ISO 19396-2 2025.docx
《ISO 19396-2 2025.docx》由会员分享,可在线阅读,更多相关《ISO 19396-2 2025.docx(16页珍藏版)》请在三一文库上搜索。
1、ISOInternationalStandardISO19396-2Secondedition2025-06Paintsandvarnishes一DeterminationofpHvalue一Part2:pHsensorswithISFETtechnologyPeinturesetvernisDeterminationdeIavaleurdepHPartie2:SondesdepHdoteesdeIatechnologieISFETReferencenumberISO19396-2:2025(en)COPYRIGHTPROTECTEDDOCUMENTISO2025Allrightsreserv
2、ed.Unlessotherwisespecified,orrequiredinthecontextofitsimplementation,nopartofthispublicationmaybereproducedorutilizedotherwiseinanyformorbyanymeans,electronicormechanical,includingphotocopying,orpostingontheinternetoranintranet,withoutpriorwrittenpermission.PermissioncanberequestedfromeitherISOatth
3、eaddressbeloworISO,smemberbodyinthecountryoftherequester.ISOcopyrightofficeCP401Ch.deBlandonnet8CH-1214Vernier,GenevaPhone:+41227490111Email:copyrightiso.orgWebsite:www.iso.orgPublishedinSwitzerlandContentsPageForewordivIntroductionv1 Scope12 Normativereferences13 Termsanddefinitions14 Principle45 A
4、pparatusandmaterials45.1 pHmeasuringapparatus45.2 pHmeter45.3 ISFETsensor55.4 Buffersolutions66 Sampling67 Procedure77.1 Testconditions77.2 Calibration77.3 Numberofdeterminations77.4 MeasuringthepHvalue78 Evaluation79 Precision89.1 General89.2 Repeatabilitylimit,r89.3 Reproducibilitylimit,R810 Testr
5、eport8AnnexA(informative)Determinationofprecision9Bibliography11ForewordISO(theInternationalOrganizationforStandardization)isaworldwidefederationofnationalstandardsbodies(ISOmemberbodies).TheworkofpreparingInternationalStandardsisnormallycarriedoutthroughISOtechnicalcommittees.Eachmemberbodyinterest
6、edinasubjectforwhichatechnicalcommitteehasbeenestablishedhastherighttoberepresentedonthatcommittee.Internationalorganizations,governmentalandnon-governmental,inliaisonwithISO,alsotakepartinthework.ISOcollaboratescloselywiththeInternationalElectrotechnicalCommission(IEC)onallmattersofelectrotechnical
7、standardization.TheproceduresusedtodevelopthisdocumentandthoseintendedforitsfurthermaintenancearedescribedintheISO/IECDirectives,Part1.Inparticular,thedifferentapprovalcriterianeededforthedifferenttypesofISOdocumentshouldbenoted.ThisdocumentwasdraftedinaccordancewiththeeditorialrulesoftheISO/IECDire
8、ctives,Part2(seeWWW.iso.org/directives).ISOdrawsattentiontothepossibilitythattheimplementationofthisdocumentmayinvolvetheuseof(八)patent(三).ISOtakesnopositionconcerningtheevidence,validityorapplicabilityofanyclaimedpatentrightsinrespectthereof.Asofthedateofpublicationofthisdocument,ISOhadnotreceivedn
9、oticeof(八)patent(三)whichmayberequiredtoimplementthisdocument.HoweverlImplementersarecautionedthatthismaynotrepresentthelatestinformation,whichmaybeobtainedfromthepatentdatabaseavailableatWWW.iso.org/patents.ISOshallnotbeheldresponsibleforidentifyinganyorallsuchpatentrights.Anytradenameusedinthisdocu
10、mentisinformationgivenfortheconvenienceofusersanddoesnotconstituteanendorsement.Foranexplanationofthevoluntarynatureofstandards,themeaningofISOspecifictermsandexpressionsrelatedtoconformityassessment,aswellasinformationaboutISOsadherencetotheWorldTradeOrganization(WTO)principlesintheTechnicalBarrier
11、stoTrade(TBT),seeWWW.iso.org/iso/foreword.htmLThisdocumentwaspreparedbyTechnicalCommitteeISO/TC35,Paintsandvarnishes,SubcommitteeSC9,Generaltestmethodsforpaintsandvarnishes,incollaborationwiththeEuropeanCommitteeforStandardization(CEN)TechnicalCommitteeCEN/TC139,Paintsandvarnishes,inaccordancewithth
