JIS-C-3663-2-2003-ENG.pdf
《JIS-C-3663-2-2003-ENG.pdf》由会员分享,可在线阅读,更多相关《JIS-C-3663-2-2003-ENG.pdf(28页珍藏版)》请在三一文库上搜索。
1、J IS JAPANESE I NDUSTR IAL STANDARD Translated and Published by Japanese Standards Association Rubber insulated cables- Rated voltages up to and including 450/750 V-Part 2 : Test methods ICs 29.060.20 Reference number : JIS C 3663-2 : 2003 (E) PROTECTED BY COPYRIGHT 15 S Copyright Japanese Standards
2、 Association Provided by IHS under license with JSALicensee=HP Monitoring/1111111164 Not for Resale, 01/07/2008 01:37:18 MSTNo reproduction or networking permitted without license from IHS -,-,- C 3663-2 : 2003 Foreword This translation has been made based on the original Japanese Industrial Standar
3、d revised by the Minister of Economy, Trade and Industry through deliberations at the Japanese Industrial Standards Committee, as the result of proposal for revision of Japanese Industrial Standard submitted by The Japanese Electric Wire to prepare Japanese Industrial Standard conforming with Intern
4、ational Standard; and to propose a draft of an International Standard which is based on Japanese Industrial Standard. Attention is drawn to the possibility that some parts of this Standard may conflict with a patent right, application for a patent after opening to the public, utility model right or
5、application for registration of utility model after opening to the public which have technical properties. The relevant Minister and the Japanese Industrial Standards Committee are not responsible for identifying the patent right, application for a patent after opening to the public, utility model r
6、ight or application for registration of utility model after opening to the public which have the said technical properties. JIS C 3663 consists of the following 8 parts under the general title Rubber insulated cables-Rated voltages up to and including 4501 750 V. Part 1 : General requirements Part 2
7、 : Test methods Part 3 I Heat resistant silicone insulated cables Part 4 : Cords and flexible cables Part 5 :Lift cables Part 6 :Arc welding electrode cables Part 7 : Heat resistant ethylene-vinyl acetate rubber insulated cables Part 8 : Cords for applications requiring high flexibility Date of Esta
8、blishment: 1998-03-20 Date of Revision: 2003-10-20 Date of Public Notice in Official Gazette: 2003-10-20 Investigated by: Japanese Industrial Standards Committee Standards Board Technical Committee on Electricity Technology JIS C 3663-2 : 2003, First English edition published in 2004-12 Translated a
9、nd published by: Japanese Standards Association 4-1-24, Akasaka, Minato-ku, Tokyo, 107-8440 JAPAN In the event of any doubts arising as to the contents, the original JIS is to be the final authority. O JSA 2004 All rights reserved. No part of this publication may be reproduced or utilized in any for
10、m or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. Printed in Japan PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=HP Monitoring/1111111164 Not for Resale
11、, 01/07/2008 01:37:18 MSTNo reproduction or networking permitted without license from IHS -,-,- C 3663-2 : 2003 Contents Page Introduction . 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 1.10 1.11 1.12 2 2.1 2.2 2.3 2.4 3 3.1 3.2 3.3 3.4 3.5 3.6 4 4.1 4.2 General Scope Normative references Classification of
12、 tests Sampling . Pre-conditioning . Test voltage Test temperature . Checking of the durability of colours and markings . Measurement of thickness of insulation . Measurement of thickness of sheath . Measurement of overall dimensions and ovality . Solderability test for untinned conductors . Electri
13、cal tests . Electrical resistance of conductors . Voltage test carried out on completed cables . Voltage test on cores . Insulation resistance at temperatures above 90 “C Tests of mechanical strength of completed flexible cables Flexing test . Static flexibility test . Wear resistance test . Tensile
14、 strength of the central heart of lift cables . Three pulley flexing test Kink test . Tests for mechanical properties after air oven and oxygen bomb ageing of insulation consisting of rubber compound IE 1 General Sampling and preparation . 1 1 1 1 2 2 3 3 3 3 3 3 4 4 5 5 6 6 6 7 7 9 11 12 12 12 14 1
15、4 14 PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=HP Monitoring/1111111164 Not for Resale, 01/07/2008 01:37:18 MSTNo reproduction or networking permitted without license from IHS -,-,- C 3663-2 2003 4.3 4.4 5 6 6.1 6.2 6.3 6.4 6.5 6.6
16、 Ageing procedure . Preparation of test pieces and tensile test . Flame retardance test for lift cables . Test for resistance to heat of textile braids . General Apparatus Sample . Preparation . Test procedure Requirement . 14 14 14 15 15 15 16 16 16 16 Annex (informative) Comparison table between J
17、IS and corresponding International Standard . 19 (ii) PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=HP Monitoring/1111111164 Not for Resale, 01/07/2008 01:37:18 MSTNo reproduction or networking permitted without license from IHS -,-,-
18、JAPANESE INDUSTRIAL STANDARD JIS C 3663-2 : 2003 Rubber insulated cables-Rated voltages up to and including 450/750 V- Part 2 : Test methods Introduction This Japanese Industrial Standard has been prepared based on the second edition of IEC 60245-2 Rubber insulated cables-Rated voltages up to and in
19、cluding 4501 750 V-Part 2 .- Test methods published in 1994 together with Amend- ment 1 (1997) and Amendment 2 (1997) with some modifications of the technical con- tents. Portions underlined with dots are the matters modified from the original Inter- national Standard. The list of modifications with
20、 the explanation is given in annex (informative). 1 General 1.1 This part of JIS C 3662 gives the test methods specified in all parts of JIS C 3662 (rubber insulated cables of rated voltages up to and including 450/ 750 V) as far as not laid down in JIS C 3660. NOTE : The International Standard corr
21、esponding to this Standard is as follows. In addition, symbols which denote the degree of correspondence in the contents between the relevant International Standard and JIS are IDT (identical), MOD (modified), and NEQ (not equivalent) according to ISO/IEC Guide 21. Scope . . . IEC 60245-2 : 1994 Rub
22、ber insulated cables-Rated voltages up to and including 4501 750 V-Part 2 : Test methods together with amendment 1 (1997) and amendment 2 (1997) (MOD) . 1.2 Normative references The following standards contain provisions which, through reference in this Standard, constitute provisions of this Standa
23、rd. If the indication of the year of publication is given to these referred standards, only the edition of the indicated year constitutes the provision of this Standard but the revi- sion and amendment made thereafter do not apply. The normative reference with- out the indication of the year of comi
24、ng into effect apply only to the most recent edition (including amendments). JIS C 3660-1-1 Common test methods for insulating and sheathing materials of NOTE : electric and optical cables-Part 1-1 :Methods for general appli- cation-Measurement of thickness and overall dimensions-Tests for determini