0.5T净水处理系统使用说明书.doc
《0.5T净水处理系统使用说明书.doc》由会员分享,可在线阅读,更多相关《0.5T净水处理系统使用说明书.doc(28页珍藏版)》请在三一文库上搜索。
1、500L/h Reverse osmosis system Instructions500升/小时净水处理系统 500 l / h pure water treatment system 使用说明书Manual北京海德能科技有限公司Energy Technology Co., Ltd. Beijing Hyde电话:086-010-52335860Phone :086-010-52335860公司地址:北京市通州区次渠镇经海七路一号光联工业园区二区二号Address: Town, Tongzhou District, Beijing views the Drainage Road No. 7
2、by the sea of light district on the 2nd Joint Industrial Park II目 录CONTENTS一、系统说明31.the system shows3二、安装说明.4Second. Installation instructions4三、操作说明.6third. instructions 6四、系统常见故障排除15fourth. the system common trouble shooting. 10五、水处理设备污染紧急清洗.12fifth. Water Treatment Equipment Pollution Emergency c
3、leaning12六、水处理设备的停运保护17sixth.water treatment equipment outage protection.17七、设备参数.19seventh, device parameters719八、设备随机配件单20Eighth.Equipment accessories. Random20一、系统说明System本系统是以江河、湖泊、地下水作为水源(水源应无明显浑浊物),采用多级膜法处理。标准产水量500升/小时。The system is based on rivers, lakes, groundwater as a source of water (no
4、 water turbid material), multi-stage membrane treatment. Standard Production Capacity 500 l / hour.按每人/每天需要3升水计算,标准产水量每天可满足4000-5000人的需求。精滤系统在正常工作状态下做为反渗透系统的前处理,用于保护反渗透膜,提高设备使用寿命。Per person 3 liters of water every day to calculate the normal production of water per day can meet4000-5000 population.
5、Ultrafiltration system as the pre-treatment of reverse osmosis system in normal working conditions, used to protect the reverse osmosis and enhance equipment life.反渗透系统出水水质达到国标饮用净水水质标准(CJ94-2005)理化指标。water quality of Reverse osmosis systems : the national standard, Drinking Water Quality Standards (
6、CJ94-2005) physical.系统流程:System process:原水通过原水泵进入粗滤过滤器,过滤精度20m,过滤出大颗粒杂质、泥砂、悬浮物;再输送到一级精密过滤器,过滤精度10m,过滤出小颗粒杂质、絮状物、胶体等;经过一级精密滤器的水进入二级精密滤器,过滤精度1m,过滤更小的杂质,病菌,胶体,铁锈及大分子有机物等物质;经过净化的水通过高压泵加压进入反渗透系统,生产出纯净水。filtration accuracy filter of Rough filtration is of 20m, to filter out large particle impurities, sedi
7、ment, suspended solids;then go to first class ultrafilter, filter rating 10m, the little particle impurity, colloid will be filtered out; after first class filter then come into second ultrafilter, filter rating 1m, filt less colloid,germina,colloid,rust and big particles organic matter, etc. water
8、after purified go through high pressure pump go into RO system, produce pure water.二、安装说明Second. Installation instructions1、 选择水源地附近较平整的空地,将设备主机固定,关闭万向轮开关。 1, select the water source near the ground than the flat, the device host fixed, shutdown The Moxianglun switch.2、 在主机附近选择一个稍高平台(若无平台可以放置一张桌子代替平
9、台)放置自升式纯水箱(便于灌装取水)。2.Put the jack-up pure water container on the a little higher platform close to main machine, its easy to take water. ( a table can instead of the platform if there is no platform )3、 将取水接口后放入自升式原水箱中,将原水箱出口与原水泵接口C2连接(注意:1英寸管,长为2米,两头带快接);连接废水接口C4(注意:1英寸管长为5米,不带快接),要求排水通畅;将纯水出口C3与纯水
10、箱进口连接(注意:1/2英寸管,长为3米,两头带快接);将灌装口与纯水箱出口连接注意:(1/2英寸管,长为2米,带快接和阀门)。put the taking water mouth into the jack-up raw water container, then connect raw water box outlet with raw water pump interface C2. ( caution: 1 inch pipe, 2 meters length, quick union in two ends ); connect waste water interface C4(ca
11、ution: 1 inch pipe, 5 meters length, without quick union), require drain fluently, connect pure water outlet C3 with pure water box inlet( caution:1/2 inch pipe, 3 meters length, with quick union in 2 ends); connect fill water mouth with pure water box outlet(caution: 1/2 inch pipe, 2 meters length,
