Association In 3.1(a), the standard references B56.1-1988. This is no longer the latest version of B56.1. In 3.1(
16、b), the standard references NFPA 505-1992. This is no longer the latest version of NFPA 505. PROPOSAL 3 Reference Standards 3.1 Other standards applying to power-operated industrial trucks are: a) Safety Standard for Powered Industrial Trucks Low Lift and High Lift Trucks, ANSI/ASME B56.11988, which
17、 contains requirements relating to the elements of design, operation, and maintenance of powered industrial trucks; b) Standard for Powered Industrial Trucks Including Type Designations, Areas of Use, Maintenance and Operation, ANSI/NFPA 5051992, which relates to a classifi cation of industrial truc
18、ks as to areas of use, maintenance, and operation; and c) Standard for Internal Combustion Engine-Powered Industrial Trucks, UL 558, which contains requirements relating to risk of fi re. 3. Clarifi cation of the construction requirements in 5.6 RATIONALE Proposal submitted by: Don Hudak, Nissan For
19、klift Corp., North America 5.6 should be rewritten to clarify the requirement and correct the reference. PROPOSAL 5.6 Steel, other than stainless, used in accordance with (b2) of the Exception to 5.4 5.5 shall be zinc-coated, cadmium-plated, or equivalently protected against corrosion. 4. Revision t
20、o address requirements for cables that have abrasive resistant sleeves in 6.2 RATIONALE Proposal submitted by: Christopher Merther, Industrial Truck Association The standard indicates that lead wires exiting a motor through the case shall pass through openings provided with an insulation bushing fas
21、tened in place. At the STP 583 meeting held on August 30 and 31, 2005 at ULs Northbrook office, meeting participants suggested that the text provided with an insulating bushing fastened in place be replaced with as defi ned in 8.10. JULY 14, 2006SUBJECT 583-3- Copyright Underwriters Laboratories Inc
22、. Provided by IHS under license with ULLicensee=Army Northwestern Div./7838506130 Not for Resale, 08/30/2006 05:58:13 MDTNo reproduction or networking permitted without license from IHS -,-,- FOR INTERNAL UL OR CSDS USE ONLY NOT FOR OUTSIDE DISTRIBUTION PROPOSAL 6.2 When lead wires of a motor do not
23、 pass out of the motor directly into an acceptable raceway, or when they are brought out through the motor case, they shall pass through openings as defi ned in 8.10 provided with an insulating bushing fastened in place. 5. Revision to make the requirements identical for Type E, EE and ES trucks in
24、8.1 RATIONALE Proposal submitted by: Christopher Merther, Industrial Truck Association The term “braid” should be defi ned. The requirement should not be different from E to EE and ES trucks. It would be better if the requirement was the same for all trucks. PROPOSAL 8 Wiring 8.1 The internal wiring