12、eAgreementontechnicalcooperationbetweenISOandCEN(ViennaAgreement).Thissecondeditioncancelsandreplacesthefirstedition(ISO19396-2:2017),whichhasbeentechnicallyrevised.Themainchangesareasfollows: definitionsforntheoreticalslopeandstabilityofmeasuredvalue“havebeendeleted; theterm,ISFETelectrode11hasbeen
13、changedtor,ISFETsensorintheentiretextincludingthetitleofthedocument; thecalibrationf7.2hasbeenclarified; thenormativereferenceshavebeenupdated.AlistofallpartsintheISO19396seriescanbefoundontheISOwebsite.Anyfeedbackorquestionsonthisdocumentshouldbedirectedtotheusersnationalstandardsbody.Acompletelist
14、ingofthesebodiescanbefoundatWWW.iso.org/membnrs.htmLIntroductionThepHvalueofaqueousproductsisofdecisiveimportancefortheproductpropertiesanddurability.ISO19396-1specifiesamethodformeasuringthepHvalueusingpHsensorswithaglassmembrane.ThisdocumentcoversamethodformeasuringthepHvalueofdispersionsandcoatin
15、gmaterialsusingpHsensorswithion-sensitivefield-effecttransistor(ISFET)technology.PaintsandvarnishesDeterminationofpHvalue一Part2:pHsensorswithISFETtechnology1 ScopeThisdocumentspecifiesamethodformeasuringthepHvalueofdispersionsandcoatingmaterialsusingpHsensorswithion-sensitivefield-effecttransistor(I
16、SFET)technology.2 NormativereferencesThefollowingdocumentsarereferredtointhetextinsuchawaythatsomeoralloftheircontentconstitutesrequirementsofthisdocument.Fordatedreferences,onlytheeditioncitedapplies.Forundatedreferences,thelatesteditionofthereferenceddocument(includinganyamendments)applies.ISO1513
17、PaintsandvarnishesExaminationandpreparationOftestsampIesISO4618,PaintsandvarnishesVocabularyISO15528,Paints,varnishesandrawmaterialsforpaintsandvarnishesSamplingISO80000-9,QuantitiesandunitsPart9:Physicalchemistryandmolecularphysics3 TermsanddefinitionsForthepurposesofthisdocument,thetermsanddefini
18、tionsgiveninISO4618,ISO80000-9andthefollowingapply.ISOandIECmaintainterminologydatabasesforuseinstandardizationatthefollowingaddresses: ISOOnlinebrowsingplatform:availableathttps:/www.iso.org/ObP IECElectropedia:availableathttps:WWW.electropedia.org/3.1PHmeasurefortheacidicorbasicreactionofanaqueous
19、solutionorpolymerdispersionNote1toentry:ForthenotationOfPH,thePandtheHareverticallyononeline.ThesameisvalidforpOH.Note2toentry:Theacidicreactionisdeterminedbytheactivityoftheexisting11hydrogenions”.Thebasicreactionisdeterminedbytheactivityoftheexistinghydroxideions.Thedirectrelationshipbetweentheact
20、ivitiesofthe“hydrogenionsandthehydroxideionsisdescribedbytheionicproductofthewater.SOURCE:ISO19396-1:2025,3.13.2pHvaluedecadallogarithmofthehydrogenionactivitymultipliedwith(-1)Qp=%+7h+wherea+istheactivityofthehydrogenion,inmol/kg;m0isthestandardmolality(1molkg);h+istheactivitycoefficientofthehydrog
21、enion;isthemolalityofthehydrogenion,inmolkg.Note1toentry:ForfurtherdetailsseeDIN19261.SOURCE:ISO19396-1:2025,3,23.3ISFETsensorion-sensitivefield-effecttransistorsensorcombinedpHsensorwithISFETtechnologypotentiometriccellprovidingavoltagewhichdependsonthepHvalue(3.2)ofthemeasuringmediumNote1toentry:T
22、hetwoelectrochemicalcellsaretheion-sensitivefield-effecttransistor(ISFET)(3.5)andthereferenceelectrode(3.4).1 referenceelectrode,consistingof2,3and42 referenceelement3 referenceelectrolyte4 diaphragm5 pHmeasuringsensor,consistingof6and76 ISFET(seeFigure4)7 openingtothemeasuringmediumgate8 temperatur
23、esensorUpHproportionalvoltageUDSvoltagereceiver/sender(drain/source)7dscurrentreceiver/sender(drain/source)Figure1DesignofanISFETsensor(schematicdiagram)3.4referenceelectrodeelectrodeprovidingaconstantpotentialWhichisindependentfromXhepHvalue(3.2)ofthemeasuringmediumNote1toentry:Atthetimeofpublicati