12、 with quick union and valve)4、检查所有管路连接处是否密封,所有接触点是否连接牢固。4,Check all pipe joints are sealed, all the contacts are securely connected.5、打开配电箱,检查所有连接点是否牢固,将380V,50Hz电源连接到接口11、12、13、N;连接地线D5。5,open the distribution box, check all connections are solid, the 380V, 50Hz power supply connected to the interf
13、ace, 11,12,13, N, connecting ground D5. 6、反渗透膜元件的装入 RO membrance module load在膜元件装入压力容器之前,准备好必要的工具、材料和防护用品,如活扳手、内六角扳手,一字螺丝刀、甘油、橡皮锤、手套等。按用户光盘的方法取下压力容器顶端的端板,将压力容器清洗、擦拭干净,并用毛巾或海绵浸甘油均匀涂抹压力容器内壁,使内壁润滑,便于膜元件的装入。Before load RO module, get necessary tools, material, and protective articles ready, for example,
14、 clyburn spanner, socket head wrench, Straight Screwdriver, Glycerin, rubber mallet, glove and so on. Take down end plate on the top of pressure vessel according to user CD, wash pressure vessel, wipe it clean, and use towel or sponge wipe inner of pressure vessel and make it lubricate easy to load
15、membrane module. (1) 反渗透膜组件安装前的准备:Preparation of RO loading 清除供水管内的垃圾、油、金属粉可根据需要进行配管系统内的药品清洗或注入清洗剂(设备出厂前以做初步清理)。Make clear of rubbish, oil, metal powder based on requirement of cleaner( equiptment did basic cleansing before leaving plant) 供给水质的确认:至少要对压力容器通水30min,确认反渗透膜的供给水是否符合要求。对于聚酰胺复合膜,要确认无残留游离氯存在
16、。Supply water quality confirmation: watering no less than 30min for pressure vessel, confirm if RO supply water fulfill requirement. Make sure there is no Dissociation chlorine to Gathers the amide compound membrane. 必要零部件的准备:从纸板箱内的附件盒里将零部件取出。先确认膜元件的附属零部件及必要数量,见下表:Necessary spare parts: take out spa
17、re sparts in box from pure wooden crate. Confirm necessary spare parts number of membrane module, as follow sheet:零部件名称Necessary spare parts name盐水密封垫圈Seawater seal washer连接配件Connection fittings必要数量Necessary number11注释:该配件已安装Note: fittings installed压力容器内部的检查: 取下压力容器上端的端板。用干净水冲洗已打开的压力容器,并将容器内部的垃圾或异物除
18、去。Internal inspection of pressure vessel: take out end plate on the top of pressure vessel, wash clean opened pressure vessel, and make clear internal rubbish.(2) 反渗透膜元件的安装RO membrane module loading 从纸板箱中取出膜元件,拆去塑料包装袋。Take out membrance module, then take down plastic sack.查看盐水密封圈是否安装(盐水密封圈一般在膜出厂前已安装
19、好);若没安装请在膜元件上安装盐水密封圈:盐水密封的方向如图4-1所示。如果逆向安装则不能发挥其作用,务请注意.Check seawater seal packing collar(seawater seal packing collar is loaded before leaving plant); please load seawater seal packing collar, Direction as shown in Figure 4-1. Caution: anti direction loading is not allowed. 装填膜元件:将膜元件带盐水密封圈的一端从压力容
20、器的顶端插入,将元件的2/3慢慢推入,进行如图42、图43所示。这时,要注意勿触及压力容器的边缘。Loading membrane module: put seawater seal packing collar side in pressure vessel, put 2/3 slowly, same as figure 4-2, and 4-3. dont touch vessel edge.装填后续膜元件:重复步骤 (图4-2-图4-3)直到所有元件都装入压力容器内,元件和压力容器的长度决定装填数量本套设备每支压力容器装填1支膜元件。Load following part: Redund
21、ant step(picture 4-2-picture 4-3) until put all parts in pressure vessel, parts and vessel length decide membrane loading number, loading 1 piece of membrane module every pressure vessel in this system. 安装供给水侧的端板:根据用户光盘的方法,在压力容器的供给水侧安装上端板。Load end plate of water supply: load end plate at pressure ve
22、ssel supply water side according to user CD.连接好端板处的管道。Connect end plate pipeline well.(3) 装填膜元件后的检查Inspection 通水确认:仔细检查管配件接续是否正确、螺丝是否拧紧后再开始进行通水试验,通水时要注意尽量让水压慢慢上升。Watering confirmation: check whether pipeline connection correct, Whether the screw does screw tight, then start to watering test, try to
23、make water pressure go up slowly when watering. 调整至设定的产水量和回收率:密切注意给水、浓缩水的流量计的同时,调整到设定的制水量和回收率,如果没有压力损失或其他问题时,让这种运行状态持续lh。Adjust to set Water yield and returns-ratio, meanwhile Watch out for gives the water, the thick shrinkage flowmeter. Keep this running situation 1h if there is no pressure lost or