Net 装机维护 UniversalSASandACPCablingGuide.docx
《Net 装机维护 UniversalSASandACPCablingGuide.docx》由会员分享,可在线阅读,更多相关《Net 装机维护 UniversalSASandACPCablingGuide.docx(80页珍藏版)》请在三一文库上搜索。
1、NetAppxSASDiskShelvesUniversalSASandACPCablingGuideNetApp, Inc.495 East Java Drive Sunnyvale, CA 94089 U.S.Part number: 215-05500_D0September 2013Telephone:+1(408)822-6000Fax:+1(408)822-4501Supporttelephone:+1(888)463-8277Web:Feedback:doccommentsTableofContents3ContentsSAScablingfornewstoragesystems
2、5SAScablingrules5GeneralSAScablingrules5OnboardSASportrules8Shelf-to-shelfconnectionrules9Controller-to-shelf-connectionrules10Controller-to-controllerrule(FAS22xxsystemsonly)15CablingSASconnections15CompletingtheSAScablingworksheet15SAScablingworksheetrulesandtemplate16SampleSAScablingworksheetfora
3、32xx17SampleSAScablingworksheetforanHApair(non32xx,FAS22xx,orFAS20xx)19CablingSASports21SAScablingexamples26ExamplesofSAScablingforHApairswithquad-portHBAs26ExamplesofSAScablingforsingle-controllerconfigurationswithquad-portHBAs31ExamplesofSAScablingfor32xxsystems35ExamplesofSAScablingforPCMsystems3
4、7ExamplesofSAScablingforFAS2050systems44ExamplesofSAScablingforFAS2040systems48ACPcablingfornewstoragesystems51ACPcablingrules51GeneralACPcablingrules51ACPconnectivityrules51CablingACPconnections52CablingACPonsystemswithexternalSASstorage52CablingACPonPCMsystemswithnoexternalSASstorage59ACPcablingex
5、amples60ExamplesofACPcablingforHApairs60ExamplesofACPcablingforsingle-controllerconfigurations64GlossaryDocumentupdaterecord71Copyrightinformation73Trademarkinformation74Howtosendyourcomments75Index76SASCablingfornewStOrageSyStemSFornewstoragesysteminstallations,youmustunderstandthecablingrulesbefor
6、ecablingtheSASconnectionsforthediskshelves.Note:AlthoughthecablingrulesinthisdocumentapplytostretchMetroClustersystemswithSASdiskshelvesdirectlyattachedtothecontrollers,specificcablingproceduresforstretchMetroClustersystemsusingSASopticalcablescanbefoundintheConfiguringastretchMetroClustersystemwith
7、SASdiskshelvesandSASopticalcablesdocument.Note:Cablinginformationforhot-addingorreplacingSASdiskshelvesisintheInstallationandSerViCeGuideforyourdiskshelfmodel.AlldocumentscanbefoundontheNetAppSupportSSAScablingrulesYoucancableSASdiskshelvestostoragesystemsthathaveSASHBAsand/oronboardSASportsbyapplyi
8、ngtheSAScablingrules.GeneralSAScablingrulesYouneedtoknowthegeneralSAScablingmlesgoverningsupportedconfigurations,cables,andSASportconnectionsonthediskshelves.AllHApairconfigurationsmustusemultipathHA,withthefollowingexceptions:FAS2040systemsusesingle-pathHA.FAS22xxsystemswithnoexternalSASstoragecanu
9、sesingle-pathHA,whichrequiresnoexternalcabling.However,therecommendedconfigurationistoenablemultipathHfortheinternaldisksbyconnectingtheSASportsofonecontrollermoduletotheSASportsofthepartner.Note:AmultipathHAconfigurationhavingexternalshelvesrequirestwoportsoneachcontrollerforeachstackofdiskshelves.
