IEC-61169-39-2009.pdf
IEC 61169-39 Edition 1.0 2009-06 INTERNATIONAL STANDARD Radio-frequency connectors Part 39: Sectional specification for CQM series quick lock RF connectors IEC 61169-39:2009(E) ® -,-,- THIS PUBLICATION IS COPYRIGHT PROTECTED Copyright © 2009 IEC, Geneva, Switzerland All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information. IEC Central Office 3, rue de Varembé CH-1211 Geneva 20 Switzerland Email: 0H inmailiec.ch Web: 1H www.iec.ch About the IEC The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related technologies. About IEC publications The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the latest edition, a corrigenda or an amendment might have been published. ? Catalogue of IEC publications: 2H www.iec.ch/searchpub The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,). It also gives information on projects, withdrawn and replaced publications. ? IEC Just Published: 3H www.iec.ch/online_news/justpub Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available on-line and also by email. ? Electropedia: 4H www.electropedia.org The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical Vocabulary online. ? Customer Service Centre: 5H www.iec.ch/webstore/custserv If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service Centre FAQ or contact us: Email: 6H csciec.ch Tel.: +41 22 919 02 11 Fax: +41 22 919 03 00 IEC 61169-39 Edition 1.0 2009-06 INTERNATIONAL STANDARD Radio-frequency connectors Part 39: Sectional specification for CQM series quick lock RF connectors INTERNATIONAL ELECTROTECHNICAL COMMISSION U ICS 33.120.30 PRICE CODE ISBN 2-8318-1047-3 ® Registered trademark of the International Electrotechnical Commission ® 2 61169-39 © IEC:2009(E) CONTENTS FOREWORD. 0H 4 1 Scope. 1H 6 2 Normative references . 2H 6 3 Mating interface and gauge information 3H 6 3.1 Dimensions-General connectors Grade 2 . 4H 7 3.1.1 Connector with pin-centre contact 5H 7 3.1.2 Connectors with socket-centre contact 6H 8 3.2 Gauges . 7H 9 3.2.1 Connectors with socket-centre contact 8H 9 3.3 Dimensions standard test connectors Grade 0. 9H 11 3.3.1 Connector with pin-centre contact 10H 11 3.3.2 Connector with socket-centre contact 11H 13 4 Quality assessment procedure 12H 14 4.1 General. 13H 14 4.2 Rating and characteristics (see Clause 6 of IEC 61169-1) . 14H 14 4.3 Test schedule and inspection requirements. 15H 17 4.3.1 Acceptance tests . 16H 17 4.3.2 Periodic tests 17H 18 4.4 Procedures 18H 19 4.4.1 Quality conformance inspection. 19H 19 4.4.2 Qualification approval and its maintenance 20H 19 5 Instructions for preparation of detail specifications . 21H 19 5.1 General. 22H 19 5.2 Identification of the detail specification 23H 20 5.3 Identification of the component 24H 20 5.4 Performance 25H 20 5.5 Marking, ordering information and related matters. 26H 20 5.6 Selection of tests, test conditions and severities 27H 20 5.7 Blank detail specification pro-forma for type CQM connector. 28H 21 Bibliography 29H 26 Figure 1 Connector with pin-centre contact (for dimensions, see Table 1) 30H 7 Figure 2 Connector with socket-centre contact (for dimensions, see Table 2) 31H 8 Figure 3 Gauge for outer contact of socket connector (for dimensions, see Table 3) 32H 9 Figure 4 Gauge pin for socket contact (for dimensions, see Table 4) . 33H 9 Figure 5 Connector of pin-centre contact (for dimensions, see Table 5) 34H 11 Figure 6 Standard test connector with socket-centre contact (for dimensions, see Table 6) 35H 13 Table 1 Dimensions of connector with pin-centre contact. 36H 7 Table 2 Dimensions of connector with socket-centre contact 37H 8 Table 3 Dimensions of gauge for outer contact of socket connector . 38H 9 Table 4 Dimensions of gauge pin for socket contact. 39H 10 Table 5 Dimensions of connector with pin-centre contact. 40H 12 61169-39 © IEC:2009(E) 3 Table 6 Dimensions of standard test connector with socket-centre contact 41H 14 Table 7 Ratings and characteristics . 42H 15 Table 8 Acceptance tests. 43H 17 Table 9 Periodic tests 44H 18 4 61169-39 © IEC:2009(E) INTERNATIONAL ELECTROTECHNICAL COMMISSION _ RADIO-FREQUENCY CONNECTORS Part 39: Sectional specification for CQM series quick lock RF connectors FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non- governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 61169-39 has been prepared by subcommittee 46F: RF and microwave passive components, of IEC technical committee 46: Cables, wires, waveguides, R.F. connectors, R.F. and microwave passive components and accessories. The text of this standard is based on the following documents: CDV Report on voting 46F/107/CDV 46F/133/RVC Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. 61169-39 © IEC:2009(E) 5 The committee has decided that the contents of this publication will remain unchanged until the maintenance result date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended. A list of all parts of the IEC 61169 series can be found, under the general title Radio- frequency connectors, on the IEC website. A bilingual version of this publication may be issued at a later date. 6 61169-39 © IEC:2009(E) RADIO-FREQUENCY CONNECTORS Part 39: Sectional specification for CQM series quick lock RF connectors 1 Scope CQM series quick lock connectors with characteristic impedance 50 are used for high power microwave applications, connecting with RF cables or microstrips. The operating frequency limit is at least 4 GHz. This sectional specification provides information and rules for the preparation of detail specifications for CQM series quick lock RF connectors together with the pro forma blank detail specification (DS). It also prescribes mating interface dimensions for general purpose connectors, dimensional details of standard test connectors grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to CQM series connectors. This specification indicates the recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61169-1:1992, Radio-frequency connectors Part 1: Generic specification General requirements and measuring methods 3 Mating interface and gauge information All undimensioned pictorial configurations are for reference purposes only. -,-,- 61169-39 © IEC:2009(E) 7 3.1 Dimensions-General connectors Grade 2 3.1.1 Connector with pin-centre contact Note 1 Note 2 Note 4 R1,5 +0,1 0 Note 3 p m n h i b asec d l fg k j u vt IEC 993/09 Figure 1 Connector with pin-centre contact (for dimensions, see Table 1) Table 1 Dimensions of connector with pin-centre contact Reference mm Note min max a 5,96 6,04 Diameter b 7(nominal) Diameter c 15,85 16,25 Diameter d 16,90 17,10 Diameter e 18,00 18,20 Diameter f 21,00 21,20 Diameter g 21,90 22,10 Diameter h 8,90 9,20 i 3,70 3,90 j 4,30 4,50 k - 9,80 l 0,30 0,50 m 8,80 9,00 n 7,20 7,40 p 4,20 4,40 s 23,20 23,30 Diameter t 35,00 35,20 Diameter u 2,10 2,30 v 26,9 27,2 Diameter NOTE 1 Mechanical reference plane. NOTE 2 The spring force is 50 N to 60 N max. NOTE 3 Tolerances of dimensions are to meet the requirements of characteristic impedances. NOTE 4 Ring. 8 61169-39 © IEC:2009(E) 3.1.2 Connectors with socket-centre contact Note 6 Note 5 Note 4 Note 3 Note 2 Note 1 g f u i j h n e m a b c d q p l k rs 1,5 × 45° IEC 994/09 Figure 2 Connector with socket-centre contact (for dimensions, see Table 2) Table 2 Dimensions of connector with socket-centre contact Reference mm Note min max a 7(nominal) Diameter (Note 1) b 15,85 16,25 Diameter c 16,70 16,90 Diameter d 17,80 18,00 Diameter e 22,10 22,30 Diameter f 6,30 6,50 g 9,10 9,30 h 12,75 12,85 i 0,20 0,40 j - 0,20 k 7,00 7,50 l 8,50 9,00 m 23,60 23,80 Diameter n 35,20 35,40 Diameter p 0,80 1,00 q 1,10 1,30 r 1,60 - s 2,60 - u 4,90 5,20 NOTE 1 Design for slotting optional, closed contacts should meet electrical and mechanical requirements. NOTE 2 Design for slotting optional, flared contacts Ød should be flared to Ø18,4Ø18,5. NOTE 3 Mechanical reference plane. NOTE 4 Three steel balls, Ø3. NOTE 5 The spring force is 2 N to 6 N, movement is 1,60 mm min. NOTE 6 Ring. -,-,- 61169-39 © IEC:2009(E) 9 3.2 Gauges 3.2.1 Connectors with socket-centre contact 3.2.1.1 Gauge for outer contact of socket connector v w s t u IEC 995/09 Figure 3 Gauge for outer contact of socket connector (for dimensions, see Table 3) Table 3 Dimensions of gauge for outer contact of socket connector Gauge A (for sizing purposes) Gauge B (for measurement of gauge retention force for outer conductor) Mass (weight) of gauge: 200 g ± 5 g mm mm Ref. min max min max Note s 18,05 18,10 18,15 18,18 t 18,70 18,80 18,70 18,80 u 20,00 20,80 20,00 20,80 v 9,50 9,60 9,40 9,50 w 1,30 1,50 1,30 1,50 NOTE Material: steel, polished, surface roughness: Ra0,4 m. 3.2.1.2 Test sequence Gauge A shall be placed over the outer contact of the connector once. This is a sizing operation. After this, gauge B shall be placed over the outer contact in a vertical position. The gauge shall be retained. 3.2.1.3 Gauge pin for socket-centre contact a 5,6 mm min. 7,6 mm max. IEC 996/09 Figure 4 Gauge pin for socket contact (for dimensions, see Table 4) 10 61169-39 © IEC:2009(E) Table 4 Dimensions of gauge pin for socket contact Gauge C (for sizing purposes) Gauge D (for measurement of gauge retention force for centre contact) Mass (weight) of gauge: 600 g ± 5 g mm mm Ref. min max min max a 6,05 6,10 5,95 6,00 NOTE Material: steel, polished, surface roughness: Ra0,4 m. 3.2.1.4 Test sequence Test pin gauge C shall be inserted into the centre contact three times with a minimum depth of 5,6 mm. This is a sizing operation and should only be carried out when the socket centre contact is removed from the connector. After this, gauge D shall be inserted and held in the vertical position. The gauge shall be retained. This test can also be carried out on connector when the socket centre contact is not removed once the sizing operation has been carried out on the contact whilst it was removed from the connector. 61169-39 © IEC:2009(E) 1