BS-8213-4-2007.pdf
《BS-8213-4-2007.pdf》由会员分享,可在线阅读,更多相关《BS-8213-4-2007.pdf(38页珍藏版)》请在三一文库上搜索。
1、BS 8213-4:2007 Windows, doors and rooflights Part 4: Code of practice for the survey and installation of windows and external doorsets ICS 91.060.50 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BRITISH STANDARD Licensed Copy: London South Bank University, London South Bank
2、University, Mon Apr 02 00:22:30 GMT+00:00 2007, Uncontrolled Copy, (c) BSI Publishing and copyright information The BSI copyright notice displayed in this document indicates when the document was last issued. BSI 2007 ISBN 978 0 580 50205 7 The following BSI references relate to the work on this sta
3、ndard: Committee reference B/538/1+2 Draft for comment 06/30151736 DC Publication history First published June 1990 Second (present) edition, March 2007 Amendments issued since publication Amd. no.DateText affected BS 8213-4:2007 Licensed Copy: London South Bank University, London South Bank Univers
4、ity, Mon Apr 02 00:22:30 GMT+00:00 2007, Uncontrolled Copy, (c) BSI BSI 2007i BS 8213-4:2007 Contents Foreword iii 1Scope 1 2Normative references 1 3Terms and definitions 2 4Materials 3 5Surveying for replacement windows and doorsets 4 6Surveying for new build 9 7Removal of existing windows and door
5、sets 9 8Installation 11 Annexes Annex A (informative) Typical checklists 22 Annex B (informative) Window and doorset removal techniques 24 Annex C (informative) Examples of replacement frame position and joint construction 27 Bibliography 31 List of figures Figure 1 Measurement of flat windows and d
6、oorsets 7 Figure 2 Fixing positions for PVC-U windows and doorsets 13 Figure 3 Fixing distances for timber windows and doorsets 14 Figure 4 Fixing distances for aluminium windows and doorsets 15 Figure 5 Setting and location block position 19 Figure A.1 Typical surveyors checklist 22 Figure A.2 Typi
7、cal final inspection checklist 23 Figure B.1 Cutting through transoms and mullions 24 Figure B.2 Cutting through the outer frame 25 Figure C.1 Flush reveal with joint width less than 6 mm and frame bridging DPM 27 Figure C.2 Flush reveal with joint width from 6 mm to 15 mm and frame bridging DPM 27
8、Figure C.3 Flush reveal with external render, for replacement frames 28 Figure C.4 Flush reveal with external render, for replacement windows/doorsets with frame shuffled into position 28 Figure C.5 Box sash replacement 29 Figure C.6 Frame forward of DPM 29 Figure C.7 Sub-sill arrangement 30 Figure
9、C.8 Head arrangement 30 List of tables Table 1 Recommended deductions from structural opening sizes 8 Summary of pages This document comprises a front cover, an inside front cover, pages i to iv, pages 1 to 31 and a back cover. Licensed Copy: London South Bank University, London South Bank Universit
10、y, Mon Apr 02 00:22:30 GMT+00:00 2007, Uncontrolled Copy, (c) BSI BS 8213-4:2007 ii BSI 2007This page deliberately left blank Licensed Copy: London South Bank University, London South Bank University, Mon Apr 02 00:22:30 GMT+00:00 2007, Uncontrolled Copy, (c) BSI BSI 2007iii BS 8213-4:2007 Foreword
11、Publishing information This part of BS 8213 is published by BSI and came into effect on 30 March 2007. It was prepared by Subcommittees B/538/1, Windows, and B/538/2, Doors, under the authority of Technical Committee B/538, Doors, windows, shutters, hardware and curtain walling. A list of organizati
12、ons represented on these committees can be obtained on request to their secretary. Supersession This part of BS 8213 supersedes BS 8213-4:1990, which is withdrawn. Relationship with other publications BS 8213 is published in two parts: Part 1: Design for safety in use and during cleaning of windows,
13、 including door-height windows and roof windows Code of practice; Part 4: Code of practice for the survey and installation of windows and external doorsets. This part of BS 8213 is intended to supplement British and European product standards for windows and doorsets. Information about this document
14、 This is a full revision of the standard. It brings up to date the guidance given in the previous edition and takes into account the publication of a number of European Standards published since 1990. Use of this document As a code of practice, this part of BS 8213 takes the form of guidance and rec
15、ommendations. It should not be quoted as if it were a specification and particular care should be taken to ensure that claims of compliance are not misleading. Any user claiming compliance with this part of BS 8213 is expected to be able to justify any course of action that deviates from its recomme
16、ndations. Due to the wide variety of installation conditions, it is not possible to cover all applications completely. This part of BS 8213 gives guidance on those good building practices that are expected to ensure satisfactory installation. Windows and external doorsets are available in a range of
17、 materials, each material having a unique performance characteristic. The surveyor and installer need to be aware of the material being used, and any additional manufacturers recommendations for survey and installation. Licensed Copy: London South Bank University, London South Bank University, Mon A
18、pr 02 00:22:30 GMT+00:00 2007, Uncontrolled Copy, (c) BSI BS 8213-4:2007 iv BSI 2007 Presentational conventions The provisions in this standard are presented in roman (i.e. upright) type. Its recommendations are expressed in sentences in which the principal auxiliary verb is “should”. Commentary, ex
19、planation and general informative material is presented in smaller italic type, and does not constitute a normative element. Contractual and legal considerations This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application
20、. Compliance with a British Standard cannot confer immunity from legal obligations. Attention is drawn to the Building Regulations 2000 and subsequent amendments 1, the Building (Scotland) Regulations 2004 2 and the Building Regulations (Northern Ireland) 2000 3, and to the need for Building Regulat
21、ions approval for the majority of window and external doorset installations. Licensed Copy: London South Bank University, London South Bank University, Mon Apr 02 00:22:30 GMT+00:00 2007, Uncontrolled Copy, (c) BSI BSI 20071 BS 8213-4:2007 1 Scope This part of BS 8213 gives recommendations for the s
22、urveying and installation of non-loadbearing windows and external doorsets of any material, to be installed vertically (within 15) into the external face of buildings. It gives guidance on the good practices necessary for the successful surveying and installation of windows and external doorsets in
23、both new build and replacement situations. It is primarily aimed at installations in dwellings but much of the guidance given is relevant to other types of installation. The guidance contained in this part of BS 8213 may also be applied to door assemblies, but does not cover the site assembly of ind
24、ividual components. This part of BS 8213 does not apply to load-bearing windows, load-bearing doorsets or roof windows. It does not cover curtain or ribbon walling, although its guidance also applies to separate window and door elements within those particular types of assemblies. It does not cover