1、2006 International Building Code Errata Page 1 of 10 2006 International Building Code Errata THIRD PRINTING (Updated December 17, 2007) CHAPTER 3 USE AND OCCUPANCY CALCULATION F TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa,j,m,n,p STORAG
2、Eb USE-CLOSED SYSTEMSb MATERIAL Gas (cubic feet at NTP) Liquid gallons (pounds) Unstable (reactive) 10d, g 50d,e 250d,e N/L (0.25)g (1)d (50)d N/L (Portions of table not shown remain unchanged. Delete note d for first row of Unstable/Gas Storage. Add note d to second row of Unstable/Liquid gallons U
3、se-Closed Systems. Posted 12-17-07) 2006 International Building Code Errata Page 2 of 10 THIRD PRINTING (Updated December 17, 2007) CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY F TABLE 415.3.1 MINIMUM SEPARATION DISTANCES FOR BUILDINGS CONTAINING EXPLOSIVE MATERIALS MINIMUM DIS
4、TANCE (feet) QUANTITY OF EXPLOSIVE MATERIALSa Lot linesb and inhabited buildingsc Pounds over Pounds not over Barridacedd Unbarricaded Separation of magazinesd,e,f 35,000 40,000 1,275 1,340 2,000 248 (Change to column three. Portions of table not shown remain unchanged. Posted 12-17-07) F TABLE 415.
5、8.2.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a HAZARD CATEGORY SOLIDS (pounds per square feet) LIQUIDS (gallons per square feet) GAS (feet3 NTP/square feet) PHYSICAL-HAZARD MATERIALS Oxidizer Class 4 Class 3 Class 2 Class 1 Combination Class 1, 2, 3 Note b
6、 0.003 0.003 0.003 0.003 Note b 0.03 0.003 0.03 0.003 0.03 0.003 0.03 0.003 Not Applicable (Change to column three. Portions of table not shown remain unchanged. Posted 12-17-07) 2006 International Building Code Errata Page 3 of 10 THIRD PRINTING (Updated December 17, 2007) CHAPTER 6 TYPES OF CONSTR
7、UCTION TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (hours) Row Roof construction, Column Type IIIA Add reference to note c (Reference to note c was editorially removed from Type IIB and Type IIIB for the 1st printing, however it was also deleted from IIIA unintentionally. pos
8、ted 12-17-07) 602.4.3 Roof framing. Wood-frame or glued-laminated arches for roof construction, which spring from the floor line or from grade and do not support floor loads, shall have members not less than 6 inches (152 mm) nominal in width and have not less than 8 inches (203 mm) nominal in depth
9、 for the lower half of the height and not less than 6 inches (152 mm) nominal in depth for the upper half. Framed or glued laminated arches for roof construction that spring from the top of walls or wall abutments, framed timber trusses and other roof framing, which do not support floor loads, shall
10、 have members not less than 4 inches (102 mm) nominal in width and not less than 6 inches (152 mm) nominal in depth. Spaced members shall be permitted to be composed of two or more pieces not less than 3 inches (76 mm) nominal in thickness where blocked solidly throughout their intervening spaces or
11、 where spaces are tightly closed by a continuous wood cover plate of not less than 2 inches (51 mm) nominal in thickness secured to the underside of the members. Splice plates shall be not less than 3 inches (76 mm) nominal in thickness. Where protected by approved automatic sprinklers under the roo
12、f deck, framing members shall be not less than 3 inches (76 mm) nominal in width. (Posted 12-17-07) 2006 International Building Code Errata Page 4 of 10 THIRD PRINTING (Updated December 17, 2007) CHAPTER 7 FIRE-RESISTANCE-RATED CONSTRUCTION TABLE 715.5 FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS TY
13、PE OF ASSEMBLY REQUIRED ASSEMBLY RATING (hours) MINIMUM FIRE WINDOW ASSEMBLY RATING (hours) Interior walls: Fire walls Fire barriers Smoke barriers and fire partitions All 1 1 1 NPa NPa 3/4 3/4 (Add blank rows between fire walls, fire barrier and smoke barrier to align requirements, Remainder of tab
14、le unchanged, posted 12-17-07) TABLE 720.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS Item 14 14-1.5 Construction column 2” x 4” wood studs 1” 16” on center with two layers 5/8” Type X gypsum wallboarde each side. Base layers applied vertically and nailed with 6d coolern or wa
15、llboardn nails at 9” on center. Face layer applied vertically or horizontally and nailed with 8d coolern or wallboardn nails at 7” on center. For nail-adhesive application, base layers are nailed 6” on center. Face layers applied with coating of approved wallboard adhesive and nailed 12” on center.
16、(Remainder of table unchanged, posted 12-17-07) TABLE 720.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS Item 21-1.1 Floor or Roof Construction column 21. Wood joists, floor trusses and flat or pitched roof trusses spaced a maximum 24” o.c. with ” wood structural panels with exterior glue applie
17、d at right angles to top of joist or top chord of trusses with 8d nails. The wood structural panel thickness shall not be less than nominal ” nor less than required by Chapter 23. (posted 12-17-07) Item 22-1.1 Floor or Roof Construction column 22.Wood joists, wood I-joists, floor trusses and flat or
18、 pitched roof trusses spaced a maximum 24” o.c. with ” wood structural panels with exterior glue applied at right angles to top of joist or top chord of trusses with 8d nails. The wood structural panel thickness shall not be less than nominal ” nor less than required by Chapter 23. (posted 12-17-07)
19、 2006 International Building Code Errata Page 5 of 10 THIRD PRINTING (Updated December 17, 2007) CHAPTER 10 MEANS OF EGRESS 1022.1 Horizontal exits. Horizontal exits serving as an exit in a means of egress system shall comply with the requirements of this section. A horizontal exit shall not serve a
20、s the only exit from a portion of a building, and where two or more exits are required, not more than one-half of the total number of exits or total exit width shall be horizontal exits. Exceptions: 1. Horizontal exits are permitted to comprise two-thirds of the required exits from any building or f
21、loor area for occupancies in Group I-2. 2. Horizontal exits are permitted to comprise 100 percent of the exits required for occupancies in Group I-3. At least 6 square feet (0.6 m2) of accessible space per occupant shall be provided on each side of the horizontal exit for the total number of people
22、in adjoining compartments. Every fire compartment for which credit is allowed in connection with a horizontal exit shall not be required to have a stairway or door leading directly outside, provided the adjoining fire compartments have stairways or doors leading directly outside and are so arranged