10、EvenifthestackconsistsofonediskShe优twoportsoneachcontrollerarerequired.Allsingle-controllerconfigurationsmustusedual-path,withthefollowingexceptions:FAS2040systemsusesingle-path. FAS22xxsystemshavetheinternaldiskscabledassingle-path,butthesystemcanuseeithersingle-pathordual-pathconnectivitytotheexte
11、rnalshelves;botharesupported.Dual-pathprovidesgreaterresiliency,butwhendual-pathisused,DataONTAP8.1.xissuesoccasionalwarningstotheconsolebecausemixedpathsaredetected.Toavoidthewarnings,single-pathconnectionstotheexternalSASstorageareasupportedoptionintheseconfigurations.OnlyMetroClustersystemswithdi
12、skshelvesdirectlyattachedtothecontrollerscanuseSASopticalcables.Forexample,MetroClustersystemsusingFibreBridge6500NbridgesuseSAScoppercables.TheSAScablescanbeSAScopper,SASoptical,oramixdependingonwhetherornotyoursystemmeetstherequirementsforusingthetypeofcable.IfyouareusingamixofSAScoppercablesandSA
13、Sopticalcables,thefollowingrulesapply:Shelf-to-shelfconnectionsinastackmustbeallSAScoppercablesorallSASopticalcables.Iftheshelf-to-shelfconnectionsareSASopticalcables,theshelf-to-controllerconnectionstothatstackmustalsobeSASopticalcables. Iftheshelf-to-shelfconnectionsareSAScoppercables,theshelf-to-
14、controllerconnectionstothatstackcanbeSASopticalcablesorSAScoppercables.ThecableQSFPconnectorendconnectstoadiskshelforaSASportonacontroller.TheSAScableQSFPconnectorsarekeyed;whenorientedcorrectlyintoaSASport,theQSFPconnectorclicksintoplaceandthediskshelfSASportLNKLEDilluminatesgreen.Donotforceaconnec
15、torintoaport.ThefollowingillustrationshowsaQSFPconnector:Note:TheQSFPconnectorshownhasapulltabforreleasingtheconnectorfromaSASport;however,QSFPconnectorscanhaveadifferentreleasemechanism.DiskshelvesconnectedwithSASopticalcablesrequireaversionofdiskshelffirmwarethatsupportsSASopticalcables.Bestpracti
16、ceistoupdatealldiskshelvesinthestoragesystemwiththelatestversionofdiskshelffirmware.Note:DonotrevertdiskshelffirmwaretoaversionthatdoesnotsupportSASopticalcables.SASopticalmultimodeQSFP-to-QSFPcablescanbeusedforcontrollcr-to-shelfandshelf-to-shelfconnections,andareavailableinlengthsupto50meters.Ifyo
17、uareusingSASopticalmultimodeMPOcableswithMPOQSFPmodules,thefollowingparametersapply: Youcanusethesecablesforcontroller-to-shelfandshelf-to-shelfconnections. Thelengthofasinglecablecannotexceed150metersfor0M4and100metersforOM3.Thetotalend-to-endpath(sumofpoint-to-pointpathsfromthecontrollertothelasts
18、helf)cannotexceed510meters.Thetotalpathincludesthesetofbreakoutcables,patchpanels,andinter-panelcables.IfyouareusingSASopticalmultimodebreakoutcables,thefollowingparametersapply:Youcanusethesecablesforcontroller-to-shelfandshelf-to-shelfconnections.Ifyouusemultimodebreakoutcablesforashelf-to-shelfco
19、nnection,youcanonlyuseitoncewithinastackofdiskshelves.YoumustuseSASopticalmultimodeQSFP-to-QSFPorMPOcableswithMPOQSFPmodulestoconnecttheremainingshelf-to-shelfconnections. Thepoint-to-point(QSFP-to-QSFP)pathofanymultimodecablecannotexceed150metersforOM4and100metersforOM3.Thepathincludesthesetofbreak
20、outcables,patchpanels,andinter-panelcables. Thetotalend-to-endpath(sumofpoint-to-pointpathsfromthecontrollertothelastshelf)cannotexceed510meters.Thetotalpathincludesthesetofbreakoutcables,patchpanels,andinter-panelcables. Uptoonepairofpatchpanelscanbeusedinapath. Youneedtosupplythepatchpanelsandinte
21、r-panelcables.Theinter-panelcablesmustbethesamemodeastheSASopticalbreakoutcable:multimode. YoureceivedasetofQSFP-to-MPOcablemoduleswitheachsetofSASopticalbreakoutcables,whichyoumustattachtotheMPOendofeachSASopticalbreakoutcable.ThebreakoutcableshaveSC,LC,orMTRJconnectorsontheoppositeend,whichconnect
22、toapatchpanel. Youmustconnectalleight(fourpairs)oftheSC,LC,orMTRJbreakoutconnectorstothepatchpanel.IfyouareusingSASopticalsinglemodebreakoutcables,thefollowingparametersapply:Note:SASopticalsinglemodebreakoutcablescanonlybeusedinMetroClustersystems. Youcanusethesecablesforcontroller-to-shelfconnecti
23、ons.Shelf-to-shelfconnectionsusemultimodeQSFP-to-QSFPcablesormultimodeMPOcableswithMPOQSFPmodules. Thepoint-to-point(QSFP-to-QSFP)pathofasinglesinglemodecablecannotexceed500meters. Thetotalend-to-endpath(sumofpoint-to-pointpathsfromthecontrollertothelastshelf)cannotexceed510meters.Thetotalpathinclud
- 配套讲稿: